Electrical permit history — 9255 E Palm Tree Dr

9255 E Palm Tree Dr, Tucson — built 1970, with 8 permits on record. Review electrical, HVAC and remodel history with links to official records.

Home

9255 E Palm Tree Dr

Built 1970 — aluminum branch-wiring era · last permitted panel/service work 2012 (finaled)

Parcel
136072270
Built
1970 (county record)
Jurisdiction
Tucson
Zoning
R-1
Assessor use
Sfr Grade 010-3 Urban Subdivided
Parcel size
0.21 acres
Sewer
Connection on file (1970) (county sewer connection records)
Historic preservation
Not on file (City of Tucson HP layers)
Typical original service for a 1970 home
approximately 100 A
Service on record
City records show the 2012 permit was finalized; the permit description states “UPGRADE:ELECTRIC 200AMP:RES” — an increase in capacity as described, not a confirmed installed rating.

See the property

County aerial photograph centered on 9255 E Palm Tree Dr, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Flood and drainage — two different maps

The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map. Pima County’s Regional Flood Control District and the City of Tucson regulate against their own, and that is the one a permit here is judged against.

FEMA flood hazard (federal)
FEMA flood hazard (federal) for 9255 E Palm Tree Dr, Tucson area, Arizona

FEMA National Flood Hazard Layer — zones and base-flood-elevation contours. Federal insurance mapping. Open this property on FEMA’s official flood map ↗

Local regulatory floodplain (county and City)
Local regulatory floodplain (county and City) for 9255 E Palm Tree Dr, Tucson area, Arizona

Pima County RFCD local floodplains, floodways, sheet-flooding and erosion hazard areas, with the City of Tucson’s own mapped flood hazards. This is the map local floodplain regulation uses.

Parcel outlined in yellow. Both maps are drawn live from the agencies’ own map services at the same extent, so you can compare them directly. They are context for planning, not a floodplain determination — for that, ask the floodplain administrator for the jurisdiction shown below.

  • FEMA: the federal flood layer did not answer when this page was built. That is a lookup failure, not a statement about the property.
  • Pima County RFCD: No Pima County regulated local floodplain, floodway, sheet-flooding area or erosion hazard area is mapped at this location. That is the county's map, not a statement about drainage on the site.

Is it time to upgrade?

  • Electrical service & panelCurrentLast permitted 2012 (14 years ago). City inspection record: ELECTRIC - FINAL approved 2012-01-23. Contractor of record: SUNSTATE POWER AND SOLAR SOLUTIONS L L C. The permit describes an increase in capacity, which is the single best sign the electrical has actually been brought forward. T12EL00104 — UPGRADE:ELECTRIC 200AMP:RES
  • Heating & coolingNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2014 solar pv permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Cooling equipment works harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes.
  • Water heaterNot in this windowNothing in the permit records we read for this parcel that names this system. Water heaters are frequently swapped without a permit, so this line is especially weak evidence either way.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system.
  • Plumbing work on recordNot in this windowNothing in the permit records we read for this parcel that names this system. Unremarkable — plenty of buildings never need a permitted plumbing repair.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    This is the aluminum branch-circuit window (roughly 1965–1973). Solid aluminum on 15/20 A circuits is a recognized fire hazard at the terminations and needs approved repair — COPALUM or AlumiConn, not a wire nut. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check — high priority

    Federal Pacific (Stab-Lok) and Zinsco/Sylvania panels were sold through this period. Stab-Lok breakers have a documented history of failing to trip internally; Zinsco breakers can weld to the bus so the handle moves without breaking the circuit. In both cases a replacement breaker does not resolve it — the panel itself is what gets replaced. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    100 A was typical. Adding an EV charger, heat pump, or casita usually forces a service upgrade first. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    Solar was permitted here in 2014. That means there is an existing interconnection, and the main breaker and busbar rating already carry a PV backfeed — so anything else you add (an EV charger, a heat pump) has to be checked against what is left under the 120% rule, not against the service size alone.

Most recent permit on record for this parcel: 2014-12-09 (T14CM08408) — INSTALL 2.25 kw PV SOLAR ROOFMOUNT WITH MATERIALS.

Permit history (8)

Permit history for this parcel — 8 of 8 records
DateRecordWhatStatusValue
2014-12-09finaledT14CM08408City permit recordSolar PVINSTALL 2.25 kw PV SOLAR ROOFMOUNT WITH MATERIALSFinal
2014-11-13T14CM07764City permit recordCOMBOADD BATHROOM TO RESWithdrwn
2012-12-05finaledT12CM07704City permit recordCOMBOREPLACE GAS LINE OVER ROOFFinal
2012-12-05T12OT01636City permit recordC-OF-OREPLACE GAS LINE OVER ROOFWithdrwn
2012-10-19finaledT12CM06676City permit recordSolar PVADD; SOLAR WATER HEATERFinal
2012-07-27finaledT12CM04596City permit recordCOMBOADD; PHOTOVOTAIC SYSTEM TO RESFinal
2012-01-12finaledT12EL00104City permit recordELECTUPGRADE:ELECTRIC 200AMP:RESFinal
1998-12-10finaledT98BU03013City permit recordFence / wallWALL:PATIO 183 LF OF 6 TD 12-00-27Final

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.

In the public record: All homes in 85710 · Homes by ZIP code · Commercial property in 85710 · Permit data by neighborhood

Planning work at this home?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 136072270 — 8 permits on file from 1998 to 2014 (3 combo, 2 solar pv, 1 c-of-o, 1 elect) — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-18; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.