Electrical permit history — 1378 S Avenida Polar

1378 S Avenida Polar, Tucson — built 1964, with 73 permits on record. Review electrical, HVAC and remodel history with links to official records.

Electrical Property Screening Report · Home

1378 S Avenida Polar

A screening report for electrical planning, assembled from public-record indicators. It is not an official record and every figure in it should be verified against the issuing agency before it is relied on.

Verify parcel data at official source ↗

Built 1964 — post-war 60–100 A service era · last permitted panel/service work 2015 (finaled); a newer 2020 permit is expired without a final · HVAC 2022 (finaled); a newer 2024 permit is expired without a final · 2 open code cases

Is it time to upgrade?

  • Electrical service & panelFinaled permit foundA newer 2020 permit for the same system is recorded as “Expired” — The permit expired without a confirmed final status. The permit description states “ADD NEW WATER AND ELECTRCAL FOR LAUNDRY AND ELECTRIC PANEL UPGRADE TO 200A TO CONVERT FROM COOLER TO”. Last permitted 2015 (11 years ago). Worth reading the permit itself: it names the service but does not read as an increase in capacity, so this may have been a like-for-like replacement rather than an upgrade. T15CM03948 — REPLACE 100 AMP MAIN BREAKER - TEP METER CHANGEOUT PROGRAM (APA)
  • Heating & coolingFinaled permit foundA newer 2024 permit for the same system is recorded as “Expired” — The permit expired without a confirmed final status. The permit description states “HVAC changeout. Like for like. (1) 3 ton condenser to be placed on roof. (1) 80k btu furnace to be placed in attic.”. Last permitted 2022 (4 years ago). Cooling equipment works harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. T22CM03269 — install new 2 ton split system
  • Water heaterLikely dueLast permitted 2010 (16 years ago). T10PL00976 — REPLACE: WATER HEATER (APA)
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. The assessor records the roof as Composition Shingle.
  • Plumbing work on recordNot in this windowNothing in the permit records we read for this parcel that names this system. Unremarkable — plenty of buildings never need a permitted plumbing repair.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitized. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    A finaled 2015 panel/service permit is on record for this parcel, which makes it unlikely the original 60–100 A equipment is still in place. That is a permit record, not an inspection — verify the installed rating and the panel brand on site before sizing anything new. The permit record does not confirm this; an on-site inspection is required.

  • Worth looking at

    There are 2 open code enforcement cases on this parcel. An open case can hold up a permit, and if it touches unpermitted work the electrical scope usually has to be brought up to code as part of resolving it.

  • Era-based check

    Grounded branch circuits did not become the norm until the early 1960s — much of the original wiring here is likely ungrounded. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    Cloth-jacketed NM cable is common in this era. The jacket embrittles with age and heat, particularly in Tucson attics. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    There is an electrical reconnect permit from 2020. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.

  • Worth confirming

    A pool or spa was permitted in 2010. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.

  • Routine

    A trade permit was pulled in 2022. Trade permits cover electrical, plumbing, and mechanical work individually, so some permitted trade work has been done here since.

What to check at the panel

Everything above is read off public records. These are the things only someone standing at the panel can settle, and they take about a minute. Check them against the rating the permit above describes rather than against the era — the permit is the better evidence, and neither one is an inspection.

  1. The number stamped on the main breaker handle — 100, 125, 150, 175 or 200. That is the service rating, and no record on this page confirms it.
  2. The busbar rating printed on the panel label. It is a different number from the main breaker, and it is the one that decides how much solar a panel can take under the 120% rule.
  3. The manufacturer and catalog number on the label inside the door.
  4. How many full-size spaces are left, how many positions the label permits a tandem breaker in, and the tandem limit the label states. A full panel is a different job from a full service.
  5. The conductor material at the main lugs, and whether the terminations look clean and tight.
  6. Whether there is a separate meter-main outside as well as the panel indoors — that changes where a disconnect and any new feeder would land.
  7. Whether the water heater, dryer and range are gas or electric. No public record carries fuel type, and it is the single biggest variable in a load calculation — it can move the calculated load on the same house by more than 40 A.
  8. The brand on the door or the breaker faces. Federal Pacific panels usually read “Federal Pacific Electric” or “FPE”; Zinsco panels read “Zinsco”, or on later stock “Sylvania” or “Sylvania-Zinsco”. Finding a Square D, Eaton, Cutler-Hammer, Siemens or GE panel here is the ordinary result and is not a finding — those are current, supported lines with breakers on the shelf.
  9. Whether the kitchen counter, bathroom, garage and exterior receptacles have GFCI protection, and whether the test button actually trips them.

With those in hand you can run the numbers yourself. The load calculator does the NEC 220.82 optional-method calculation — the same method a permit application uses — and shows its work.

Open the load calculator →

What these jobs cost here

The cooling equipment here was permitted in 2022 — replacement is not due yet.

Electrical panel or service upgrade

$3,800

Most jobs like this land between $3,400 and $4,700.

The bottom of this range is a clean, simple job: single storey, framed wall, the panel staying where it is, a short service run, and nothing unexpected once the cover comes off. That job is real and we do book it — but it is the best case, not the average, and the figure above it is what most houses actually come to.

Priced from built 1964 (post-war 60–100 A service era), City of Tucson permit fee and the 2023 NEC it has adopted, Tucson Electric Power as the serving utility, framed walls on the assessor record, so no masonry drilling or stucco patch is priced and a finalled permit recording a 100 A service, which is below 200 A — the upgrade is genuinely still open here.

What would move this price
  • Only if the panel has to move — a clothes closet, a bathroom, over a stairway, or behind a door +$3,900
  • Only if the mast is undersized or corroded — common at this age +$1,300
  • Only if the metal water and gas piping are not already bonded — usually not, at this age +$600
  • Only if the original fuse or split-bus panel is still in service +$1,700

If every one of those turned out to apply, this becomes about $12,100. That is the worst realistic case, not a prediction — none of them is a claim about your house.

Before you spend anything
  • A service upgrade fixes capacity and the safety of the service equipment. It does not fix branch wiring. If the reason you are here is flickering lights, warm outlets or cloth-jacketed wiring, an upgrade is a down payment on a much bigger problem, and it is worth knowing that before you spend in the wrong order. (The report reserves the era-specific wiring checks for the years they actually apply to — read those above.)
  • You may not need the upgrade at all. NEC 220.87 lets an existing dwelling be sized from twelve months of actual metered demand rather than a calculated load, and real houses draw far less than the calculation predicts. Ask your utility for a year of interval data and have it run that way first. Two cautions so this does not backfire: the demand tile in a TEP online account shows on-peak demand only, which is not the annual maximum the code asks for — you want the formal usage-data release — and 220.87 proves CAPACITY and nothing else. It does not create empty breaker spaces, and it does not make an obsolete panel, or one whose breakers have a documented failure history, safe. Those are separate questions with separate answers — and where the era makes a brand worth checking, the report above says so on its own.

A finalled HVAC permit from 2022 is on record, so the equipment is inside its expected life and we are not pricing a replacement.

What the record cannot tell us
  • Whether the service is already 200 A. Nothing in the public record says so, and the number is stamped on the main breaker handle.
  • Whether the panel can stay where it is. A panel in a closet, over stairs or behind a door has to move, and that alone adds $1,500 to $5,000.
  • Whether the service comes in overhead or underground. This is priced as overhead; an underground service with an adequate lateral is a few hundred dollars cheaper, and one with an undersized lateral is thousands more.

This is an estimate, not a quote. It is built from this property’s public record and current City of Tucson market rates — nobody has seen your panel, your duct or your roof. A real price comes from a site visit, and the things that move it most are the ones listed above that no record carries.

Price it for your house →

Change the assumptions — the panel’s location, the duct, the tonnage, whether the service is overhead or underground — and watch the number move. That is the point of it.

Solar potential

The county’s building-footprint layer maps ≈ 134,228 sq ft of roof plan area here across 13 structures. In Tucson a rooftop array produces about 1,645 kWh per installed kW per year (PVWatts), so a typical 6–8 kW home system fits on a fraction of that roof and makes roughly 10,000–13,000 kWh a year. TEP credits exported surplus at its RCP rate — about 5¢/kWh for new applications, locked for 10 years — so sizing to the home’s own use matters more than filling the roof. If solar shows in this property’s permit record, check whether it was permitted and finaled.

Flood and drainage

The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.

The record behind this read

Parcel
135020080
Year constructed
1964 (county record)
Permitting authority
Tucson
Zoning
C-2
Living area
186,864 sq ft
Heating
Forced Air
Estimated electrical service era
approximately 60–100 A (estimated from the year built, 1964 — not a measurement; verify on site)
Service on record
City records show the 2015 permit was finalized; the permit description states “REPLACE 100 AMP MAIN BREAKER - TEP METER CHANGEOUT PROGRAM (APA)”.

The living area and heating above come from the Pima County Assessor’s record, as we read it on 28 Jan 2026. Each other row names its own source.

The most recent permitted work on this parcel was in 2026. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What this means for work here

Informational public-record summary — not engineering, inspection, valuation or purchasing advice, and not the official record.

The most recent permitted work on this parcel was in 2026. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What that reading rests on. The issuing offices hold 73 building permits for this parcel dated between 1998 and 2026. By category the work is trade permit (66), addition / alteration (4), electrical reconnect and private improvement agreement. 51 of them carry a final inspection; the other 22 were issued, expired or are still open, which is not the same as work completed. There are 23 code-enforcement cases recorded against the parcel, 2 of which are open. We do not reproduce complaint text — it routinely names people with no connection to the property.

Go straight to the records

Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.

Read the records yourself. We republish selected facts and record numbers so you can find the file; the issuing agency’s record controls. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 135020080. Permit and parcel information courtesy of the City of Tucson and Pima County; their files are the official record and control over anything summarized here.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.

In the public record: All homes in 85710 · Homes by ZIP code · Commercial property in 85710 · Permit data by neighborhood

Planning work at this home?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

What the flood note is not. The FEMA map linked above is the National Flood Hazard Layer — the federal insurance map. Local floodplain mapping is not reproduced here; use the authority’s own map, linked above. Nothing here is a floodplain determination, an elevation certificate, or a substitute for one. A parcel can straddle a boundary, and a Letter of Map Amendment can remove a structure the map still covers. For a determination, ask the floodplain administrator for the jurisdiction named above; for a design that has to satisfy one, that is work we do.

How this property compares nearby

Built in 1964 — earlier than about 56% of the 15,466 homes in ZIP 85710. 186,864 sq ft of living area — above this ZIP’s median of 1,592 sq ft. Properties on S AVENIDA POLAR hold 86 City permits on record, 15 of them since 2022.

Computed from the same public records as this report — counts and years, not an appraisal.

Complete permit record (96 entries)

Every permit and case we hold for this parcel, newest first. Each number links to the official file.

YearNumberTypeStatus
2026TC-RES-0426-02208Residential Addition/Alteration PermitInspections
2026SP-NRP-0426-00070Electrical ReconnectInspections
2026TC-RES-0326-01217Residential Addition/Alteration PermitInspections Complete
2026CE-VIO0126-00395Work without permitActive
2025CE-VIO1125-05014FireClosed - Resolved
2025CE-VIO1125-05013FireActive
2024CE-VIO1024-04321Code enforcement caseClosed - Unfounded
2024TC-COM-0524-00892Commercial Trade PermitExpired
2024CE-VIO0424-01398Work without permitClosed - Unfounded
2022T22CM07032Commercial Trade PermitComplete
2022T22CM03269Commercial Trade PermitComplete
2022T22CM01248Commercial Trade PermitComplete
2021T21CM03912Commercial Trade PermitExpired
2021T21CM02504Residential Trade PermitComplete
2020T20CM06976Residential Trade PermitComplete
2020T20DV06681PEDDLERSNOVERIFY
2020T20CM06237Residential Trade PermitComplete
2020T20DV05273WORK WITHOUT PERMITS-RESIDENTLNOVERIFY
2020T20DV04855RESIDENTIAL ZONINGNOVERIFY
2020T20DV02209RESIDENTIAL ZONINGNOVERIFY
2020T20CM01288Residential Trade PermitExpired
2019T19CM01777Residential Trade PermitComplete
2019T19DV00651MULTI-AGENCY INSPECTION TEAMNOVERIFY
2018T18DV06702FIRE AT COMMERCIAL BUILDINGNOVERIFY
2018T18DV03668MULTIPLE TYPESNOVERIFY
2018T18CM04012Commercial Trade PermitComplete
2018T18DV01083EXCESSIVE INTERIOR STORAGENOVERIFY
2018T18CM01554Commercial Trade PermitComplete
2017T17DV05051RESIDENTIAL FIRECOMPLIAN
2017T17CM06464Commercial Trade PermitComplete
2017T17CM05210Commercial Trade PermitComplete
2017T17CM05209Commercial Trade PermitComplete
2017T17PI00023Private Improvement AgreementApproved
2017T17CM01274Residential Trade PermitComplete
2016T16CM04548Commercial Addition/Alteration PermitComplete
2016T16CM03176Residential Trade PermitComplete
2016T16CM02972Commercial Trade PermitComplete
2016T16DV02338RESIDENTIAL ZONINGNOVERIFY
2016T16DV00957EXCESSIVE INTERIOR STORAGECOMPLIAN
2016T15CM08675Residential Trade PermitComplete
2015T15CM06950Residential Trade PermitComplete
2015T15CM03948Commercial Trade PermitComplete
2015T15CM03963Commercial Trade PermitComplete
2015T15CM03353Commercial Trade PermitComplete
2015T15CM02112Commercial Trade PermitComplete
2015T15DV00743RES: MINIMUM HOUSINGNOVERIFY
2014T14CM08858Residential Trade PermitComplete
2014T14CM03934Residential Trade PermitComplete
2014T14CM01731Residential Trade PermitComplete
2014T14DV01203EMERGENCYNOVERIFY
2013T13CM04994Commercial Trade PermitComplete
2013T13DV05489MULTIPLE TYPESNOVERIFY
2012T12CM04871Residential Trade PermitComplete
2012T12CM02810Residential Trade PermitComplete
2011T11EL02908Commercial Trade PermitComplete
2011T11DV05206ENVIRONMENTALCOMPLIAN
2011T11DV03690RES: MINIMUM HOUSINGNOVERIFY
2011T11EL01338Commercial Trade PermitComplete
2011T11DV00976RES: MINIMUM HOUSINGCOMPLIAN
2010T10BU01517Residential Pool/Spa PermitComplete
2010T10PL00976Residential Trade PermitComplete
2010T10CM01646Residential Trade PermitCanceled
2010T10EL00616Residential Trade PermitComplete
2009T09PL01460Residential Trade PermitCanceled
2008T08PL01831Residential Trade PermitComplete
2008T08EL02296Residential Trade PermitWithdrawn
2008T08EL02297Residential Trade PermitCanceled
2008T08PL01790Commercial Trade PermitComplete
2008T08EL02168Commercial Trade PermitWithdrawn
2008T08EL02169Residential Trade PermitWithdrawn
2008T08PL01688Commercial Trade PermitComplete
2008T08PL01686Residential Trade PermitWithdrawn
2008T08CM00091Commercial Trade PermitComplete
2008T08EL01019Residential Trade PermitComplete
2008T08ME00283Residential Trade PermitComplete
2008T08PL00111Residential Trade PermitComplete
2008T08DV00322WORK WITHOUT PERMITS-RESIDENTLCOMPLIAN
2008T08EL00040Residential Trade PermitComplete
2006T06ME00558Residential Trade PermitComplete
2006T06ME00075Residential Trade PermitComplete
2005T05ME00399Residential Trade PermitCanceled
2005T05ME00356Residential Trade PermitCanceled
2005T05ME00221Residential Trade PermitCanceled
2004T04ME00714Residential Trade PermitCanceled
2004T04PL01490Residential Trade PermitComplete
2004T04PL00932Residential Trade PermitWithdrawn
2003T03EL02456Commercial Trade PermitComplete
2003T03EL01085Commercial Trade PermitComplete
2003T03PL00017Residential Trade PermitComplete
2002T02EL00871Commercial Trade PermitComplete
2002T02PL00025Residential Trade PermitCanceled
2001T01PL00860Residential Trade PermitComplete
2001T01ME00253Commercial Trade PermitCanceled
2000T00PL02516Residential Trade PermitCanceled
1998T98BU00856Residential Addition/Alteration PermitComplete
1998T98PL00355Residential Trade PermitCanceled

prints this report — permits, comparisons and sources — as a clean document

How this report was built

This is a reading of public records for parcel 135020080 — 73 City permits on file from 1998 to 2026 and 23 code enforcement cases — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive, whose records reach back to the mid-1990s. Some records were still not read for this snapshot: City permit records before the mid-1990s were never fully digitized. The construction year, living area, heating, roof, walls on this page come from our saved copy of the Assessor’s own published data file (dated 2026-01-28). The sewer connection file and the flood map were not read for this snapshot. Absence of a permit here is NOT evidence work was never permitted — it may predate the digitized record or sit in a system this snapshot did not read. Public records snapshot taken 2026-08-22.

The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.