Flagstaff outdoor lighting code — what a site-lighting design must meet

Outdoor lighting code · transcribed from adopted text · verified August 8, 2026

Flagstaff is the one Arizona code that tells you what color the light must be before it tells you how much of it you may have. Every number below comes from Flagstaff Zoning Code Table 10-50.70.050.B (Ord. 2022-27 as amended by Ord. 2026-01), the same rule file our Lighting Design Tool computes with — nothing retyped. Ordinances change: confirm current requirements with the authority having jurisdiction before submittal.

Flagstaff regulates outdoor lighting with a lumen budget per net acre by zone plus a source mandate: narrow-spectrum amber LED for general lighting, white light only for listed uses. The at-a-glance table is the code’s own table, reproduced; everything after it is the rule text that changes a design.

At a glance: lumen budget per net acre

Lumen budget per net acre by lighting area and code option
Commercial / industrial / multifamily (Table 10-50.70.050.B)
Lighting areaTotal lm/acreUnshielded lm/acre
Z117,5000
Z235,0003,850
  • Commercial / industrial / multifamily (Table 10-50.70.050.B): Combined maximum of fully + partially shielded fixtures per net acre. LED screw-in bulbs and all non-LED lamps count at 70% of rated lumens; recessed-under-canopy fixtures get distance-based discounts.
  • Commercial / industrial / multifamily (Table 10-50.70.050.B) — Freestanding (not building/canopy-mounted) portion is capped at Z1 4,000 · Z2 35,000 lm/acre.
  • n/a means the adopted table has no value for that area and option — the option is not available there, or it was not transcribed; the Lighting Design Tool refuses to compute a budget from it. 0 is a real zero allowance.

The limits behind the table

2700KMaximum color temperature, general outdoor lighting
2700KMaximum color temperature, internally illuminated signs
1,750 lmLargest single unshielded fixture
Z1 ≤15 · Z2 ≤30 lm/ft²Canopy illumination cap (lumens per ft² of canopy)
2Lighting areas: Z1, Z2

Which lighting area is the site in?

Zone 1 = within 2.5 miles of the Kaj Strand telescope at the U.S. Naval Observatory; Zone 2 = everywhere else in the city. Split parcels take the more restrictive zone. Budgets below are the COMMERCIAL/industrial/multifamily table (per net acre); single-family homes use small per-LOT budgets instead (Z1: 1,500 lm/lot · Z2: 5,000 lm/lot) — see the permit worksheet.

Shielding and light trespass

Direct illumination confined to the property; any fixture over 10,000 lumens within 50 ft of residential or right-of-way needs an internal or black-painted external shield. Upward-aimed architectural/landscape lighting prohibited; partially shielded fixtures ≥1,750 lumens prohibited.

Color temperature

Flagstaff's default for general/security/parking lighting (Class 2) is NARROW-SPECTRUM AMBER LED (peak 589–595 nm) — regular white LED is not allowed for those uses. White light ≤2700K (Class 1) is allowed only for specific uses: outdoor sales, primary customer entries, outdoor dining, work areas, recreation fields, and signs. Decorative Class 3 lighting may use any source under strict lumen limits. Internally illuminated signs are limited to 2700K.

Curfews and controls

  • Class 1 and Class 3 lighting, and Class 2 lighting more than 50 ft from any structure/display/storage area, OFF within 30 minutes of close of business until reopening.
  • Outdoor sports facilities: off by 9:00 PM in Zone 1 / 11:00 PM in Zone 2 (may finish an event in progress).
  • Motion-sensing fixtures: fully shielded, auto-off within 5 minutes.

Canopies

Service-station canopies: ≤15 lm/ft² of canopy in Zone 1, ≤30 in Zone 2.

Signs

Internally illuminated sign lamps are excluded from the lumen budget; sign lighting is a Class 1 use (≤2700K). Internally illuminated signs are exempt from the lumen budget.

What the permit submittal must show

Flagstaff requires an Outdoor Lighting Permit ($130): lumen-calculation tables (existing + proposed), Total Outdoor Light Output worksheet, a lighting plan keyed to the fixture schedule, and cut sheets — Class 2 cut sheets must state the amber peak wavelength with a spectral graph.

The trap that catches out-of-town designers

Flagstaff's default source for parking, security and general area lighting (Class 2) is narrow-spectrum amber LED with its peak between 589 and 595 nm — ordinary white LED is not permitted for those uses, and the cut sheets must state the amber peak wavelength with a spectral graph. White light up to 2700K (Class 1) is allowed only for listed uses: outdoor sales, primary customer entries, outdoor dining, work areas, recreation fields and signs. The budgets are small: 35,000 lumens per net acre in Zone 2 and 17,500 in Zone 1 (within 2.5 miles of the Naval Observatory's Kaj Strand telescope), and in Zone 1 only 4,000 of that may be freestanding. Screw-in LED and all non-LED lamps count at 70% of rated lumens; a partially shielded fixture of 1,750 lumens or more is prohibited; anything over 10,000 lumens within 50 ft of residential or a right-of-way needs an internal or black-painted shield; and Class 1 and Class 3 lighting goes off within 30 minutes of close. It all runs through a $130 Outdoor Lighting Permit.

Underneath every city code: the state statute

  • Arizona statute: every outdoor light fixture must be fully or partially shielded unless it is an incandescent lamp of 150 W or less, or any other lamp of 70 W or less (ARS §49-1102).
  • Mercury-vapor fixtures may not be sold or installed anywhere in Arizona (ARS §49-1104).

The statute is the floor; the city or town ordinance above is what the permit is reviewed against. Where the two differ, the stricter applies.

Source, date and limits

Source: Flagstaff Zoning Code Table 10-50.70.050.B (Ord. 2022-27 as amended by Ord. 2026-01). Transcribed and verified: August 8, 2026, from the code text itself, never a summary site. Page updated: 5 September 2026. Status: current as of the verification date.

These pages render the same data file that drives our Lighting Design Tool, so a value here is the value the tool checks a design against. They are a reference, not a code book and not legal advice: the adopted ordinance, its amendments and the reviewer’s interpretation govern. Confirm with the authority having jurisdiction before you submit. IES illuminance targets and IECC power allowances are licensed-standard material and are not reproduced here.

Questions people ask

What kind of light source does Flagstaff require for parking and area lighting?

Flagstaff's default for general/security/parking lighting (Class 2) is NARROW-SPECTRUM AMBER LED (peak 589–595 nm) — regular white LED is not allowed for those uses. White light ≤2700K (Class 1) is allowed only for specific uses: outdoor sales, primary customer entries, outdoor dining, work areas, recreation fields, and signs. Decorative Class 3 lighting may use any source under strict lumen limits. Internally illuminated signs are limited to 2700K.

How many lumens per acre does Flagstaff allow?

Under Flagstaff Zoning Code Table 10-50.70.050.B (Ord. 2022-27 as amended by Ord. 2026-01), the Commercial / industrial / multifamily (Table 10-50.70.050.B) allows Z1 17,500 · Z2 35,000 lumens per net acre of developed site by lighting area. Of that, unshielded fixtures may account for at most Z1 0 · Z2 3,850 lumens per acre.

When must outdoor lighting be off in Flagstaff?

Class 1 and Class 3 lighting, and Class 2 lighting more than 50 ft from any structure/display/storage area, OFF within 30 minutes of close of business until reopening. Outdoor sports facilities: off by 9:00 PM in Zone 1 / 11:00 PM in Zone 2 (may finish an event in progress). Motion-sensing fixtures: fully shielded, auto-off within 5 minutes.

What does a Flagstaff Outdoor Lighting Permit require?

Flagstaff requires an Outdoor Lighting Permit ($130): lumen-calculation tables (existing + proposed), Total Outdoor Light Output worksheet, a lighting plan keyed to the fixture schedule, and cut sheets — Class 2 cut sheets must state the amber peak wavelength with a spectral graph.

Design to this code

Site lighting design-build