Electrical permit history — 1108 E Kentucky St
1108 E Kentucky St, Tucson — built 1962, with 7 permits on record. Review electrical, HVAC and remodel history with links to official records.
Home
1108 E Kentucky St
Built 1962 — post-war 60–100 A service era · last permitted panel/service work 2022 (permit expired without a confirmed final)
Permanent link: Electrical permit history for 1108 E Kentucky St (aztucsonelectricalsolutions.com/property/132181340/1108-e-kentucky-st-tucson-az-85714) · Public records last checked 2026-08-17
- Parcel
- 132181340
- Built
- 1962 (county record)
- Jurisdiction
- Tucson
- Zoning
- R-3
- Assessor use
- Condo/Twnhm/Row/Patio Grade 3
- Parcel size
- 0.08 acres
- Living area
- 816 sq ft (assessor record)
- Cooling
- Evaporative (assessor record)
- Heating
- Wall Furnace (assessor record)
- Roof
- Built Up (assessor record)
- Garage
- Carport (1-car) (assessor record)
- Sewer
- Connection on file (1962) (county sewer connection records)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
- Typical original service for a 1962 home
- approximately 60–100 A
- Service on record
- A 2022 permit expired without a confirmed final status; the permit description states “Installation of roof mounted 5.135kW photovoltaic system and a main panel upgrade” — an increase in capacity as described, not a confirmed installed rating.
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & panelPermitted — completion not confirmedA 2022 permit specifies this work (the permit description states “Installation of roof mounted 5.135kW photovoltaic system and a main panel upgrade”), but the available record does not show a final inspection. The permit expired without a confirmed final status. Official status: Expired. T22CM00489 — Installation of roof mounted 5.135kW photovoltaic system and a main panel upgrade
- Heating & coolingNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 addition / alteration permit is on file — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. The assessor records cooling as Evaporative and heating as Wall Furnace. Cooling equipment works harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes.
- Water heaterNot in this windowNothing in the permit records we read for this parcel that names this system. Water heaters are frequently swapped without a permit, so this line is especially weak evidence either way.
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. The assessor records the roof as Built Up.
- Plumbing work on recordNot in this windowNothing in the permit records we read for this parcel that names this system. Unremarkable — plenty of buildings never need a permitted plumbing repair.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check — high priority
60–100 A was standard. That is enough for a mid-century house, not for a modern kitchen, HVAC, and an EV. The permit record does not confirm this; an on-site inspection is required.
- Era-based check — high priority
Federal Pacific (Stab-Lok) and Zinsco/Sylvania panels were sold through this period. Stab-Lok breakers have a documented history of failing to trip internally; Zinsco breakers can weld to the bus so the handle moves without breaking the circuit. In both cases a replacement breaker does not resolve it — the panel itself is what gets replaced. The permit record does not confirm this; an on-site inspection is required.
- Era-based check
Grounded branch circuits did not become the norm until the early 1960s — much of the original wiring here is likely ungrounded. The permit record does not confirm this; an on-site inspection is required.
- Era-based check
Cloth-jacketed NM cable is common in this era. The jacket embrittles with age and heat, particularly in Tucson attics. The permit record does not confirm this; an on-site inspection is required.
Most recent permit on record for this parcel: 2025-06-23 (TC-RES-0625-03167) — - Requesting Reconnection for Electricity & Gas services. Also, to acquire the Occupancy Certificate to return to the home..
Permit history (7)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2025-06-23finaled | TC-RES-0625-03167City permit record | Residential Building - One or Two Family- Requesting Reconnection for Electricity & Gas services. Also, to acquire the Occupancy Certificate to return to the home. | Complete | |
| 2025-06-20finaled | TC-DMO-0625-00131City permit record | Addition / alterationRemoval of unpermitted structure/addition | Inspections complete | |
| 2025-05-02 | TC-RES-0525-02338City permit record | Residential Building - One or Two FamilyVOID: Wrong Permit Type. Continue with TC-RES-0425-02290 Inspect building violations | Void | |
| 2025-04-30 | TC-RES-0425-02290City permit record | Residential Building - One or Two FamilyBuilding permit to address all violations | Withdrawn | |
| 2025-04-29expired 2025-05-29 | SP-NRP-0425-00217City permit record | SimpleDENIED, WRONG PERMIT TYPE DUE TO CODE ENFORCEMENT CASE CE-VIO0425-01432, YOU WILL NEED A BUILDING PERMIT TO ADDRESS ALL VIOLATIONS I would like to get this permit so TEP can install Power back for home ower | Denied | |
| 2022-01-21 | T22CM00489City permit record | Residential Building - One or Two FamilyInstallation of roof mounted 5.135kW photovoltaic system and a main panel upgrade | Expired | |
| 2021-10-27expired 2022-05-18 | T21CM08453City permit record | COMBOInstall of roof mounted 4.950 dc kw photovoltaic system. | Withdrwn |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (2)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2025-04-07 | CE-VIO0425-01432Code enforcement case | Electrical | Closed - resolved |
| 2010-07-08 | T10DV04459Code enforcement case | Code enforcement case | Noverify |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Planning work at this home?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, sent once. No list.One email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list.
How this report was built
This is a reading of public records for parcel 132181340 — 7 permits on file from 2021 to 2025 (4 residential building - one or two family, 1 addition / alteration, 1 simple, 1 combo) and 2 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.