Electrical permit history — 4009 E Paseo Grande

4009 E Paseo Grande, Tucson — built 1957, with 14 permits on record. Review electrical, HVAC and remodel history with links to official records.

Home

4009 E Paseo Grande

Built 1957 — post-war 60–100 A service era · last permitted panel/service work 2026 (finaled); a newer 2026 permit is issued

Parcel
126180510
Built
1957 (county record)
Jurisdiction
Tucson
Zoning
R-1
Assessor use
Sfr Grade 010-3 Urban Subdivided
Parcel size
0.31 acres
Living area
1,653 sq ft (assessor record)
Cooling
Refrigeration (assessor record)
Heating
Forced Air (assessor record)
Roof
Built Up (assessor record)
Pool
Yes (assessor record)
Garage
Carport (2-car) (assessor record)
Sewer
Connection on file (1957, 2006) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)
Typical original service for a 1957 home
approximately 60–100 A
Service on record
City records show the 2026 permit was finalized; the permit description states “Install two meter pack with two 200 amp meters: Replace unit 1 service with 200 amp main breaker panel.”.

See the property

County aerial photograph centered on 4009 E Paseo Grande, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & panelCurrentA newer 2026 permit for the same system is recorded as “Inspections” — The work was permitted, but final completion is not confirmed. The permit description states “Install 200 amp service”. Last permitted this year (2026). City inspection record: COT - RSEL - Electrical Final approved 2026-03-18. Worth reading the permit itself: it names the service but does not read as an increase in capacity, so this may have been a like-for-like replacement rather than an upgrade. TC-RES-0126-00254 — Install two meter pack with two 200 amp meters: Replace unit 1 service with 200 amp main breaker panel.
  • Heating & coolingNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 adu / casita permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. The assessor records cooling as Refrigeration and heating as Forced Air. Cooling equipment works harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes.
  • Water heaterNot in this windowNothing in the permit records we read for this parcel that names this system. Water heaters are frequently swapped without a permit, so this line is especially weak evidence either way.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. The assessor records the roof as Built Up.
  • Plumbing work on recordNot in this windowNothing in the permit records we read for this parcel that names this system. Unremarkable — plenty of buildings never need a permitted plumbing repair.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    60–100 A was standard. That is enough for a mid-century house, not for a modern kitchen, HVAC, and an EV. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check — high priority

    Federal Pacific (Stab-Lok) and Zinsco/Sylvania panels were sold through this period. Stab-Lok breakers have a documented history of failing to trip internally; Zinsco breakers can weld to the bus so the handle moves without breaking the circuit. In both cases a replacement breaker does not resolve it — the panel itself is what gets replaced. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    Grounded branch circuits did not become the norm until the early 1960s — much of the original wiring here is likely ungrounded. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    Cloth-jacketed NM cable is common in this era. The jacket embrittles with age and heat, particularly in Tucson attics. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    The assessor records a pool on this parcel. Equipment bonding, the equipotential bonding grid and GFCI protection on the pump and light circuits are the usual findings on pool equipment — the pool-bonding rules in NEC Article 680 were expanded in the 2008 cycle, so a pool built before that is worth an on-site check.

  • Worth confirming

    An ADU or casita was permitted in 2025, which means load has already been added to this property. Whether there is headroom left for anything more depends on how that was fed — a subpanel off the existing service, or its own.

  • Worth confirming

    Solar was permitted here in 2017. That means there is an existing interconnection, and the main breaker and busbar rating already carry a PV backfeed — so anything else you add (an EV charger, a heat pump) has to be checked against what is left under the 120% rule, not against the service size alone.

Recorded sales (1)

Recorded transfers from the Pima County Assessor — 1 of 1
DatePriceType
2010-04-15$207,500Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2026-03-06 (TC-RES-0326-01155) — Install 200 amp service.

Permit history (14)

Permit history for this parcel — 8 of 14 records
DateRecordWhatStatusValue
2026-03-06expires 2026-09-09TC-RES-0326-01155City permit recordResidential Building - One or Two FamilyInstall 200 amp serviceInspections
2026-01-23TC-RES-0126-00361City permit recordResidential Building - One or Two FamilyVOID: - Same scope of work as existing application permit TC-RES-0126-00254. Please resubmit under existing permit. Install meter pack w/ two 200 Amp meters: one for each unit. Replace unit 1 service with main breaker sub panel.Void
2026-01-19finaledTC-RES-0126-00254City permit recordResidential Building - One or Two FamilyInstall two meter pack with two 200 amp meters: Replace unit 1 service with 200 amp main breaker panel.Complete
2025-04-30finaledTC-RES-0425-02304City permit recordADU / casitaReplace Carport with Bedroom Suite and Second Story ADUInspections complete
2017-09-12finaledT17CM06967City permit recordSolar PVSOLARFinal
2011-09-27finaledT11BU01236City permit recordPool / spaADD; POOLFinal
2011-09-27finaledT11OT01849City permit recordPool / spaFLOODPLAIN USE PERMIT: Pool electrical EquipmentFinal
2011-09-16finaledT11BU01182City permit recordFence / wallADDT: 6' H X 100LFFinal
Show 6 older records
Permit history for this parcel — remaining 6 records
DateRecordWhatStatusValue
2011-05-23finaledT11OT01017City permit recordFLOODPLNFLOODPLAIN USE PERMIT (T11CM01348) COMPLIANCE:ENCLOSE:CARPORT FOR STROAGE T11DV02197Final
2011-05-03finaledT11CM01348City permit recordCOMBOCODE COMPLIANCE:ENCLOSE:CARPORT FOR STROAGE T11DV02197Final
2009-08-31T09AN00494City permit recordADDRNEWIssued
2004-06-17finaledT04CM02794City permit recordCOMBOREMODEL:BATHFinal
2004-02-18expired 2004-12-19T04ME00072City permit recordMECHMECHANICAL:SPLIT SYSTEMExpired
2003-09-25finaledT03PL01571City permit recordPLUMBINSTALL:POTABLE WATERLINEFinal

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (1)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 1 of 1 records
DateRecordWhatStatus
2011-04-05T11DV02197Code enforcement caseCode enforcement caseComplian

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this home?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 126180510 — 14 permits on file from 2003 to 2026 (3 residential building - one or two family, 2 pool / spa, 2 combo, 1 adu / casita) and 1 code enforcement case — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.