Electrical permit history — 7042 E 3rd St

7042 E 3rd St, Tucson — built 1958, with 10 permits on record. Review electrical, HVAC and remodel history with links to official records.

Home

7042 E 3rd St

Built 1958 — post-war 60–100 A service era · last permitted panel/service work 2007 (finaled) · HVAC 2007 (finaled)

Parcel
133181140
Built
1958 (county record)
Jurisdiction
Tucson
Zoning
R-1
Assessor use
Sfr Grade 010-3 Urban Subdivided
Parcel size
0.29 acres
Living area
1,941 sq ft (assessor record)
Cooling
Refrigeration (assessor record)
Heating
Forced Air (assessor record)
Roof
Built Up (assessor record)
Garage
Carport (3-car) (assessor record)
Sewer
Connection on file (1972) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)
Typical original service for a 1958 home
approximately 60–100 A
Service on record
City records show the 2007 permit was finalized; the permit description states “panel upgrade to 200amps” — an increase in capacity as described, not a confirmed installed rating.

See the property

County aerial photograph centered on 7042 E 3rd St, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & panelCurrentLast permitted 2007 (19 years ago). City inspection record: PERMIT FINALED approved 2007-08-13. Contractor of record: ENERGY SOURCE ELECTRIC INC *C. The permit describes an increase in capacity, which is the single best sign the electrical has actually been brought forward. T07EL01104 — panel upgrade to 200amps
  • Heating & coolingLikely dueLast permitted 2007 (19 years ago). City inspection record: MECHANICAL - FINAL approved 2007-07-26. Contractor of record: RITE WAY VENTILATING CO , *C. The assessor records cooling as Refrigeration and heating as Forced Air. Cooling equipment works harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Equipment from before about 2010 generally runs R-22, which has not been produced since 2020 — repairs mean reclaimed refrigerant at a price that often exceeds replacing the unit. T07ME00368 — Replace existing furnace & cooler with 5 ton split system, gas electric
  • Water heaterNot in this windowNothing in the permit records we read for this parcel that names this system. Water heaters are frequently swapped without a permit, so this line is especially weak evidence either way.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. The assessor records the roof as Built Up.
  • Plumbing work on recordOn recordLast permitted 2013 (13 years ago). Plumbing permits cover everything from a full re-pipe to a few feet of sewer repair, so this is a record that work happened rather than a statement about the whole system. T13CM03803 — REPL INTERIOR WATER LINES;RESD

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    60–100 A was standard. That is enough for a mid-century house, not for a modern kitchen, HVAC, and an EV. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check — high priority

    Federal Pacific (Stab-Lok) and Zinsco/Sylvania panels were sold through this period. Stab-Lok breakers have a documented history of failing to trip internally; Zinsco breakers can weld to the bus so the handle moves without breaking the circuit. In both cases a replacement breaker does not resolve it — the panel itself is what gets replaced. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    Grounded branch circuits did not become the norm until the early 1960s — much of the original wiring here is likely ungrounded. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    Cloth-jacketed NM cable is common in this era. The jacket embrittles with age and heat, particularly in Tucson attics. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    Solar was permitted here in 2022. That means there is an existing interconnection, and the main breaker and busbar rating already carry a PV backfeed — so anything else you add (an EV charger, a heat pump) has to be checked against what is left under the 120% rule, not against the service size alone.

Recorded sales (1)

Recorded transfers from the Pima County Assessor — 1 of 1
DatePriceType
2014-08-15$155,000Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2022-07-27 (T22CM05700) — R - 19 Silfab 380 Solar Panel Installation 19 MODULES-ROOF MOUNTED - 7.22 kW DC, 5.51 kW AC, 7042 EAST 3RD STREET, TUCSON, AZ 85710 7042 East 3rd Street, Tucson, AZ 85710.

Permit history (10)

Permit history for this parcel — 8 of 10 records
DateRecordWhatStatusValue
2022-07-27finaledT22CM05700City permit recordSolar PVR - 19 Silfab 380 Solar Panel Installation 19 MODULES-ROOF MOUNTED - 7.22 kW DC, 5.51 kW AC, 7042 EAST 3RD STREET, TUCSON, AZ 85710 7042 East 3rd Street, Tucson, AZ 85710Final
2017-04-14finaledT17RW01662City permit recordROW(2) 5 X 5 IN DIRT IN REAR TO REPLACE GAS LINEFinal
2015-01-14finaledT15CM00253City permit recordCOMBOINTERIOR REMODEL (RES)Final
2013-06-24finaledT13CM03803City permit recordCOMBOREPL INTERIOR WATER LINES;RESDFinal
2007-08-09expired 2008-02-09T07EL01485City permit recordELECTpanel upgrade to 200ampsWithdrwn
2007-06-08T07EL01101City permit recordELECTpanel upgrade to 200ampsWithdrwn
2007-06-08T07EL01102City permit recordELECTpanel upgrade to 200ampsWithdrwn
2007-06-08T07EL01103City permit recordELECTpanel upgrade to 200ampsWithdrwn
Show 2 older records
Permit history for this parcel — remaining 2 records
DateRecordWhatStatusValue
2007-06-08finaledT07EL01104City permit recordELECTpanel upgrade to 200ampsFinal
2007-05-24finaledT07ME00368City permit recordMECHReplace existing furnace & cooler with 5 ton split system, gas electricFinal

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (1)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 1 of 1 records
DateRecordWhatStatus
2018-10-30T18DV07063Code enforcement caseCode enforcement caseComplian

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this home?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 133181140 — 10 permits on file from 2007 to 2022 (5 elect, 2 combo, 1 solar pv, 1 row) and 1 code enforcement case — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.