Electrical permit history — 1776 S Palo Verde Av

1776 S Palo Verde Av, Tucson — built 1962, with 118 permits on record. Review electrical, HVAC and remodel history with links to official records.

Electrical Property Screening Report · Home

1776 S Palo Verde Av

A screening report for electrical planning, assembled from public-record indicators. It is not an official record and every figure in it should be verified against the issuing agency before it is relied on.

Verify parcel data at official source ↗

Built 1962 — post-war 60–100 A service era · HVAC 2021 (finaled); a newer 2023 permit is issued

Is it time to upgrade?

  • Electrical service & panelNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2017 addition / alteration permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Nothing permitted on the service shows in the record we read. For a home built in 1962 that leaves the original service era in play — the panel makes and wiring methods of that era are exactly what the era check above flags, and only a look at the panel settles it.
  • Heating & coolingFinaled permit foundA newer 2023 permit for the same system is recorded as “Issued” — The work was permitted, but final completion is not confirmed. The permit description states “install new mini split”. Last permitted 2021 (5 years ago). The assessor records cooling as Evaporative. Cooling equipment works harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. T21CM03319 — Remove swamp cooler and replace with 2 zone mini split
  • Water heaterFinaled permit foundLast permitted 2021 (5 years ago). T21CM09737 — Replace 40 gal gas water heater like for like same location
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. The assessor records the roof as Composition Shingle.
  • Plumbing work on recordOn recordLast permitted 2000 (26 years ago). Plumbing permits cover everything from a full re-pipe to a few feet of sewer repair, so this is a record that work happened rather than a statement about the whole system. T00PL00330 — WATER LINE:REPLACE

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitized. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    60–100 A was standard. That is enough for a mid-century house, not for a modern kitchen, HVAC, and an EV. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check — high priority

    Federal Pacific (Stab-Lok) and Zinsco/Sylvania panels were sold through this period. Stab-Lok breakers have a documented history of failing to trip internally; Zinsco breakers can weld to the bus so the handle moves without breaking the circuit. In both cases a replacement breaker does not resolve it — the panel itself is what gets replaced. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    Grounded branch circuits did not become the norm until the early 1960s — much of the original wiring here is likely ungrounded. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    Cloth-jacketed NM cable is common in this era. The jacket embrittles with age and heat, particularly in Tucson attics. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    There is an electrical reconnect permit from 2025. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.

  • Routine

    A trade permit was pulled in 2026. Trade permits cover electrical, plumbing, and mechanical work individually, so some permitted trade work has been done here since.

What to check at the panel

Everything above is read off public records. These are the things only someone standing at the panel can settle, and they take about a minute.

  1. The number stamped on the main breaker handle — 100, 125, 150, 175 or 200. That is the service rating, and no record on this page confirms it.
  2. The busbar rating printed on the panel label. It is a different number from the main breaker, and it is the one that decides how much solar a panel can take under the 120% rule.
  3. The manufacturer and catalog number on the label inside the door.
  4. How many full-size spaces are left, how many positions the label permits a tandem breaker in, and the tandem limit the label states. A full panel is a different job from a full service.
  5. The conductor material at the main lugs, and whether the terminations look clean and tight.
  6. Whether there is a separate meter-main outside as well as the panel indoors — that changes where a disconnect and any new feeder would land.
  7. Whether the water heater, dryer and range are gas or electric. No public record carries fuel type, and it is the single biggest variable in a load calculation — it can move the calculated load on the same house by more than 40 A.
  8. The brand on the door or the breaker faces. Federal Pacific panels usually read “Federal Pacific Electric” or “FPE”; Zinsco panels read “Zinsco”, or on later stock “Sylvania” or “Sylvania-Zinsco”. Finding a Square D, Eaton, Cutler-Hammer, Siemens or GE panel here is the ordinary result and is not a finding — those are current, supported lines with breakers on the shelf.
  9. Whether receptacles are two-prong, and whether any three-prong replacements have an actual ground behind them. A $10 tester answers this at every outlet.
  10. Whether the kitchen counter, bathroom, garage and exterior receptacles have GFCI protection, and whether the test button actually trips them.

With those in hand you can run the numbers yourself. The load calculator does the NEC 220.82 optional-method calculation — the same method a permit application uses — and shows its work.

Open the load calculator →

What these jobs cost here

The cooling equipment here was permitted in 2021 — replacement is not due yet.

Electrical panel or service upgrade

$3,800

Most jobs like this land between $3,400 and $4,700.

The bottom of this range is a clean, simple job: single storey, framed wall, the panel staying where it is, a short service run, and nothing unexpected once the cover comes off. That job is real and we do book it — but it is the best case, not the average, and the figure above it is what most houses actually come to.

Priced from built 1962 (post-war 60–100 A service era), City of Tucson permit fee and the 2023 NEC it has adopted, Tucson Electric Power as the serving utility and framed walls on the assessor record, so no masonry drilling or stucco patch is priced.

What would move this price
  • Only if the panel has to move — a clothes closet, a bathroom, over a stairway, or behind a door +$3,900
  • Only if the mast is undersized or corroded — common at this age +$1,300
  • Only if the metal water and gas piping are not already bonded — usually not, at this age +$600
  • Only if the original fuse or split-bus panel is still in service +$1,700

If every one of those turned out to apply, this becomes about $12,100. That is the worst realistic case, not a prediction — none of them is a claim about your house.

Before you spend anything
  • A service upgrade fixes capacity and the safety of the service equipment. It does not fix branch wiring. If the reason you are here is flickering lights, warm outlets or cloth-jacketed wiring, an upgrade is a down payment on a much bigger problem, and it is worth knowing that before you spend in the wrong order. (The report reserves the era-specific wiring checks for the years they actually apply to — read those above.)
  • You may not need the upgrade at all. NEC 220.87 lets an existing dwelling be sized from twelve months of actual metered demand rather than a calculated load, and real houses draw far less than the calculation predicts. Ask your utility for a year of interval data and have it run that way first. Two cautions so this does not backfire: the demand tile in a TEP online account shows on-peak demand only, which is not the annual maximum the code asks for — you want the formal usage-data release — and 220.87 proves CAPACITY and nothing else. It does not create empty breaker spaces, and it does not make an obsolete panel, or one whose breakers have a documented failure history, safe. Those are separate questions with separate answers — and where the era makes a brand worth checking, the report above says so on its own.

A finalled HVAC permit from 2021 is on record, so the equipment is inside its expected life and we are not pricing a replacement.

What the record cannot tell us
  • Whether the service is already 200 A. Nothing in the public record says so, and the number is stamped on the main breaker handle.
  • Whether the panel can stay where it is. A panel in a closet, over stairs or behind a door has to move, and that alone adds $1,500 to $5,000.
  • Whether the service comes in overhead or underground. This is priced as overhead; an underground service with an adequate lateral is a few hundred dollars cheaper, and one with an undersized lateral is thousands more.

This is an estimate, not a quote. It is built from this property’s public record and current City of Tucson market rates — nobody has seen your panel, your duct or your roof. A real price comes from a site visit, and the things that move it most are the ones listed above that no record carries.

Price it for your house →

Change the assumptions — the panel’s location, the duct, the tonnage, whether the service is overhead or underground — and watch the number move. That is the point of it.

Solar potential

The county’s building-footprint layer maps ≈ 24,958 sq ft of roof plan area here across 4 structures. In Tucson a rooftop array produces about 1,645 kWh per installed kW per year (PVWatts), so a typical 6–8 kW home system fits on a fraction of that roof and makes roughly 10,000–13,000 kWh a year. TEP credits exported surplus at its RCP rate — about 5¢/kWh for new applications, locked for 10 years — so sizing to the home’s own use matters more than filling the roof. If solar shows in this property’s permit record, check whether it was permitted and finaled.

Flood and drainage

The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.

The record behind this read

Parcel
130083910
Year constructed
1962 (county record)
Permitting authority
Tucson
Zoning
R-3
Living area
34,617 sq ft
Cooling
Evaporative
Estimated electrical service era
approximately 60–100 A (estimated from the year built, 1962 — not a measurement; verify on site)

The living area and cooling above come from the Pima County Assessor’s record, as we read it on 28 Jan 2026. Each other row names its own source.

The most recent permitted work on this parcel was in 2026. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What this means for work here

Informational public-record summary — not engineering, inspection, valuation or purchasing advice, and not the official record.

The most recent permitted work on this parcel was in 2026. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What that reading rests on. The issuing offices hold 118 building permits for this parcel dated between 1997 and 2026. By category the work is trade permit (90), addition / alteration (21), electrical reconnect (3) and right-of-way (row) permit - utility emergency (2). 79 of them carry a final inspection; the other 39 were issued, expired or are still open, which is not the same as work completed. There are 21 code-enforcement cases recorded against the parcel, all of them closed. We do not reproduce complaint text — it routinely names people with no connection to the property.

Go straight to the records

Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.

Read the records yourself. We republish selected facts and record numbers so you can find the file; the issuing agency’s record controls. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 130083910. Permit and parcel information courtesy of the City of Tucson and Pima County; their files are the official record and control over anything summarized here.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.

In the public record: All homes in 85713 · Homes by ZIP code · Commercial property in 85713 · Permit data by neighborhood

Planning work at this home?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

What the flood note is not. The FEMA map linked above is the National Flood Hazard Layer — the federal insurance map. Local floodplain mapping is not reproduced here; use the authority’s own map, linked above. Nothing here is a floodplain determination, an elevation certificate, or a substitute for one. A parcel can straddle a boundary, and a Letter of Map Amendment can remove a structure the map still covers. For a determination, ask the floodplain administrator for the jurisdiction named above; for a design that has to satisfy one, that is work we do.

How this property compares nearby

Built in 1962 — earlier than about 61% of the 13,135 homes in ZIP 85713. 34,617 sq ft of living area — above this ZIP’s median of 1,243 sq ft. About 49% of homes in this ZIP still cool with evaporative — this one is among them, which matters when sizing a panel for future refrigerated AC. Properties on S PALO VERDE AV hold 314 City permits on record, 70 of them since 2022.

Computed from the same public records as this report — counts and years, not an appraisal.

Complete permit record (139 entries)

Every permit and case we hold for this parcel, newest first. Each number links to the official file.

YearNumberTypeStatus
2026TC-RES-0826-04857Residential Trade PermitNeeds Resubmittal
2026recordRight-of-Way (ROW) Permit - Utility EmergencyVoid
2026TC-RES-0426-01723Residential Trade PermitWithdrawn
2026TC-COM-0226-00191Commercial Trade PermitComplete
2026TC-COM-0226-00192Commercial Trade PermitComplete
2026TC-COM-0226-00194Commercial Trade PermitComplete
2026TC-COM-0226-00193Commercial Trade PermitComplete
2025TC-COM-1025-01999Commercial Trade PermitInspections
2025SP-NRP-1025-00430Electrical ReconnectInspections
2025TC-COM-0925-01721Commercial Trade PermitInspections
2025SP-NRP-0425-00212Electrical ReconnectComplete
2025TC-COM-1224-02361Commercial Trade PermitIssued
2023TC-COM-1123-02701Commercial Trade PermitIssued
2023TC-RES-1123-09238Electrical ReconnectExpired
2023TC-RES-0823-07681Residential Trade PermitIssued
2023TC-COM-0823-01903Commercial Trade PermitIssued
2023CE-VIO0623-04130VegetationClosed - Unfounded
2023TC-RES-0323-03635Residential Trade PermitIssued
2023recordRight-of-Way (ROW) Permit - Utility EmergencyComplete
2022TC-RES-1122-00796Residential Trade PermitIssued
2022T22CM04194Commercial Trade PermitComplete
2022T22CM03978Commercial Trade PermitComplete
2022T22DV02447ANIMAL ISSUESCOMPLIAN
2021T21CM09737Commercial Trade PermitComplete
2021T21CM08109Commercial Trade PermitComplete
2021T21CM03319Commercial Trade PermitComplete
2020T20DV07610REFUSECOMPLIAN
2020T20CM06410Residential Trade PermitExpired
2020T20DV03840RES: MINIMUM HOUSINGNOVERIFY
2019T19CM09474Commercial Trade PermitComplete
2019T19CM04377Commercial Trade PermitComplete
2019T19CM03154Commercial Trade PermitComplete
2019T19CM02261Commercial Trade PermitComplete
2019T19CM01468Commercial Trade PermitComplete
2018T18CM09282Commercial Trade PermitComplete
2018T18CM07775Commercial Addition/Alteration PermitCanceled
2018T18CM07138Commercial Trade PermitCanceled
2018T18DV02974RES: MINIMUM HOUSINGNOVERIFY
2018T18CM03693Commercial Trade PermitComplete
2018T18DV01616EXCESSIVE INTERIOR STORAGENOVERIFY
2018T18CM00448Residential Trade PermitCanceled
2018T18CM00043Residential Trade PermitCanceled
2017T17CM07373Residential Trade PermitComplete
2017T17CM06185Commercial Addition/Alteration PermitComplete
2017T17CM06186Commercial Trade PermitComplete
2017T17DV02875EMERGENCYCOMPLIAN
2017T17DV02882FIRE AT COMMERCIAL BUILDINGCOMPLIAN
2017T17DV02885FIRE AT COMMERCIAL BUILDINGCOMPLIAN
2017T17CM00508Commercial Trade PermitComplete
2016T16CM09040Residential Trade PermitCanceled
2016T16CM07910Residential Trade PermitComplete
2016T16CM03516Commercial Trade PermitComplete
2016T16CM02512Commercial Trade PermitComplete
2016T16CM02433Residential Trade PermitComplete
2016T16DV00063MULTIPLE TYPESCOMPLIAN
2015T15CM07067Commercial Trade PermitComplete
2015T15DV02488FIRE AT COMMERCIAL BUILDINGCOMPLIAN
2014T14CM04818Commercial Trade PermitCanceled
2014T14CM03236Residential Trade PermitComplete
2013T13CM07666Residential Trade PermitComplete
2013T13CM06727Commercial Trade PermitComplete
2013T13CM03846Residential Trade PermitComplete
2013T13DV03779REFUSENOVERIFY
2013T13DV02423MULTIPLE TYPESCOMPLIAN
2012T12CM07723Commercial Trade PermitComplete
2012T12DV03558EMERGENCYCOMPLIAN
2012T12DV03560EMERGENCYCOMPLIAN
2012T12DV03566EMERGENCYCOMPLIAN
2011T11CM02483Commercial Addition/Alteration PermitComplete
2011T11ME00193Residential Trade PermitComplete
2011T11DV05089RES: MINIMUM HOUSINGCOMPLIAN
2010T10EL02849Commercial Trade PermitComplete
2010T10CM03459Commercial Addition/Alteration PermitCanceled
2010T10DV04481RES: MINIMUM HOUSINGNOVERIFY
2010T10BU00467Commercial Fence/Wall PermitComplete
2010T10BU00435Commercial Fence/Wall PermitWithdrawn
2010T10CM00240Residential Addition/Alteration PermitComplete
2010T10PL00175Residential Trade PermitComplete
2010T10EL00014Residential Trade PermitComplete
2009T09PL00704Residential Trade PermitComplete
2009T09EL00769Residential Trade PermitComplete
2009T09CM00409Residential Addition/Alteration PermitCanceled
2009T09DV00753WORK WITHOUT PERMITS-RESIDENTLINVALID
2008T08DV08734RES: MINIMUM HOUSINGNOVERIFY
2008T08EL00704Residential Trade PermitComplete
2008T08EL00634Commercial Trade PermitComplete
2008T08DV00865LIGHTING VIOLATIONCANCEL
2006T06PL01301Commercial Trade PermitComplete
2006T06EL01184Commercial Trade PermitComplete
2006T06CM01408Commercial Trade PermitComplete
2005T05EL01923Residential Trade PermitComplete
2005T05EL01743Residential Trade PermitComplete
2005T05EL01679Commercial Trade PermitComplete
2005T05CM03872Residential Addition/Alteration PermitComplete
2005T05EL00947Residential Trade PermitComplete
2005T05EL00005Residential Trade PermitComplete
2004T04BU01716Commercial Addition/Alteration PermitCanceled
2004T04BU01717Commercial Addition/Alteration PermitCanceled
2004T04BU01718Commercial Addition/Alteration PermitCanceled
2004T04EL00718Commercial Trade PermitComplete
2004T04CM01316Residential Addition/Alteration PermitCanceled
2004T04CM01255Commercial Trade PermitComplete
2003T03EL02243Commercial Trade PermitComplete
2003T03ME00619Residential Trade PermitComplete
2003T03CM05158Residential Addition/Alteration PermitWithdrawn
2003T03CM04755Residential Trade PermitComplete
2003T03BU00920Commercial Addition/Alteration PermitCanceled
2003T03CM01795Commercial Addition/Alteration PermitComplete
2002T02PL02372Residential Trade PermitComplete
2002T02PL01541Residential Trade PermitComplete
2002T02EL00247Residential Trade PermitComplete
2001T01EL01725Residential Trade PermitComplete
2001T01EL00815Residential Trade PermitComplete
2001T01PL00755Commercial Trade PermitCanceled
2000T00EL02575Residential Trade PermitComplete
2000T00BU01958Residential Addition/Alteration PermitComplete
2000T00PL00330Commercial Trade PermitComplete
1999T99EL00492Residential Trade PermitComplete
1999T99PL00478Commercial Trade PermitComplete
1999T99PL00294Residential Trade PermitComplete
1999T99EL00052Residential Trade PermitComplete
1998T98BU01179Residential Addition/Alteration PermitComplete
1998T98BU01188Residential Addition/Alteration PermitWithdrawn
1998T98EL00671Residential Trade PermitComplete
1998T98PL00772Commercial Trade PermitCanceled
1998T98PL00702Commercial Trade PermitComplete
1998T98ME00207Commercial Trade PermitCanceled
1998T98CM01192Residential Trade PermitCanceled
1998T98EL00029Commercial Trade PermitComplete
1998T98EL00014Commercial Trade PermitComplete
1997T97CM03220Residential Trade PermitCanceled
1997T97BU01907Residential Addition/Alteration PermitComplete
1997T97BU01908Residential Addition/Alteration PermitComplete
1997T97BU01909Residential Addition/Alteration PermitComplete
1997T97CM02722Residential Trade PermitCanceled
1997T97EL01054Residential Trade PermitCanceled
1997T97PL00899Residential Trade PermitCanceled
1997T97BU01275Residential Addition/Alteration PermitCanceled
1997T97PL00026Residential Trade PermitComplete

prints this report — permits, comparisons and sources — as a clean document

How this report was built

This is a reading of public records for parcel 130083910 — 118 City permits on file from 1997 to 2026 and 21 code enforcement cases — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive, whose records reach back to the mid-1990s. Some records were still not read for this snapshot: City permit records before the mid-1990s were never fully digitized. The construction year, living area, cooling, roof, walls on this page come from our saved copy of the Assessor’s own published data file (dated 2026-01-28). The sewer connection file and the flood map were not read for this snapshot. Absence of a permit here is NOT evidence work was never permitted — it may predate the digitized record or sit in a system this snapshot did not read. Public records snapshot taken 2026-09-22.

The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.