Electrical permit history — 303 S Santa Rita Av

303 S Santa Rita Av, Tucson — built 1984, with 14 permits on record. Review electrical, HVAC and remodel history with links to official records.

Home

303 S Santa Rita Av

Built 1984 — FPE/Zinsco panel era · HVAC 2008 (finaled)

Parcel
124121740
Built
1984 (county record)
Jurisdiction
Tucson
Zoning
R-2
Assessor use
Duplex - 1 Story
Parcel size
0.10 acres
Sewer
No connection on file (sewer or septic status not confirmed by the record — verify on site)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)
Typical original service for a 1984 home
approximately 100–150 A

See the property

County aerial photograph centered on 303 S Santa Rita Av, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & panelNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2022 row permit is on file — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not tell you the service is original — only that nothing has been permitted here recently. The build year is the better clue, and it is above.
  • Heating & coolingLikely dueLast permitted 2008 (18 years ago). City inspection record: MECHANICAL - FINAL approved 2008-12-09. Contractor of record: HEATWAVE REFRIGERATION & AIR*T. Cooling equipment works harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Equipment from before about 2010 generally runs R-22, which has not been produced since 2020 — repairs mean reclaimed refrigerant at a price that often exceeds replacing the unit. T08CM03753 — REPLACE: FURNACE (IN CLOSET), REPLACE EVAP COOLER ON ROOF WITH COMBO UNIT (SFR)
  • Water heaterNot in this windowNothing in the permit records we read for this parcel that names this system. Water heaters are frequently swapped without a permit, so this line is especially weak evidence either way.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system.
  • Plumbing work on recordNot in this windowNothing in the permit records we read for this parcel that names this system. Unremarkable — plenty of buildings never need a permitted plumbing repair.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Federal Pacific Stab-Lok and Zinsco/Sylvania panels were still being installed into the 1980s. Both have documented failure-to-trip histories, by different routes: Stab-Lok breakers fail internally — the trip mechanism jams or sits out of calibration — while Zinsco breakers can weld to the bus, so the handle moves but the circuit stays live. Neither is fixed by a replacement breaker, which is why the panel is what gets replaced. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    100–150 A was typical. Workable for the original house, tight once you add EV charging or electric heat. The permit record does not confirm this; an on-site inspection is required.

Most recent permit on record for this parcel: 2026-03-19 (TR-ROW-0326-00325) — 1-40 YRD ROLL OFF TO BE DELIVERED ON 04/17 AND REMOVED ON 4/20/ WILL BE PLACED ON THE WEST SIDE OF STREET.

Permit history (14)

Permit history for this parcel — 8 of 14 records
DateRecordWhatStatusValue
2026-03-19finaledTR-ROW-0326-00325City permit recordRight-of-Way (ROW)1-40 YRD ROLL OFF TO BE DELIVERED ON 04/17 AND REMOVED ON 4/20/ WILL BE PLACED ON THE WEST SIDE OF STREETComplete
2025-09-22finaledTR-ROW-0925-01156City permit recordRight-of-Way (ROW)1-40 YRD ROLL OFF TO BE DELIVERED ON 10/17 AND REMOVED ON 10/20 /WILL BE PLACED ON THE WEST SIDE OF STREETComplete
2025-03-27finaledTR-ROW-0325-00410City permit recordRight-of-Way (ROW)40 YRD ROLL OFF TO BE DELIVERED ON 04/18 AND REMOVED ON 04/21 WEST SIDE OF STREETComplete
2024-09-24finaledTR-ROW-0924-01115City permit recordRight-of-Way (ROW)40 YRD ROLL OFF TO BE DELIVERED ON 10/18 REMOVED ON 10/22 / PLACED ON WEST SIDE OF STREETComplete
2024-04-24finaledTR-ROW-0424-00477City permit recordRight-of-Way (ROW)40 YRD ROLL OFF TO BE DELIVERED ON 04/26 REMOVED ON 4/30 WILL BE PLACED ON THE WEST SIDE OF STREETComplete
2023-10-02finaledTR-ROW-1023-01212City permit recordRight-of-Way (ROW)MILES NA SPOT ONE 40YD OT ROFF AT 303 S SANTA RITA AVE ON WEST SIDE OF SANTA RITAComplete
2023-04-17finaledTR-ROW-0423-00640City permit recordRight-of-Way (ROW)MILES NA SPOT ONE 40YD OT ROFF AT 303 S SANTA RITA AVE IN GRASSY AREA ON WEST SIDE OF SANTA RITA AVEComplete
2022-04-28finaledT22RW01685City permit recordROWMILES NA SPOT ONE 40 YD OT ROFF AT 303 S SANTA RITA AVE GRASSY AREA ON WEST SIDE OF SANTA RITA. ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. 1) Roll-offs or dumpsters shall be located in areas that are not within a drainageway, storm runoff flow line, or obstructing stormdrain infrastructure. 2) Roll-offs or dumpsters shall keep lids on so that roll-off or dumpster is kept covered when not in use. Plugs shall be kept in place. 3) Roll-offs or dumpsters that have openings at sides shall have sealed side door flaps that are kept closed so that waste liquids do not leave container. 4) Damaged containers shall be reported for replacement.Final
Show 6 older records
Permit history for this parcel — remaining 6 records
DateRecordWhatStatusValue
2021-10-14finaledT21RW04690City permit recordROWPLACEMENT OF 40 YD ROLL-OFF FOR NEIGHBORHOOD CLEAN UP AT POSTED ADDRESS. ON WEST SIDE OF STREET FOR MILES NEIGHBORHOOD ASSOCIATION. ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING.Final
2021-04-22finaledT21RW01907City permit recordROW40 YARD ROLL-OFF FOR NEIGHBORHOOD CLEAN-UP, MILES NEIGHBORHOOD ASSOCIATION.Final
2020-11-04finaledT20RW06009City permit recordROW40YD ROLLOFF FOR NEIGHBORHOOD CLEANUP MILES NEIGHBORHOOD ASSOC AT 303 S SANTA RITA AVFinal
2020-03-10finaledT20RW01564City permit recordROW40YD ROLLOFF FOR NEIGHBORHOOD CLEANUP MILES NAFinal
2008-11-21finaledT08CM03753City permit recordCOMBOREPLACE: FURNACE (IN CLOSET), REPLACE EVAP COOLER ON ROOF WITH COMBO UNIT (SFR)Final
2007-02-06finaledT07PL00275City permit recordPLUMBRE-PIPE:GAS LINEFinal

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (2)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 2 of 2 records
DateRecordWhatStatus
2019-05-09T19DV03790Code enforcement caseVegetationReferred
2019-01-23T19DV00378Code enforcement caseVegetationNoverify

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this home?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 124121740 — 14 permits on file from 2007 to 2026 (7 right-of-way (row), 5 row, 1 combo, 1 plumb) and 2 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.