Electrical permit history — 2025 S Camilla Sv
2025 S Camilla Sv, Tucson — built 1955, with 8 permits on record. Review electrical, HVAC and remodel history with links to official records.
Home
2025 S Camilla Sv
Built 1955 — post-war 60–100 A service era · last permitted panel/service work 2011 (finaled)
Permanent link: Electrical permit history for 2025 S Camilla Sv (aztucsonelectricalsolutions.com/property/130110240/2025-s-camilla-sv-tucson-az-85713) · Public records last checked 2026-08-17
- Parcel
- 130110240
- Built
- 1955 (county record)
- Jurisdiction
- Tucson
- Zoning
- R-1
- Assessor use
- Sfr Grade 010-3 Urban Subdivided
- Parcel size
- 0.19 acres
- Living area
- 1,514 sq ft (assessor record)
- Cooling
- Evaporative (assessor record)
- Heating
- Forced Air (assessor record)
- Roof
- Asphalt (assessor record)
- Pool
- Yes (assessor record)
- Sewer
- Connection on file (1955) (county sewer connection records)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
- Typical original service for a 1955 home
- approximately 60–100 A
- Service on record
- City records show the 2011 permit was finalized; the permit description states “UPGRADE ELECTRIC TO 200 AMPS” — an increase in capacity as described, not a confirmed installed rating.
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & panelCurrentLast permitted 2011 (15 years ago). City inspection record: ELECTRIC - FINAL approved 2011-06-16. Contractor of record: G P ELECTRICAL SERVICES INC. The permit describes an increase in capacity, which is the single best sign the electrical has actually been brought forward. T11EL01627 — UPGRADE ELECTRIC TO 200 AMPS
- Heating & coolingNot in this windowNothing in the permit records we read for this parcel that names this system. The assessor records cooling as Evaporative and heating as Forced Air. Cooling equipment works harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes.
- Water heaterNot in this windowNothing in the permit records we read for this parcel that names this system. Water heaters are frequently swapped without a permit, so this line is especially weak evidence either way.
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. The assessor records the roof as Asphalt.
- Plumbing work on recordNot in this windowNothing in the permit records we read for this parcel that names this system. Unremarkable — plenty of buildings never need a permitted plumbing repair.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check — high priority
60–100 A was standard. That is enough for a mid-century house, not for a modern kitchen, HVAC, and an EV. The permit record does not confirm this; an on-site inspection is required.
- Era-based check — high priority
Federal Pacific (Stab-Lok) and Zinsco/Sylvania panels were sold through this period. Stab-Lok breakers have a documented history of failing to trip internally; Zinsco breakers can weld to the bus so the handle moves without breaking the circuit. In both cases a replacement breaker does not resolve it — the panel itself is what gets replaced. The permit record does not confirm this; an on-site inspection is required.
- Era-based check
Grounded branch circuits did not become the norm until the early 1960s — much of the original wiring here is likely ungrounded. The permit record does not confirm this; an on-site inspection is required.
- Era-based check
Cloth-jacketed NM cable is common in this era. The jacket embrittles with age and heat, particularly in Tucson attics. The permit record does not confirm this; an on-site inspection is required.
- Worth confirming
The assessor records a pool on this parcel. Equipment bonding, the equipotential bonding grid and GFCI protection on the pump and light circuits are the usual findings on pool equipment — the pool-bonding rules in NEC Article 680 were expanded in the 2008 cycle, so a pool built before that is worth an on-site check.
Most recent permit on record for this parcel: 2026-06-25 (TC-RES-0626-03473) — Install water softener carbon filtration combo system.
Permit history (8)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2026-06-25finaled | TC-RES-0626-03473City permit record | Residential Building - One or Two FamilyInstall water softener carbon filtration combo system | Complete | |
| 2025-08-25 | TC-RES-0825-04215City permit record | Fence / wallConverting existing bedroom into a second bathroom and linen closet both with access located in the hallway. Separating of bedroom into the two areas will be constructed as a non-loadbearing wall in the middle, as shown in the new layout diagram. | Expired | |
| 2025-01-29expired 2025-02-28 | SP-NRP-0125-00047City permit record | Electrical reconnect*VOID - Existing work permit. Complete Inspections or Sub-Record on Active Permit (The City of Tucson has not approved your Electrical Reconnect Only request. Our records indicate a permit for electrical work at this location exists under permit application TC-RES-0125-00570. This type of permit is for electric reconnection of occupiable buildings after a period of depowered status where no electrical work will be done. Please continue your electrical reconnect request through your existing permit TC-RES-0125-00570.)* - - Electrical power has been turned off for more than a year. Home owner is looking at moving back in and needs a panel inspection for TEP to turn power back on. Panel is a 200amp panel grounded with two ground rods and bonded to the main water pipe. - - | Denied | |
| 2025-01-29expired 2026-04-13 | TC-RES-0125-00570City permit record | Addition / alterationWe are removing old none grounded wire and running new wire with ground. GFCI protected circuits are being added to the bathroom and to the kitchen. Dedicated circuit for smoke detectors will be added also. No additional outlets have been added, electrical layout is the same, we are just running new grounded wire. MC cable is being used in areas that will be covered by plaster. Attached is a schematic of the home with panel schedule and load calculations. Nothing is being done to current 200amp panel. Panel is to remain the same. Old fused sub panel is being removed And all load circuits are directed to main panel. | Inspections | |
| 2024-10-18expired 2024-11-17 | SP-NRP-1024-00061City permit record | SimplePower needs to be reconnected after extended time of not being connected. | Expired | |
| 2024-10-17expired 2025-04-22 | TC-RES-1024-06064City permit record | Addition / alterationMy Plumber will run new Wirsbo Aqua Pex through-out home to replace failing water supply system. My Plumber will run new water lines to kitchen to include new emergency shut off valves, supply lines as well as refrigerator box. My Plumber will run new lines to washing machine that will include a washer box with new valves. My Plumber will run new water lines to existing bathroom that will include new supply lines and emergency shut off valves to sink and toilet. My Plumber will install new diverter to shower. My Plumber will also install water lines to an additional bathroom that will be added in the future that will be capped and ready for use when home owner is ready. My Plumber will install two new hose bibs, one in front of home that will include an emergency shut off valve and one in back yard. My Plumber will test home water pressure to determine if home needs a pressure regulator valve that maintains positive water flow. AND: My Plumber will run new natural gas line throughout home to replace gas line that has failed. My Plumber will run new black-iron piping from meter in back of home to tankless water heater, range, HVAC and dryer. My Plumber will include new emergency shut off valves at each unit as well as new flex lines and sediment traps as needed. | Inspections | |
| 2024-01-23expired 2024-10-02 | TC-RES-0124-00400City permit record | Addition / alterationRemodel SFR and Porch Additions | Expired | |
| 2011-06-13finaled | T11EL01627City permit record | ELECTUPGRADE ELECTRIC TO 200 AMPS | Final |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (1)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2021-09-23 | T21DV06713Code enforcement case | Code enforcement case | Noverify |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Planning work at this home?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, sent once. No list.One email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list.
How this report was built
This is a reading of public records for parcel 130110240 — 8 permits on file from 2011 to 2026 (3 addition / alteration, 1 residential building - one or two family, 1 fence / wall, 1 electrical reconnect) and 1 code enforcement case — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.
