Electrical permit history — 2509 S Calle Cordova
2509 S Calle Cordova
- Electrical service: no service or panel permit on record. A 1967 house likely still has its original 100 A service.
- Watch for: built 1967, the years some homes got aluminum branch wiring. Worth a look at the outlets and panel.
- Other work on record: heat pump permitted 2026 (permit not closed), trade permit 2017.
From City of Tucson permits and the Pima County Assessor, checked 13 Nov 2026. Not an inspection.
The permanent link and the summary above, sent once. No list.One email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list.
Is it time to upgrade?
Likely yes: no service upgrade is on record for this 1967 house.
- Electrical service & panelLikely needs attentionNo service or panel permit on record. A 1967 house likely still has its original 100 A service. The panel makes and wiring methods of that era are what the era notes below flag, and only a look at the panel settles it.
- Heating & coolingWorth checkingA 2026 permit covers this work, but the record shows no final inspection (official status: Issued). The assessor records cooling as Refrigeration and heating as Forced Air (assessor characteristics can lag permitted work). TC-RES-0626-03496 — Installation of new 1 ton mini split heat pump, condenser on roof.
- Water heaterWorth checkingNo permit on record names this system. Water heaters are frequently swapped without a permit, so this line is especially weak evidence either way.
- RoofWorth checkingNo permit on record names this system. The assessor records the roof as Built Up.
What that usually means electrically
- Era-based check — high priority
This is the aluminum branch-circuit window (roughly 1965–1973). Solid aluminum on 15/20 A circuits is a recognized fire hazard at the terminations and needs approved repair — COPALUM or AlumiConn, not a wire nut.
- Era-based check — high priority
Federal Pacific (Stab-Lok) and Zinsco/Sylvania panels were sold through this period. Stab-Lok breakers have a documented history of failing to trip internally; Zinsco breakers can weld to the bus so the handle moves without breaking the circuit. In both cases a replacement breaker does not resolve it — the panel itself is what gets replaced.
- Era-based check
100 A was typical for the era. Adding an EV charger, heat pump or casita requires a load calculation; an upgrade or a load-management device may be needed.
- Routine
A trade permit was pulled in 2017. Trade permits cover electrical, plumbing, and mechanical work individually, so some permitted trade work has been done here since.
What to check at the panel
These are the things only someone standing at the panel can settle — about a minute’s work.
- The number stamped on the main breaker handle — 100, 125, 150, 175 or 200. That is the service rating, and no record on this page confirms it.
- The busbar rating printed on the panel label. It is a different number from the main breaker, and it is the one that decides how much solar a panel can take under the 120% rule.
- The manufacturer and catalog number on the label inside the door.
- How many full-size spaces are left, how many positions the label permits a tandem breaker in, and the tandem limit the label states. A full panel is a different job from a full service.
- The conductor material at the main lugs, and whether the terminations look clean and tight.
- Whether there is a separate meter-main outside as well as the panel indoors — that changes where a disconnect and any new feeder would land.
- Whether the water heater, dryer and range are gas or electric. No public record carries fuel type, and it is the single biggest variable in a load calculation — it can move the calculated load on the same house by more than 40 A.
- The brand on the door or the breaker faces. Federal Pacific panels usually read “Federal Pacific Electric” or “FPE”; Zinsco panels read “Zinsco”, or on later stock “Sylvania” or “Sylvania-Zinsco”. Finding a Square D, Eaton, Cutler-Hammer, Siemens or GE panel here is the ordinary result and is not a finding — those are current, supported lines with breakers on the shelf.
- The conductors landing on the 15 and 20 A breakers. Silver-coloured rather than copper is the 1965–1973 solid-aluminum branch-circuit question, and it is repaired at the terminations, not by replacing the panel. The aluminum feeder between meter and panel, and the aluminum service conductors overhead, are normal on houses of every era and are a different thing entirely.
- Whether the kitchen counter, bathroom, garage and exterior receptacles have GFCI protection, and whether the test button actually trips them.
With those in hand you can run the numbers yourself. The load calculator does the NEC 220.82 optional-method calculation — the same method a permit application uses — and shows its work. It offers to start from the 1,837 sq ft on the assessor record; every other value is yours to enter. Open the load calculator
What these jobs cost here
Estimated ranges for this property, from its age, its size and the Tucson permit fee and code.
Electrical panel or service upgrade Estimate
$5,200
Most jobs like this land between $4,500 and $6,300.
The bottom of this range is a clean, simple job: single storey, framed wall, the panel staying where it is, a short service run, and nothing unexpected once the cover comes off. That job is real and we do book it — but it is the best case, not the average, and the figure above it is what most houses actually come to.
Priced from built 1967 (possible aluminum-wiring era — based on year only, not observed); City of Tucson permit fee and the 2023 NEC it has adopted.
Priced with Tucson Electric Power’s charges — TEP serves the City of Tucson. The assessor records block, brick or adobe walls, so the core drilling and patch are priced in.
What would move this price
- Only if the panel has to move — a clothes closet, a bathroom, over a stairway, or behind a door +$3,900
- Only if the mast is undersized or corroded — common at this age +$1,300
- Only if the metal water and gas piping are not already bonded — usually not, at this age +$600
If every one of those turned out to apply, this becomes about $12,000. That is the worst realistic case.
- A service upgrade fixes capacity and the safety of the service equipment. It does not fix branch wiring. If the reason you are here is flickering lights, warm outlets or cloth-jacketed wiring, an upgrade is a down payment on a much bigger problem, and it is worth knowing that before you spend in the wrong order.
- You may not need the upgrade at all. NEC 220.87 lets an existing dwelling be sized from twelve months of actual metered demand rather than a calculated load, and real houses draw far less than the calculation predicts. Ask your utility for a year of interval data and have it run that way first. Two cautions so this does not backfire: the demand tile in a TEP online account shows on-peak demand only, which is not the annual maximum the code asks for — you want the formal usage-data release — and 220.87 proves CAPACITY and nothing else. It does not create empty breaker spaces, and it does not make an obsolete panel, or one whose breakers have a documented failure history, safe. Those are separate questions with separate answers — and where the era makes a brand worth checking, the report above says so on its own.
- Solid aluminum branch circuits do not mean a rewire. Approved pigtailing — AlumiConn or COPALUM — runs $8 to $20 a device, so $1,200 to $3,000 for a typical house, and it usually satisfies the insurer. A whole-house rewire is $9,000 to $24,000 on a 1,500 sq ft house. Get the pigtail quote first.
Air conditioning or heat pump replacement Estimate
$8,500
Most jobs like this land between $6,700 and $11,600.
Priced from a 1-ton ductless system on the 2026 permit TC-RES-0626-03496 (issued — completion not confirmed), so the replacement is priced like for like; cooling on the assessor record reads “Refrigeration”; City of Tucson permit fee.
What would move this price
- Only if the duct has to be replaced — no record carries its condition, and on an attic system at this age it is a real possibility +$8,500
If every one of those turned out to apply, this becomes about $20,100. That is the worst realistic case.
- Because a permit names the size, this is priced at that size rather than from floor area. Worth asking whether that size was ever right: a Manual J often comes out smaller, and a correctly sized machine costs less and behaves better in the monsoon.
- Ductless is worth pricing against a ducted job any time new duct would otherwise be needed — a swamp-cooler house, an addition, a casita or a converted garage. Three or four heads often beat a ducted conversion outright.
- If you are told a heat pump means you need a 200 A service, ask which load. It is almost never the compressor — a 5-ton outdoor unit is about a 31 A circuit. It is the electric BACKUP HEAT STRIP, which on a large kit can be a 109 A circuit on its own. In Tucson's mild heating season the strip kit can often be sized far smaller, or left out, and the service question disappears with it.
- Equipment here lasts ten to fourteen years, not the fifteen to twenty you will read nationally — a rooftop package unit at the short end. Replace rather than repair if the unit is twelve or more and the repair is over $1,500, if the compressor has failed and it is eight or more, or if the repair is over 40% of a new system.
- Whether the service is already 200 A. Nothing in the public record says so, and the number is stamped on the main breaker handle.
- Whether the panel can stay where it is. A panel in a closet, over stairs or behind a door has to move, and that alone adds $1,500 to $5,000.
- Whether the service comes in overhead or underground. This is priced as overhead; an underground service with an adequate lateral is a few hundred dollars cheaper, and one with an undersized lateral is thousands more.
- The duct. No record carries its condition, and on a Tucson house with duct in an unconditioned attic it is often worth more than a bigger machine.
- Whether that floor area is all conditioned space. An assessor figure can include a garage, an enclosed porch or an addition that was never cooled, and every square foot of that oversizes the equipment this page priced.
Price it for your house — change the assumptions (the panel’s location, the duct, the tonnage, whether the service is overhead or underground) and watch the number move.
Solar potential
The county’s building-footprint layer maps ≈ 3,299 sq ft of roof plan area here. In Tucson a rooftop array produces about 1,645 kWh per installed kW per year (PVWatts), so a typical 6–8 kW home system fits on a fraction of that roof and makes roughly 10,000–13,000 kWh a year. TEP credits exported surplus at its RCP rate — about 5¢/kWh for new applications, locked for 10 years — so sizing to the home’s own use matters more than filling the roof. Already have panels? Check whether they were permitted and finaled.
Flood and drainage
The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.
- FEMA: we did not read the federal flood map for this snapshot. Check FEMA’s flood map for this address ↗
- Local floodplain (the City of Tucson): local floodplain mapping is not reproduced here. A property can sit outside FEMA’s zone and still be inside a locally regulated floodplain, floodway, sheet-flooding area or erosion hazard setback, so check the authority’s own map before planning work. Pima County RFCD flood hazard map for parcel 135103880 ↗ · the City of Tucson ↗
The record behind this read
- Parcel
- 135103880
- Year constructed
- 1967 (county record)
- Permitting authority
- Tucson
- Zoning
- R-1
- Living area
- 1,837 sq ft
- Cooling
- Refrigeration
- Heating
- Forced Air
- Electrical service
- No service or panel permit on record. A 1967 house likely still has its original 100 A service. (the era estimate is from the year built, 1967 — not a measurement)
Living area, cooling and heating come from the Pima County Assessor’s file published 28 Jan 2026. Check any row against Pima County’s own parcel record ↗.
What this means for work here
The most recent permit with evidence of issuance is dated 2026. The work was permitted, but final completion is not confirmed. The permit covers only the work described in that record.
What that reading rests on. The issuing offices hold 2 building permits for this parcel dated between 2017 and 2026. Two trade permits. 1 of them carries a final inspection; the other one was issued, expired or is still open, which is not the same as work completed. There are 3 code-enforcement cases recorded against the parcel, all of them closed. We do not reproduce complaint text — it routinely names people with no connection to the property.
Go straight to the records
Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.
Residential building (1): 2026 TC-RES-0626-03496
City permit record (1): 2017 T17CM08523
Code enforcement cases (3): 2015 T15DV07023 · 2012 T12DV07327 · 2010 T10DV08635
Permit records courtesy of the City of Tucson — each link opens the City’s own file. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 135103880.
See an error? Report a correction · About this data.
Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.
In the public record: All homes in 85710 · Homes by ZIP code · Commercial property in 85710 · Permit data by neighborhood
Planning work at this home?
Arizona Electrical Solutions — electrical, HVAC, underground, design-build and general contracting in Tucson (four Arizona ROC licenses). The address, parcel and this report travel with your request.
Want a plain-English brief of this record first?
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
Permanent link: Electrical permit history for 2509 S Calle Cordova (aztucsonelectricalsolutions.com/property/135103880/2509-s-calle-cordova-tucson-az-85710)
Electrical summary — 2509 S Calle Cordova, Tucson, AZ 85710
Parcel 135103880Year built 1967Living area 1,837 sq ftPermit history City of TucsonRecord checked 13 Nov 2026
- Electrical service: no service or panel permit on record. A 1967 house likely still has its original 100 A service.
- Watch for: built 1967, the years some homes got aluminum branch wiring. Worth a look at the outlets and panel.
- Other work on record: heat pump permitted 2026 (permit not closed), trade permit 2017.
Permits on record, newest first
| Date | Permit | Type | Status |
|---|---|---|---|
| Jun 2026 | TC-RES-0626-03496 | Heating & cooling | Open |
| Nov 2017 | T17CM08523 | Trade permit | Final |
Era flags
- Built 1965–1973: the years some homes got solid aluminum branch wiring.
- Built 1950–1990: Federal Pacific and Zinsco panels were sold in these years.
- Built before 1996: GFCI outlets were not required at all kitchen counters.
- Built before 2008: AFCI breakers were not required in most rooms.
Ask the home inspector to check
- Whether the 2026 heating and cooling permit was finished — the City shows no final inspection.
- The 15 and 20 A circuits for solid aluminum wiring (silver-colored wire at outlets and breakers).
- The main breaker rating, and whether the panel is a Federal Pacific (Stab-Lok) or Zinsco — no service upgrade is on record.
Live report: https://www.aztucsonelectricalsolutions.com/property/135103880/2509-s-calle-cordova-tucson-az-85710
How this property compares nearby
Built in 1967 — earlier than about 49% of the 15,466 homes in ZIP 85710. 1,837 sq ft of living area — above this ZIP’s median of 1,592 sq ft. About 33% of homes in this ZIP still cool with evaporative — this one has moved to refrigeration cooling. Properties on S CALLE CORDOVA hold 92 City permits on record, 22 of them since 2022.
Counts and years from the same public records.
How this report was built
This is a reading of public records for parcel 135103880 — 2 City permits on file from 2017 to 2026 and 3 code enforcement cases — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive. City of Tucson permit records go back to the mid-1990s, with fewer before 2006, when the City’s older paper files were only partly digitized. The construction year, living area, cooling, heating, roof and walls on this page come from our saved copy of the Assessor’s own published data file (dated 28 Jan 2026). The sewer connection file and the flood map were not read for this snapshot. A permit that is absent here may predate the digitized record or sit in a system this snapshot did not read. This record was built 13 Nov 2026 from the City’s permit export of that day.
What this report is and is not. This is a screening report written by Arizona Electrical Solutions from public records — the year the building went up, how it is classified and what has been permitted. It is not an inspection, an appraisal, a floodplain determination, or engineering, legal or purchasing advice, and nothing in it confirms what is installed at this address: a permit shows what was permitted, a missing permit does not mean nothing was done, and era notes describe what was common when the building went up, not what is in this one. Price figures are estimates, not quotes. The issuing agency’s own record is the official one and controls over anything summarized here — every permit links to it. Only someone looking at the panel can confirm the service size, the panel brand or the wiring.
Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.
Permit history: City of Tucson addresses, back to the mid-1990s. Elsewhere in Pima County: property facts from the Assessor, no permit history yet.