Dietz: permit history and electrical signals

City of Tucson neighborhood in Ward 4 — north: 22nd Street, east: Pantano Parkway, south: Golf Links Road, west: Kolb Road. What the public record says about how old the houses are, what has been permitted since 2022, and what that usually means electrically — measured from the City’s own GIS layers, not estimated.

Dietz by the numbers

1,144homes with a published build year
1965median year builtoldest 1950 · newest 2009
69%built before 1974
227permits since Jan 202219.8 per 100 homes vs 20.2 across Tucson’s 140 registered neighborhoods
22panel / service upgrade permitssince 2022
26HVAC changeout permitssince 2022
21solar permitssince 2022
5remodel / addition permitssince 2022
13electrical code-enforcement casesof 433 cases opened since 2022

Among the 12 neighborhoods in this hub, Dietz ranks 4th for permit activity per home since 2022, 7th for panel and service upgrades per home (1.9 per 100 homes with a build year), and 10th for the share of pre-1974 housing.

Counts are City of Tucson GIS permit layers 85 (residential), 81 (commercial) and 102 (code enforcement) inside the neighborhood boundary, issued or opened on or after 1 January 2022 — the window those layers cover. Older permits exist in the City’s Property Research Online file and show up in the per-address report. Build years are the assessor’s published values, which stop at 2009. “Per 100 homes” divides by homes with a published build year; the comparison figure uses the same measure summed over the City’s 140 registered neighborhoods, not every parcel in the city.

When Dietz was built

  • Before 19500%
  • 1950–196448%
  • 1965–197322%
  • 1974–198917%
  • 1990–19955%
  • 1996–20078%
  • 2008 or later0%

Highlighted bands are the eras that carry a known wiring or panel issue in Tucson housing.

Post-war services and ungrounded circuits

About 48% went up between 1950 and 1964 — Tucson's post-war boom. Services from those years were 60 to 100 amps, often a fuse panel since swapped for breakers without the service itself ever being enlarged. Grounded branch circuits did not become the norm until the early 1960s, and the cloth jacket on that era's cable embrittles in a Tucson attic. That is the 5th-largest share of the 12 neighborhoods in this hub.

Aluminum branch-circuit wiring

Roughly 22% went up between 1965 and 1973 — the window when solid aluminum was used for 15 and 20 amp branch circuits. The wire itself is not the problem; the terminations are, and the accepted repairs are COPALUM crimps or AlumiConn connectors. A wire nut is not a repair. That is the 2nd-largest share of the 12 neighborhoods in this hub.

Federal Pacific and Zinsco panels

About 17% of the stock dates to 1974–1989, when Federal Pacific Stab-Lok and Zinsco/Sylvania panels were still being installed. Both have documented failure-to-trip histories in the breaker-to-bus connection itself, so a new breaker does not resolve it — the panel is what gets replaced once you need to add a circuit. That is the 2nd-largest share of the 12 neighborhoods in this hub.

Permit activity by year

YearAll permitsPanel / service upgrades
2022455
2023684
2024202
2025498
2026 (to date)453

Recent permits worth noticing in Dietz

  • hvac2026-07-22 · TC-RES-0726-03718 — HVAC new A/C installed, removed evap, rooftop condenser with gas furnace.
  • hvac2026-07-06 · TC-RES-0626-03511 — *URGENT/EMERGENCY NEED* Customer elected to have HVAC system replaced as opposed to repairing existing system. Replace
  • hvac2026-07-06 · TC-RES-0626-02927 — *URGENT/EMERGENCY NEED* Customer elected to have HVAC system replaced as opposed to repairing existing system. Replac
  • hvac2026-06-29 · TC-RES-0626-03496 — Installation of new 1 ton mini split heat pump, condenser on roof.
  • hvac2026-06-10 · TC-RES-0626-03029 — HVAC REPLACEMENT: SWAPPING OLD 4-TON MOBILE HOME SPLIT SYSTEM WITH A NEW 5-TON MOBILE HOME SPLIT SYSTEM
  • solar2026-06-01 · TC-RES-0426-02162 — 4.100 kW DC Roof Mounted Solar + Battery and Derate with existing system
  • solar2026-06-01 · TC-RES-0526-02420 — INSTALLATION OF (N) 01 - TESLA POWERWALL 3 BATTERY ESS.
  • remodel2026-05-05 · TC-COM-0426-00480 — Replace existing SES with new 1200A 3PH 120/240v SES. Please see sheet E2 of attached drawings. This is in addition to o

Permit number, date, type and the City’s own description — nothing else. Each links to the official record.

Example property reports in Dietz

Real parcels in the neighborhood with a permit history deep enough to read. Each opens the full report.

Look up an address in Dietz

Any address in Pima County works. You get the parcel, the year built, the full permit history (City file back to about 2006), the code cases, and what each system’s record implies — plus an AI read of the whole record and of the plan sheets behind a City permit.

What we do with this in Dietz

In Dietz the record since 2022 shows 22 permitted panel or service upgrades since 2022 (7th of 12 per home), 26 HVAC changeouts, 5 remodels or additions, 21 solar installs across 1,144 homes with a build year — mixed-era housing where the panel, the service and the branch wiring are usually the first questions. Arizona Electrical Solutions holds four ROC licenses (electrical CR‑11, HVAC CR‑39, general building KB‑1, general engineering KA), all Dual, so the same crew can do the panel, the circuits and the mechanical side.

Other neighborhoods in the hub: Sam Hughes · Armory Park · Blenman-Elm · Palo Verde · La Madera · Corbett · Sunnyside · Colonia Del Valle · West University · Campbell-Grant Northeast · Myers · all neighborhoods.