Electrical permit history — 639 W Ina Rd

639 W Ina Rd, Tucson — built 2005, with 31 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

639 W Ina Rd

Built 2005 — 2000s commercial stock · 31 permits on record; no permitted panel/service or HVAC work among them

Parcel
10204077A
Built
2005 (assessor record)
Jurisdiction
Unincorporated Pima County
Zoning
CB-1
Assessor use
Neighborhood Shopping Center
Parcel size
1.22 acres
Building area
8,454 sq ft (assessor record)
Sewer
Connection on file (2006, 2009, 2014) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)

See the property

County aerial photograph centered on 639 W Ina Rd, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 building permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 building permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. This parcel is in unincorporated Pima County, so we read the county’s own permit system — including its historical permits, which reach back into the 1990s where they exist. Every record links to the county’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

Recorded sales (2)

Recorded transfers from the Pima County Assessor — 2 of 2
DatePriceType
2024-08-14$51,000,000Warranty Deed
2015-02-23$46,000,000Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2025-09-15 (P25BP06955) — Sign — SHAKE SHACK WALL SIGNS.

Permit history (31)

Permit history for this parcel — 8 of 31 records
DateRecordWhatStatusValue
2025-09-15finaledP25BP06955Pima County permitOther StructuresSign — SHAKE SHACK WALL SIGNSFinal
2025-08-27P25BP06444Pima County permitBuildingCommercial Building OtherVoid
2025-07-03finaledP25BP05051Pima County permitBuildingTenant ImprovementC of O
2025-06-16P25BP04620Pima County permitDamage/DemoIssued
2025-06-13P25BP04573Pima County permitBuildingTenant ImprovementWithdrawn
2024-07-01finaledP24RR00137Pima County permitPublic Records RequestZVL 7001-7039 N Oracle/633-639 W InaComplete
2022-10-20finaledP22RR00172Pima County permitPublic Records RequestPRR2210-14Complete
2022-09-30finaledP22RR00151Pima County permitPublic Records RequestZVL Casa Adobes PlazaComplete
Show 23 older records
Permit history for this parcel — remaining 23 records
DateRecordWhatStatusValue
2020-12-10P20BP08675Pima County permitOther StructuresSignPermit Expired
2020-12-08finaledP20BP08618Pima County permitBuildingTenant ImprovementC of O
2015-12-22P15BP08260Pima County permitAddition / alterationCommercial Building AlterationApplication Expired
2015-11-17finaledP15BP07496Pima County permitElectrical / mechanicalElectrical EquipmentFinal
2015-08-24P15BP05756Pima County permitBuildingCommercial Building Other - COTHApplication Expired
2014-11-07finaledP14CP06950Pima County permitOther StructuresCOMBO/SIGN -Final
2013-06-27finaledP13CP04075Pima County permitOther StructuresCOMBO/SIGN - — DP 37/52Final
2013-04-30P13CP02541Pima County permitOther StructuresCOMBO/SIGN -Expired
2013-04-04P13CP01982Pima County permitOther StructuresCOMBO/SIGN - — DP 37/52Expired
2012-11-05P12HD00242Pima County permitCHFS – Health ReviewHEALTH/FFE - — 639 W INA RDIssued
2012-11-01finaledP12CP06442Pima County permitBuildingCOMBO/CTI -C of O
2012-09-21finaledP12CP05557Pima County permitBuildingCOMBO/CNEW -Final
2010-06-11finaledP10CP03597Pima County permitOther StructuresCOMBO/SIGN -Final
2010-06-08finaledP10CP03465Pima County permitOther StructuresCOMBO/SIGN -Final
2010-05-20P10CP03044Pima County permitOther StructuresCOMBO/SIGN - — 635 W INA RDApplication Expired
2009-10-06finaledP09CP05884Pima County permitBuildingCOMBO/COTH -Final
2009-09-28finaledP09CP05723Pima County permitOther StructuresCOMBO/SIGN -Final
2009-09-04finaledP09CP05243Pima County permitBuildingCOMBO/CTI - — CASAS ADOBE SHOPPING CENTER EXP.24033C of O
2009-09-04P09HD00171Pima County permitCHFS – Health ReviewHEALTH/FFE - — 635 W. INA ROADIssued
2006-10-11P06CP11786Pima County permitHistoricalSIGN/SIGN - — CASAS ADOBES PLAZA DP 28060Expired
2006-08-11finaledP06CP09668Pima County permitHistoricalCOMBO/CALT - — CASAS ADOBES PLAZA DP 28060C of O
2005-09-27P05CP11631Pima County permitHistoricalSIGN/SIGN - — CASAS ADOBES SHOPPING CNTR REV 1 (28/60)Application Expired
2005-08-02P05CP09110Pima County permitHistoricalMECH/CALT - — CASAS ADOBES PLAZAApplication Expired

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Showing the 31 most recent county records — this parcel has more. The full set is on Pima County’s permit portal (search the parcel number).

Record numbers link to the issuing office’s official file — Pima County’s portal for county permits, the City of Tucson’s for city records. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 10204077A — 31 permits on file from 2005 to 2025 (10 other structures, 9 building, 4 historical, 3 public records request) — assembled from the Pima County parcel file, the City of Tucson GIS layers, and Pima County’s Accela permit portal (searched by parcel and by address, because the county’s parcel links break on older records). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.