Electrical permit history — 1919 W Medical St

1919 W Medical St, Tucson — built 1983, with 31 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

1919 W Medical St

Built 1983 — 1980s commercial stock · 31 permits on record; no permitted panel/service or HVAC work among them

Parcel
102120880
Built
1983 (assessor record)
Jurisdiction
Unincorporated Pima County
Zoning
SR
Assessor use
Nursing/Orphan/Rehab Profit Registered
Parcel size
9.93 acres
Building area
65,294 sq ft (assessor record)
Sewer
Connection on file (1997) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)

See the property

County aerial photograph centered on 1919 W Medical St, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 building permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 building permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. This parcel is in unincorporated Pima County, so we read the county’s own permit system — including its historical permits, which reach back into the 1990s where they exist. Every record links to the county’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

Recorded sales (1)

Recorded transfers from the Pima County Assessor — 1 of 1
DatePriceType
2014-05-01$10,125,000Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2026-08-12 (P26BP05392) — Commercial Building Other — Casas Adobes rehab.

Permit history (31)

Permit history for this parcel — 8 of 31 records
DateRecordWhatStatusValue
2026-08-12P26BP05392Pima County permitBuildingCommercial Building Other — Casas Adobes rehabIn Review
2026-07-06finaledP26RR00183Pima County permitPublic Records RequestDSD:Complete
2025-10-30finaledP25BP08188Pima County permitBuildingTenant Improvement — CasasC of O
2025-08-05P25BP02990-01Pima County permitAddition / alterationCommercial Building Alteration - RevisionApproved
2025-04-16P24BP09483-01Pima County permitAddition / alterationCommercial Building Alteration - RevisionApproved
2025-04-14finaledP25BP02990Pima County permitAddition / alterationCommercial Building AlterationFinal
2024-10-30finaledP24BP09483Pima County permitAddition / alterationCommercial Building AlterationC of O
2024-09-24expired 2025-03-23TC-COM-0924-01852City permit recordFence / wall**VOID: YL- UNABLE TO PROCESS. THE ADDRESS APPLIED FOR IS OUTSIDE CITY LIMITS. PROPERTY IS IN PIMA COUNTY JURISDICTION. FOR MORE INFORMATION YOU CAN REACH PIMA COUNTY DEVELOPMENT SERVICES 520-724-6490 ** -Remodeling a current shower room into a new conference room. Creating a new shower room and making a patient area a new lobby. Lastly, creating a new CMU wall for patient containment.Void
Show 23 older records
Permit history for this parcel — remaining 23 records
DateRecordWhatStatusValue
2022-10-31P22BP06692-01Pima County permitRevisionTenant Improvement - RevisionApproved
2022-06-07P22BP06692Pima County permitBuildingTenant ImprovementPermit Expired
2020-09-01finaledP20RR00157Pima County permitPublic Records RequestPRR2009-01Complete
2020-08-21P20RR00146Pima County permitPublic Records Requestzvl- Bureau Veritas- W. Medical StreetWithdrawn
2015-05-27finaledP15CP03358Pima County permitBuildingCOMBO/COTH -Final
2015-03-24finaledP15CP01827Pima County permitBuildingCOMBO/COTH -Final
2013-02-06finaledP13CP00688Pima County permitBuildingCOMBO/COTH -Final
2012-02-16finaledP12CP00952Pima County permitC of O HistoricalCOMBO/COFO -C of O
2011-05-31finaledP11CP03501Pima County permitOther StructuresCOMBO/SIGN - — DP 2/18Final
2011-05-27P11CP03445Pima County permitOther StructuresCOMBO/SIGN -Application Expired
2009-03-17finaledP09CP01482Pima County permitC of O HistoricalC-OF-O/COTH -C of O
2001-05-10P01CP04673Pima County permitHistoricalSIGN/SIGN - — DP 2/18Application Expired
2000-06-05P00CP05801Pima County permitHistoricalPLUMB/COTH -Withdrawn
1999-06-09P99CP06234Pima County permitHistoricalMECH/COTH -Application Expired
1998-02-19P98CP01621Pima County permitHistoricalCOMBO/CALT -Application Expired
1998-02-05finaledP98CP01090Pima County permitHistoricalCOMBO/CTI -C of O
1997-12-17P97CP14746Pima County permitHistoricalPLUMB/COTH -Expired
1997-03-21finaledP97CP03077Pima County permitHistoricalCOMBO/CTI -C of O
1997-03-07C00118983Pima County permitHistoricalCOMBO/CALT -Expired
1997-03-07P97CP02369Pima County permitHistoricalCOMBO/CTI -Void
1996-11-07finaled118243Pima County permitHistoricalPMSHIST/ -Final
1995-04-2898204Pima County permitHistoricalPMSHIST/ -Expired
1987-07-10finaled9470Pima County permitHistoricalPMSHIST/ -Final

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Showing the 30 most recent county records — this parcel has more. The full set is on Pima County’s permit portal (search the parcel number).

Record numbers link to the issuing office’s official file — Pima County’s portal for county permits, the City of Tucson’s for city records. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 102120880 — 31 permits on file from 1987 to 2026 (12 historical, 6 building, 4 addition / alteration, 3 public records request) — assembled from the Pima County parcel file, the City of Tucson GIS layers, and Pima County’s Accela permit portal (searched by parcel and by address, because the county’s parcel links break on older records). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.