Electrical permit history — 1750 W Arroyo Vista Dr
1750 W Arroyo Vista Dr
- Electrical service: no service or panel permit on record. A 1988 house typically started with about 100 to 150 A service.
- Watch for: built 1988, when Federal Pacific and Zinsco panels were sold. Worth a look at the panel label.
- Other work on record: addition or alteration permit 2019 (expired without a final), plumbing work 2002.
From City of Tucson permits and the Pima County Assessor, checked 13 Nov 2026. Not an inspection.
The permanent link and the summary above, sent once. No list.One email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list.
Is it time to upgrade?
Possibly: no service upgrade is on record, and a 1988 house typically started with 100 to 150 A.
- Electrical service & panelWorth checkingNo service or panel permit on record. A 1988 house typically started with about 100 to 150 A service. Whether that still fits depends on what has been added since — air conditioning, a spa, an EV charger.
- Heating & coolingWorth checkingNo permit on record names this system. The assessor records cooling as Refrigeration and heating as Forced Air. Cooling equipment works harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes.
- Water heaterWorth checkingNo permit on record names this system. Water heaters are frequently swapped without a permit, so this line is especially weak evidence either way.
- RoofWorth checkingNo permit on record names this system. The assessor records the roof as Asphalt.
What that usually means electrically
- Era-based check — high priority
Federal Pacific Stab-Lok and Zinsco/Sylvania panels were still being installed into the 1980s. Both have documented failure-to-trip histories, by different routes: Stab-Lok breakers fail internally — the trip mechanism jams or sits out of calibration — while Zinsco breakers can weld to the bus, so the handle moves but the circuit stays live. Neither is fixed by a replacement breaker, which is why the panel is what gets replaced.
- Era-based check
100–150 A was typical. Workable for the original house, tight once you add EV charging or electric heat.
What to check at the panel
These are the things only someone standing at the panel can settle — about a minute’s work.
- The number stamped on the main breaker handle — 100, 125, 150, 175 or 200. That is the service rating, and no record on this page confirms it.
- The busbar rating printed on the panel label. It is a different number from the main breaker, and it is the one that decides how much solar a panel can take under the 120% rule.
- The manufacturer and catalog number on the label inside the door.
- How many full-size spaces are left, how many positions the label permits a tandem breaker in, and the tandem limit the label states. A full panel is a different job from a full service.
- The conductor material at the main lugs, and whether the terminations look clean and tight.
- Whether there is a separate meter-main outside as well as the panel indoors — that changes where a disconnect and any new feeder would land.
- Whether the water heater, dryer and range are gas or electric. No public record carries fuel type, and it is the single biggest variable in a load calculation — it can move the calculated load on the same house by more than 40 A.
- The brand on the door or the breaker faces. Federal Pacific panels usually read “Federal Pacific Electric” or “FPE”; Zinsco panels read “Zinsco”, or on later stock “Sylvania” or “Sylvania-Zinsco”. Finding a Square D, Eaton, Cutler-Hammer, Siemens or GE panel here is the ordinary result and is not a finding — those are current, supported lines with breakers on the shelf.
- Whether the kitchen counter, bathroom, garage and exterior receptacles have GFCI protection, and whether the test button actually trips them.
With those in hand you can run the numbers yourself. The load calculator does the NEC 220.82 optional-method calculation — the same method a permit application uses — and shows its work. It offers to start from the 1,600 sq ft on the assessor record; every other value is yours to enter. Open the load calculator
What these jobs cost here
Estimated ranges for this property, from its age, its size and the Tucson permit fee and code.
Electrical panel or service upgrade Estimate
$3,800
Most jobs like this land between $3,400 and $4,700.
The bottom of this range is a clean, simple job: single storey, framed wall, the panel staying where it is, a short service run, and nothing unexpected once the cover comes off. That job is real and we do book it — but it is the best case, not the average, and the figure above it is what most houses actually come to.
Priced from built 1988 (FPE/Zinsco panel era); City of Tucson permit fee and the 2023 NEC it has adopted.
Priced with Tucson Electric Power’s charges — TEP serves the City of Tucson. The assessor records framed walls, so no masonry drilling or stucco patch is priced.
What would move this price
- Only if the panel has to move — a clothes closet, a bathroom, over a stairway, or behind a door +$3,900
If every one of those turned out to apply, this becomes about $8,600. That is the worst realistic case.
- A service upgrade fixes capacity and the safety of the service equipment. It does not fix branch wiring. If the reason you are here is flickering lights, warm outlets or cloth-jacketed wiring, an upgrade is a down payment on a much bigger problem, and it is worth knowing that before you spend in the wrong order.
- You may not need the upgrade at all. NEC 220.87 lets an existing dwelling be sized from twelve months of actual metered demand rather than a calculated load, and real houses draw far less than the calculation predicts. Ask your utility for a year of interval data and have it run that way first. Two cautions so this does not backfire: the demand tile in a TEP online account shows on-peak demand only, which is not the annual maximum the code asks for — you want the formal usage-data release — and 220.87 proves CAPACITY and nothing else. It does not create empty breaker spaces, and it does not make an obsolete panel, or one whose breakers have a documented failure history, safe. Those are separate questions with separate answers — and where the era makes a brand worth checking, the report above says so on its own.
Air conditioning or heat pump replacement Estimate
$13,900
Most jobs like this land between $11,100 and $17,500.
Priced from 1,600 sq ft → about 3 tons, the size most Tucson quotes start from (about one ton per 500 sq ft); cooling on the assessor record reads “Refrigeration”; City of Tucson permit fee.
Priced for a one-story home. The assessor records an asphalt roof, so no foam re-coating is priced.
What would move this price
- Only if the duct has to be replaced — no record carries its condition, and on an attic system at this age it is a real possibility +$7,400
- Only if it is a foam or built-up roof that has to be re-coated at the patch +$900
If every one of those turned out to apply, this becomes about $25,700. That is the worst realistic case.
- Most Tucson houses carry a packaged unit on the roof, and how easy that roof is to reach is worth more than a thousand dollars of difference on the same equipment.
- If you are told a heat pump means you need a 200 A service, ask which load. It is almost never the compressor — a 5-ton outdoor unit is about a 31 A circuit. It is the electric BACKUP HEAT STRIP, which on a large kit can be a 109 A circuit on its own. In Tucson's mild heating season the strip kit can often be sized far smaller, or left out, and the service question disappears with it.
- Equipment here lasts ten to fourteen years, not the fifteen to twenty you will read nationally — a rooftop package unit at the short end. Replace rather than repair if the unit is twelve or more and the repair is over $1,500, if the compressor has failed and it is eight or more, or if the repair is over 40% of a new system.
- Most Tucson quotes size the unit at about one ton per 500 sq ft. A Manual J load calculation often comes out smaller, which means cheaper equipment and a unit that runs long enough to dry the air in the monsoon. Ask for the Manual J before you accept the tonnage.
- Whether the service is already 200 A. Nothing in the public record says so, and the number is stamped on the main breaker handle.
- Whether the panel can stay where it is. A panel in a closet, over stairs or behind a door has to move, and that alone adds $1,500 to $5,000.
- Whether the service comes in overhead or underground. This is priced as overhead; an underground service with an adequate lateral is a few hundred dollars cheaper, and one with an undersized lateral is thousands more.
- The duct. No record carries its condition, and on a Tucson house with duct in an unconditioned attic it is often worth more than a bigger machine.
- Whether that floor area is all conditioned space. An assessor figure can include a garage, an enclosed porch or an addition that was never cooled, and every square foot of that oversizes the equipment this page priced.
Price it for your house — change the assumptions (the panel’s location, the duct, the tonnage, whether the service is overhead or underground) and watch the number move.
Solar potential
The county’s building-footprint layer maps ≈ 2,516 sq ft of roof plan area here. In Tucson a rooftop array produces about 1,645 kWh per installed kW per year (PVWatts), so a typical 6–8 kW home system fits on a fraction of that roof and makes roughly 10,000–13,000 kWh a year. TEP credits exported surplus at its RCP rate — about 5¢/kWh for new applications, locked for 10 years — so sizing to the home’s own use matters more than filling the roof. Already have panels? Check whether they were permitted and finaled.
Flood and drainage
The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.
- FEMA: we did not read the federal flood map for this snapshot. Check FEMA’s flood map for this address ↗
- Local floodplain (the City of Tucson): local floodplain mapping is not reproduced here. A property can sit outside FEMA’s zone and still be inside a locally regulated floodplain, floodway, sheet-flooding area or erosion hazard setback, so check the authority’s own map before planning work. Pima County RFCD flood hazard map for parcel 137292520 ↗ · the City of Tucson ↗
The record behind this read
- Parcel
- 137292520
- Year constructed
- 1988 (county record)
- Permitting authority
- Tucson
- Zoning
- R-2
- Living area
- 1,600 sq ft
- Cooling
- Refrigeration
- Heating
- Forced Air
- Electrical service
- No service or panel permit on record. A 1988 house typically started with about 100 to 150 A service. (the era estimate is from the year built, 1988 — not a measurement)
Living area, cooling and heating come from the Pima County Assessor’s file published 28 Jan 2026. Check any row against Pima County’s own parcel record ↗.
What this means for work here
The most recent permit with evidence of issuance is dated 2019. The permit expired without a confirmed final status. The permit covers only the work described in that record.
What that reading rests on. The issuing offices hold 4 building permits for this parcel dated between 2002 and 2019. Two addition or alteration permits, one solar permit and one trade permit. 1 of them carries a final inspection; the other 3 were issued, expired or are still open, which is not the same as work completed.
Go straight to the records
Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.
City permit record (4): 2019 T19CM03053 · 2016 T16CM07668 · 2006 T06CM06238 · 2002 T02PL00624
Permit records courtesy of the City of Tucson — each link opens the City’s own file. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 137292520.
See an error? Report a correction · About this data.
Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.
In the public record: All homes in 85746 · Homes by ZIP code · Commercial property in 85746 · Permit data by neighborhood
Planning work at this home?
Arizona Electrical Solutions — electrical, HVAC, underground, design-build and general contracting in Tucson (four Arizona ROC licenses). The address, parcel and this report travel with your request.
Want a plain-English brief of this record first?
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
Permanent link: Electrical permit history for 1750 W Arroyo Vista Dr (aztucsonelectricalsolutions.com/property/137292520/1750-w-arroyo-vista-dr-tucson-az-85746)
Electrical summary — 1750 W Arroyo Vista Dr, Tucson, AZ 85746
Parcel 137292520Year built 1988Living area 1,600 sq ftPermit history City of TucsonRecord checked 13 Nov 2026
- Electrical service: no service or panel permit on record. A 1988 house typically started with about 100 to 150 A service.
- Watch for: built 1988, when Federal Pacific and Zinsco panels were sold. Worth a look at the panel label.
- Other work on record: addition or alteration permit 2019 (expired without a final), plumbing work 2002.
Permits on record, newest first
| Date | Permit | Type | Status |
|---|---|---|---|
| Jun 2019 | T19CM03053 | Addition or alteration permit | Expired (no final) |
| Mar 2002 | T02PL00624 | Plumbing | Final |
Voided or withdrawn permit records: 2 (not listed).
Era flags
- Built 1950–1990: Federal Pacific and Zinsco panels were sold in these years.
- Built before 1996: GFCI outlets were not required at all kitchen counters.
- Built before 2008: AFCI breakers were not required in most rooms.
Ask the home inspector to check
- The main breaker rating, and whether the panel is a Federal Pacific (Stab-Lok) or Zinsco — no service upgrade is on record.
- GFCI protection at kitchen, bath, garage and outdoor outlets.
Live report: https://www.aztucsonelectricalsolutions.com/property/137292520/1750-w-arroyo-vista-dr-tucson-az-85746
How this property compares nearby
Built in 1988 — earlier than about 49% of the 11,254 homes in ZIP 85746. 1,600 sq ft of living area — close to this ZIP’s median of 1,516 sq ft. About 35% of homes in this ZIP still cool with evaporative — this one has moved to refrigeration cooling. Properties on W ARROYO VISTA DR hold 32 City permits on record, 7 of them since 2022.
Counts and years from the same public records.
How this report was built
This is a reading of public records for parcel 137292520 — 4 City permits on file from 2002 to 2019 — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive. City of Tucson permit records go back to the mid-1990s, with fewer before 2006, when the City’s older paper files were only partly digitized. The construction year, living area, cooling, heating, roof and walls on this page come from our saved copy of the Assessor’s own published data file (dated 28 Jan 2026). The sewer connection file and the flood map were not read for this snapshot. A permit that is absent here may predate the digitized record or sit in a system this snapshot did not read. This record was built 22 Aug 2026 and compared against the City’s 13 Nov 2026 permit export, with no change for this parcel.
What this report is and is not. This is a screening report written by Arizona Electrical Solutions from public records — the year the building went up, how it is classified and what has been permitted. It is not an inspection, an appraisal, a floodplain determination, or engineering, legal or purchasing advice, and nothing in it confirms what is installed at this address: a permit shows what was permitted, a missing permit does not mean nothing was done, and era notes describe what was common when the building went up, not what is in this one. Price figures are estimates, not quotes. The issuing agency’s own record is the official one and controls over anything summarized here — every permit links to it. Only someone looking at the panel can confirm the service size, the panel brand or the wiring.
Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.
Permit history: City of Tucson addresses, back to the mid-1990s. Elsewhere in Pima County: property facts from the Assessor, no permit history yet.