Electrical permit history — 7366 N Paseo Del Norte

7366 N Paseo Del Norte, Oro Valley — built 1937, with 10 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

7366 N Paseo Del Norte

Built 1937 — 1930s commercial stock · 10 permits on record; no permitted panel/service or HVAC work among them

Parcel
22514237D
Built
1937 (assessor record)
Jurisdiction
Oro Valley
Zoning
PAD
Assessor use
Club Lodge Or Fraternal Organization
Parcel size
48.63 acres
Building area
22,114 sq ft (assessor record)
Sewer
Connection on file (2003, 2006, 2013) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)

See the property

County aerial photograph centered on 7366 N Paseo Del Norte, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2019 solar pv permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2019 solar pv permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. This parcel is in the Town of Oro Valley, so we read the town’s own SmartGov permit portal alongside the regional records. Every town record links to its official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    Solar was permitted here in 2019. That means there is an existing interconnection, and the main breaker and busbar rating already carry a PV backfeed — so anything else you add (an EV charger, a heat pump) has to be checked against what is left under the 120% rule, not against the service size alone.

  • Routine

    A trade permit was pulled in 2023. Trade permits cover electrical, plumbing, and mechanical work individually, so some permitted trade work has been done here since.

Most recent permit on record for this parcel: 2026-07-28 (2601444).

Permit history (10)

Permit history for this parcel — 8 of 10 records
DateRecordWhatStatusValue
2026-07-282601444Oro Valley permitOther or Misc (construction trailers, alterations not related to MP&E trades, shade structures, sports courts)Permit Issued
2023-09-222302135Oro Valley permitRight-of-Way Use (storage containers, special events, etc.)Permit Issued
2023-06-20finaled2300011Oro Valley permitTrade permitClosed / COO
2022-07-08OV1701902Oro Valley permitSite Design Review (Site and Landscape Plans)Application Closed
2022-07-07OV1500812Oro Valley permitConditional Use PermitApplication Closed
2019-04-30finaled1901005Oro Valley permitSolar PVFinaled
2018-10-05finaledC1802739Oro Valley permitNew BuildingClosed / COO
2017-08-16finaledG1702003Oro Valley permitType 2 Grading (Subdivision & Commercial Development)Finaled
Show 2 older records
Permit history for this parcel — remaining 2 records
DateRecordWhatStatusValue
2016-10-17finaledMB1602784Oro Valley permitTrade permitFinaled
2016-07-27finaledMB1601823Oro Valley permitSolar PVFinaled

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Showing the 10 most recent town records — this parcel has more. The full set is on the Town of Oro Valley’s permit portal (search the parcel number, no dashes).

Record numbers link to the issuing office’s official file — the Town of Oro Valley’s portal for town permits. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 22514237D — 10 permits on file from 2016 to 2026 (2 trade permit, 2 solar pv, 1 other or misc (construction trailers, alterations not related to mp&e trades, shade structures, sports courts), 1 right-of-way use (storage containers, special events, etc.)) — assembled from the Pima County parcel file, the City of Tucson GIS layers, and the Town of Oro Valley’s SmartGov permit portal. Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.