Electrical permit history — 2070 W Rudasill Rd

2070 W Rudasill Rd, Tucson — built 1998, with 24 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

2070 W Rudasill Rd

Built 1998 — 1990s commercial stock · 24 permits on record; no permitted panel/service or HVAC work among them

Parcel
10213010D
Built
1998 (assessor record)
Jurisdiction
Unincorporated Pima County
Zoning
TR
Assessor use
Medical Clinic No Pharmacy
Parcel size
1.43 acres
Building area
15,550 sq ft (assessor record)
Sewer
Connection on file (2001, 2005, 2008) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)

See the property

County aerial photograph centered on 2070 W Rudasill Rd, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 building permit is on file — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 building permit is on file — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. This parcel is in unincorporated Pima County, so we read the county’s own permit system — including its historical permits, which reach back into the 1990s where they exist. Every record links to the county’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    Gear in this age range is usually still supported but is due for infrared scanning and torque verification if that has not been done recently. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Routine

    Office and medical tenant improvements are usually limited by available panel spaces and branch circuit capacity, not by the service itself.

Recorded sales (1)

Recorded transfers from the Pima County Assessor — 1 of 1
DatePriceType
2014-05-01$4,291,776Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2026-03-31 (P26BP02156) — Sign — TMC Healthcare.

Permit history (24)

Permit history for this parcel — 8 of 24 records
DateRecordWhatStatusValue
2026-03-31finaledP26BP02156Pima County permitOther StructuresSign — TMC HealthcareFinal
2026-02-03finaledP26RW00168Pima County permitRight of WayRUDASILL - La Cholla Blvd and Rusasill RdFinal
2025-05-13finaledP25RR00102Pima County permitPublic Records Request2070 W Rudasill Rd CofO ReprintComplete
2025-04-01finaledP25BP02630Pima County permitBuildingTenant ImprovementC of O
2025-02-26P25BP01593Pima County permitDamage/DemoPermit Expired
2025-02-19finaledP25BP01404Pima County permitOther StructuresSignFinal
2024-08-22finaledP24RW01134Pima County permitRight of WayRUDASILL - W Rudasill & N La ChollaFinal
2015-08-10finaledP15RW01243Pima County permitRight of WayROW / RTEL - LINDA JOHNSON — N SILVERBELL RDFinal
Show 16 older records
Permit history for this parcel — remaining 16 records
DateRecordWhatStatusValue
2015-06-22finaledP15CP04101Pima County permitOther StructuresCOMBO/SIGN -Final
2008-09-03finaledP08CP06565Pima County permitHistoricalSIGN/SIGN - — DP 16/95Final
2008-09-03finaledP08CP06564Pima County permitHistoricalSIGN/SIGN - — DP 16/95Final
2007-10-29finaledP07CP09929Pima County permitHistoricalCOMBO/CTI - — DP 16/95C of O
2004-11-09finaledP04CP12488Pima County permitHistoricalCOMBO/CTI - — FOUNTAINS PLAZA DP 16/95C of O
2004-11-09finaledP04CP12487Pima County permitHistoricalCOMBO/CTI - — FOUNTAIN PLAZA DP 16/95C of O
2004-10-05finaledP04CP11162Pima County permitHistoricalCOMBO/CTI - — FOUNTAIN PLAZA DP 26/95C of O
2001-03-08finaledP01CP02350Pima County permitHistoricalCOMBO/CTI -C of O
1998-08-26P98CP08422Pima County permitHistoricalCOMBO/CADD - — FOUNTAINS PLAZAExpired
1998-08-03finaledP98CP07589Pima County permitHistoricalCOMBO/CTI - — THE FOUNTAINS AT LA CHOLLAFinal
1998-07-23P98CP07298Pima County permitHistoricalCOMBO/CADD - — FOUNTAINS AT LA CHOLLAExpired
1998-07-21P98CP07161Pima County permitHistoricalPLUMB/COTH - — FOUNTAINS PLAZAExpired
1998-06-12P98CP05832Pima County permitHistoricalBUILD/CADD - — FOUNTAINS PLAZA BLDG. #3Expired
1998-02-10finaledP98CP01287Pima County permitHistoricalCOMBO/CTI - — FOUNTAINS PLAZAC of O
1998-02-10finaledP98CP01288Pima County permitHistoricalCOMBO/CTI - — FOUNTAINS PLAZAC of O
1998-02-10finaledP98CP01277Pima County permitHistoricalCOMBO/CNEW - — FOUNTAINS PLAZAFinal

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Record numbers link to the issuing office’s official file — Pima County’s portal for county permits, the City of Tucson’s for city records. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 10213010D — 24 permits on file from 1998 to 2026 (15 historical, 3 other structures, 3 right of way, 1 public records request) — assembled from the Pima County parcel file, the City of Tucson GIS layers, and Pima County’s Accela permit portal (searched by parcel and by address, because the county’s parcel links break on older records). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.