Electrical permit history — 215 W Giaconda Wy

215 W Giaconda Wy, Tucson — built 2000, with 23 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

215 W Giaconda Wy

Built 2000 — 2000s commercial stock · 23 permits on record; no permitted panel/service or HVAC work among them

Parcel
10203131C
Built
2000 (assessor record)
Jurisdiction
Unincorporated Pima County
Zoning
TR
Assessor use
Office Building 1 Story
Parcel size
1.54 acres
Building area
17,638 sq ft (assessor record)
Sewer
Connection on file (2000, 2001) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)

See the property

County aerial photograph centered on 215 W Giaconda Wy, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. This parcel is in unincorporated Pima County, so we read the county’s own permit system — including its historical permits, which reach back into the 1990s where they exist. Every record links to the county’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    Gear in this age range is usually still supported but is due for infrared scanning and torque verification if that has not been done recently. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    A pool or spa was permitted in 2001. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.

  • Routine

    Office and medical tenant improvements are usually limited by available panel spaces and branch circuit capacity, not by the service itself.

Recorded sales (2)

Recorded transfers from the Pima County Assessor — 2 of 2
DatePriceType
2007-05-02$2,895,000Warranty Deed
2003-09-10$3,050,000Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2023-10-05 (P23RW01502) — GIACONDA - Giaconda / Nanini.

Permit history (23)

Permit history for this parcel — 8 of 23 records
DateRecordWhatStatusValue
2023-10-05P23RW01502Pima County permitRight of WayGIACONDA - Giaconda / NaniniApproved
2021-06-04finaledP21RW01094Pima County permitRight of WayGIACONDA - Nanini Dr and Giaconda WayFinal
2017-03-20finaledP17RW00532Pima County permitRight of WayCOX COMMUNICATIONS - GIACONDA WAY - VERONICA LINGFELTERFinal
2014-12-03P14CP07477Pima County permitOther StructuresCOMBO/SIGN -Application Expired
2012-03-15finaledP12CP01552Pima County permitElectrical / mechanicalCOMBO/ELEC -Final
2010-07-28finaledP10CP04691Pima County permitC of O HistoricalCOMBO/COFO - — 215 W GIACONDA WYC of O
2006-09-14finaledP06CP10871Pima County permitHistoricalSIGN/SIGN - — D/P 20/52 215 W GIACONDA #121Final
2006-04-17finaledP06CP04687Pima County permitC of O HistoricalC-OF-O/COTH - — DP 20/52C of O
Show 15 older records
Permit history for this parcel — remaining 15 records
DateRecordWhatStatusValue
2005-01-24P05CP00850Pima County permitHistoricalSIGN/SIGN - — THE OFFICES AT GIACONDA WAY (D/P 20/52)Application Expired
2004-10-20finaledP04CP11758Pima County permitC of O HistoricalC-OF-O/COTH - — DP 20/52 SUITE 101C of O
2004-10-01P04CP11012Pima County permitHistoricalSIGN/SIGN - — (D/P 20/52)Application Expired
2004-06-08finaledP04CP06548Pima County permitHistoricalCOMBO/CTI - — DP 20/52 SUITE 135C of O
2001-07-31finaledP01CP07543Pima County permitHistoricalCOMBO/CTI - — CASAS ADOBES 3-B #131C of O
2001-06-28finaledP01CP06495Pima County permitHistoricalSIGN/SIGN - — OFFICES @ GIACONDA WY # 111Final
2001-02-13finaledP01CP01430Pima County permitHistoricalCOMBO/CTI -C of O
2001-01-30finaledP01CP00911Pima County permitHistoricalCOMBO/CTI - — OFFICES AT GIACONDA BLDG 2 SPACE 155C of O
2000-10-27finaledP00CP11054Pima County permitHistoricalCOMBO/CTI - — DP 20/52C of O
2000-10-16finaledP00CP10609Pima County permitHistoricalCOMBO/CTI -C of O
2000-10-16finaledP00CP10610Pima County permitHistoricalCOMBO/CTI -C of O
2000-10-02P00CP09927Pima County permitFence / wallWALL/FEN/WALL -Application Expired
2000-09-20finaledP00CP09603Pima County permitHistoricalCOMBO/CTI -C of O
2000-08-10finaledP00CP08072Pima County permitHistoricalCOMBO/CTI - — CASAS ADOBES ESTATESC of O
2000-02-08finaledP00CP01242Pima County permitHistoricalCOMBO/CNEW -C of O

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Record numbers link to the issuing office’s official file — Pima County’s portal for county permits, the City of Tucson’s for city records. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 10203131C — 23 permits on file from 2000 to 2023 (14 historical, 3 right of way, 3 c of o historical, 1 other structures) — assembled from the Pima County parcel file, the City of Tucson GIS layers, and Pima County’s Accela permit portal (searched by parcel and by address, because the county’s parcel links break on older records). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).