Electrical permit history — 306 N Cherry Av
306 N Cherry Av, Tucson — built 1947, with 11 permits on record. Review electrical, HVAC and remodel history with links to official records.
Home
306 N Cherry Av
Built 1947 — pre-1950 knob-and-tube era · last permitted panel/service work 2021 (finaled)
Permanent link: Electrical permit history for 306 N Cherry Av (aztucsonelectricalsolutions.com/property/124032360/306-n-cherry-av-tucson-az-85719) · Public records last checked 2026-08-17
- Parcel
- 124032360
- Built
- 1947 (county record)
- Jurisdiction
- Tucson
- Zoning
- NR-2
- Assessor use
- Triplex - 1 Story
- Parcel size
- 0.22 acres
- Sewer
- Connection on file (1947) (county sewer connection records)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Rincon Heights Historic District — National Register district — Contributing (City of Tucson)
- Typical original service for a 1947 home
- approximately 30–60 A
- Service on record
- City records show the 2021 permit was finalized; the permit description states “electrical panel upgrade” — an increase in capacity as described, not a confirmed installed rating.
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & panelCurrentLast permitted 2021 (5 years ago). City inspection record: ELECTRIC - FINAL approved 2021-08-19. Contractor of record: Rimline Electric. The permit describes an increase in capacity, which is the single best sign the electrical has actually been brought forward. T21CM05170 — electrical panel upgrade
- Heating & coolingNot in this windowNothing in the permit records we read for this parcel that names this system. Cooling equipment works harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes.
- Water heaterNot in this windowNothing in the permit records we read for this parcel that names this system. Water heaters are frequently swapped without a permit, so this line is especially weak evidence either way.
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system.
- Plumbing work on recordOn recordLast permitted 2019 (7 years ago). Plumbing permits cover everything from a full re-pipe to a few feet of sewer repair, so this is a record that work happened rather than a statement about the whole system. T19CM08688 — SEWER/WATER REPLACEMENT
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check — high priority
Knob-and-tube wiring may still be present in original, un-remodeled areas. It has no ground and is not rated for modern loads or insulation contact. The permit record does not confirm this; an on-site inspection is required.
- Era-based check — high priority
Original services this age were 30–60 A fuse panels. Nearly every one still in place is undersized for a modern household. The permit record does not confirm this; an on-site inspection is required.
- Era-based check — high priority
Branch circuits from this era are typically ungrounded two-wire — the reason you see two-prong outlets or ungrounded three-prong replacements. The permit record does not confirm this; an on-site inspection is required.
- Worth confirming
There is an electrical reconnect permit from 2007. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.
Most recent permit on record for this parcel: 2026-06-25 (SD-0626-00099) — Conversion of an existing detached garage structure into one new dwelling unit, increasing the site from three dwelling units to four dwelling units. Project is submitted under the City of Tucson Residential Middle Housing development standards. Existing structure to be renovated and converted to residential occupancy with new kitchen, bathroom, plumbing, electrical, mechanical, and utility connections. Concurrent DDO and NPZ reviews are being processed..
Permit history (11)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2026-06-25 | SD-0626-00099Design review | Neighborhood Preservation Zone (NPZ)Conversion of an existing detached garage structure into one new dwelling unit, increasing the site from three dwelling units to four dwelling units. Project is submitted under the City of Tucson Residential Middle Housing development standards. Existing structure to be renovated and converted to residential occupancy with new kitchen, bathroom, plumbing, electrical, mechanical, and utility connections. Concurrent DDO and NPZ reviews are being processed. | Needs Resubmittal | |
| 2026-06-05 | TC-RES-0626-03013City permit record | New constructionConversion of an existing detached garage structure into one new dwelling unit, increasing the site from three dwelling units to four dwelling units. Project is submitted under the City of Tucson Residential Middle Housing development standards. Existing structure to be renovated and converted to residential occupancy with new kitchen, bathroom, plumbing, electrical, mechanical, and utility connections. Concurrent DDO and NPZ reviews are being processed. | Needs resubmittal | |
| 2026-03-19 | TC-COM-0326-00391City permit record | Addition / alteration*Withdrawn, per applicant and reviewer, ok per Juan G. // 2-bedroom unit addition to existing triplex | Withdrawn | |
| 2021-06-22finaled | T21CM05170City permit record | COMBOelectrical panel upgrade | Final | |
| 2021-06-21finaled | T21CM05132City permit record | COMBOelectrical panel upgrade | Final | |
| 2021-05-06finaled | T21CM03862City permit record | COMBOelectrical panels to be upgraded | Final | |
| 2019-11-22finaled | T19CM08688City permit record | COMBOSEWER/WATER REPLACEMENT | Final | |
| 2013-08-13finaled | T13CM04978City permit record | COMBOREPLACE GAS LINE - RES | Final |
Show 3 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2013-08-13finaled | T13CM04979City permit record | COMBOREPLACE GAS LINE - RES | Final | |
| 2007-10-09 | T07AN00828City permit record | ADDRNEW | Issued | |
| 2007-10-05finaled | T07EL01803City permit record | Electrical reconnectELECTRICAL RECONNECT | Final |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (6)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2024-04-04 | CE-VIO0424-01240Code enforcement case | Code enforcement case | Closed - unfounded |
| 2014-08-11 | T14DV05987Code enforcement case | Code enforcement case | Complian |
| 2014-08-11 | T14DV05988Code enforcement case | Code enforcement case | Referred |
| 2014-08-11 | T14DV05989Code enforcement case | Code enforcement case | Referred |
| 2007-07-31 | T07DV07062Code enforcement case | Refuse | Invalid |
| 2007-01-25 | T07DV00825Code enforcement case | Vegetation | Complian |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Planning work at this home?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, sent once. No list.One email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list.
How this report was built
This is a reading of public records for parcel 124032360 — 11 permits on file from 2007 to 2026 (6 combo, 1 neighborhood preservation zone (npz), 1 new construction, 1 addition / alteration) and 6 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.