Electrical permit history — 917 E Seneca St
917 E Seneca St, Tucson — built 1951, with 28 permits on record. Review electrical, HVAC and remodel history with links to official records.
Home
917 E Seneca St
Built 1951 — post-war 60–100 A service era · 28 permits on record; no permitted panel/service or HVAC work among them
Permanent link: Electrical permit history for 917 E Seneca St (aztucsonelectricalsolutions.com/property/123130680/917-e-seneca-st-tucson-az-85719) · Public records last checked 2026-08-18
- Parcel
- 123130680
- Built
- 1951 (county record)
- Jurisdiction
- Tucson
- Zoning
- NR-1
- Assessor use
- Sfr Grade 010-3 Urban Subdivided
- Parcel size
- 0.21 acres
- Living area
- 1,205 sq ft (assessor record)
- Cooling
- Evaporative (assessor record)
- Heating
- Forced Air (assessor record)
- Roof
- Asphalt (assessor record)
- Garage
- Carport (1-car) (assessor record)
- Sewer
- Connection on file (1995) (county sewer connection records)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Jefferson Park Historic District — National Register district (City of Tucson)
- Typical original service for a 1951 home
- approximately 60–100 A
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & panelNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2022 row permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not tell you the service is original — only that nothing has been permitted here recently. The build year is the better clue, and it is above.
- Heating & coolingNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2022 row permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. The assessor records cooling as Evaporative and heating as Forced Air. Cooling equipment works harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes.
- Water heaterNot in this windowNothing in the permit records we read for this parcel that names this system. Water heaters are frequently swapped without a permit, so this line is especially weak evidence either way.
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. The assessor records the roof as Asphalt.
- Plumbing work on recordNot in this windowNothing in the permit records we read for this parcel that names this system. Unremarkable — plenty of buildings never need a permitted plumbing repair.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check — high priority
60–100 A was standard. That is enough for a mid-century house, not for a modern kitchen, HVAC, and an EV. The permit record does not confirm this; an on-site inspection is required.
- Era-based check — high priority
Federal Pacific (Stab-Lok) and Zinsco/Sylvania panels were sold through this period. Stab-Lok breakers have a documented history of failing to trip internally; Zinsco breakers can weld to the bus so the handle moves without breaking the circuit. In both cases a replacement breaker does not resolve it — the panel itself is what gets replaced. The permit record does not confirm this; an on-site inspection is required.
- Era-based check
Grounded branch circuits did not become the norm until the early 1960s — much of the original wiring here is likely ungrounded. The permit record does not confirm this; an on-site inspection is required.
- Era-based check
Cloth-jacketed NM cable is common in this era. The jacket embrittles with age and heat, particularly in Tucson attics. The permit record does not confirm this; an on-site inspection is required.
Most recent permit on record for this parcel: 2026-04-24 (TR-ROW-0426-00487) — 1-40 yrd roll off to be delivered on 05/28 and removed on 06/01. Will be placed off the street.
Permit history (28)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2026-04-24finaled | TR-ROW-0426-00487City permit record | Right-of-Way (ROW)1-40 yrd roll off to be delivered on 05/28 and removed on 06/01. Will be placed off the street | Complete | |
| 2026-02-25finaled | TR-ROW-0226-00228City permit record | Right-of-Way (ROW)1-40 YRD ROLL OFF TO BE DELIVERED ON 03/26 AND REMOVED ON 03/30 | Complete | |
| 2025-09-25finaled | TR-ROW-0925-01188City permit record | Right-of-Way (ROW)1-40 YRD ROLL OFF TO BE DELIVERED ON 10/23 AND REMOVED ON 10/27 /WILL BE PLACED OFF STREET | Complete | |
| 2025-07-22finaled | TR-ROW-0725-00932City permit record | Right-of-Way (ROW)1-40 YRD ROLL OFF /WILL BE DELIVERED ON 07/31/2025 AND REMOVED ON 08/04/2025/OFF STREET | Complete | |
| 2025-05-05finaled | TR-ROW-0525-00603City permit record | Right-of-Way (ROW)40 YRD ROLL OFF TO BE DELIVERED ON 05/15/2025 AND REMOVEDO N 05/19/2025 | Complete | |
| 2025-02-24finaled | TR-ROW-0225-00256City permit record | Right-of-Way (ROW)1 40yrd roll off to be delivered on 03/27 and removed on 03/31 will be placed off the street | Complete | |
| 2024-09-25finaled | TR-ROW-0924-01124City permit record | Right-of-Way (ROW)40 YRD ROLL OFF TO BE DELIVERED ON 10/24 AND REMOVED ON 10/28 /WILL BE PLACED OFF STREET | Complete | |
| 2024-05-27finaled | TR-ROW-0524-00631City permit record | Right-of-Way (ROW)40YRD ROLL OFF WILL BE DELIVERED ON 7/25 AND REMOVED ON 7/29 WILL BE PLACED OFF STREET | Complete |
Show 20 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2024-04-30finaled | TR-ROW-0424-00501City permit record | Right-of-Way (ROW)40 YRD TO BE DELIVERED ON 5/02/2024 REMOVED ON 5/06 /WILL BE LOCATED ON THE SOUTHSIDE OF STREET ACROSS FROM THIS ADDRESS EAST OF TYNDALL | Complete | |
| 2024-03-18finaled | TR-ROW-0324-00309City permit record | Right-of-Way (ROW)40 YRD ROLL OFF TO BE DELIVERED ON 03/21 AND REMOVED 3/25 | Complete | |
| 2023-10-16finaled | TR-ROW-1023-01263City permit record | Right-of-Way (ROW)JEFFERSON PARK NA SPOT ONE 40YD OT ROFF AT 917 E SENECA ST SOUTH SIDE OF STREET ACROSS FROM THIS ADDRESS EAST OF TYNDALL | Complete | |
| 2023-07-17finaled | TR-ROW-0723-00955City permit record | Right-of-Way (ROW)JEFFERSON PARK NA SPOT ONE 40YD OT ROFF AT 917 E SENECA ST ON SOUTH SIDE OF STREET ACROSS FROM THIS ADDRESS EAST OF TYNDALL | Complete | |
| 2023-05-08finaled | TR-ROW-0523-00715City permit record | Right-of-Way (ROW)JEFFERSON PARK NA SPOT ONE 40YD OT ROFF AT 917 E SENECA ST ON SOUTH SIDE OF STREET ACROSS FROM THIS ADDRESS EAST OF TYNDALL | Complete | |
| 2023-03-07finaled | TR-ROW-0323-00467City permit record | Right-of-Way (ROW)JEFFERSON PARK NA SPOT ONE 40YD OT ROFF AT 917 E SENECA ST ON SOUTH SIDE OF STREET ACROSS FROM THIS ADDRESS EAST OF TYNDALL | Complete | |
| 2022-10-18finaled | T22RW03784City permit record | Right-of-Way (ROW)SPOT (1) 40 YD ROLL-OFF ACROSS THE STREET FROM POSTED ADDRESS/EAST OF TYNDALL AV FOR THE JEFERSON PA; Work Order: WF6963785 | Complete | |
| 2022-05-18finaled | T22RW01900City permit record | ROWPLACEMENT OF A 40 YARD ROLL-OFF FOR JEFFERSON PARK NEIGHBORHOOD ASSOCIATION CLEAN-UP. PLACEMENT WILL BE ACROSS THE STREET OF POSTED ADDRESS. 1) Roll-offs or dumpsters shall be located in areas that are not within a drainageway, storm runoff flow line, or obstructing stormdrain infrastructure. 2) Roll-offs or dumpsters shall keep lids on so that roll-off or dumpster is kept covered when not in use. Plugs shall be kept in place. 3) Roll-offs or dumpsters that have openings at sides shall have sealed side door flaps that are kept closed so that waste liquids do not leave container. 4) Damaged containers shall be reported for replacement. | Final | |
| 2022-03-15finaled | T22RW00944City permit record | ROWPLACEMENT OF 40-YD ROLL-OFF ACROSS THE STREET OF POSTED ADDRESS FOR JEFFERSON PARK NEIGHBORHOOD ASSOCIATION. ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. 1) Roll-offs or dumpsters shall be located in areas that are not within a drainageway, storm runoff flow line, or obstructing stormdrain infrastructure. 2) Roll-offs or dumpsters shall keep lids on so that roll-off or dumpster is kept covered when not in use. Plugs shall be kept in place. 3) Roll-offs or dumpsters that have openings at sides shall have sealed side door flaps that are kept closed so that waste liquids do not leave container. 4) Damaged containers shall be reported for replacement. | Final | |
| 2021-12-16finaled | T21RW05296City permit record | ROWJEFFERSON PARK NA SPOT (1) 40YD OT ROFF AT 917 E SENECA ST SOUTHSIDE OF STREET EAST OF TYNDALL | Final | |
| 2021-09-29finaled | T21RW04466City permit record | ROWPLACEMENT OF A 40 YARD ROLL-OFF FOR JEFFERSON PARK NEIGHBORHOOD ASSOCIATON CLEAN UP. LOCATION OF ROLL-OFF IS ACROSS THE STREET FROM POSTED ADDRESS. ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. OTHER ACTIVITIES IN THE AREA, WILL NEED TO COORDINATE TRAFFIC CONTROL SETUP WITH EXISTING SETUP. | Final | |
| 2020-10-23finaled | T20RW05807City permit record | ROW40 YARD ROLL-OFF IN FRONT OF POSTED ADDRESS FOR JEFFERSON PARK NEIGHBORHOOD. | Final | |
| 2019-08-07finaled | T19RW04344City permit record | ROW40 YD ROLLOFF FOR NEIGHBORHOOD CLEANUP-JEFFERSON PARK NA PROPER BARRICADING REQUIRED, SEE ATTACHED MEMO | Final | |
| 2019-05-08finaled | T19RW02574City permit record | ROW40 YD ROLLOFF FOR NEIGHBORHOOD CLEANUP-JEFFERSON PARK NA | Final | |
| 2019-03-26finaled | T19EL00090City permit record | ELECTUpgrade existing system from 60A to 200A Overhead. (VH ) | Final | |
| 2019-01-25finaled | T19RW00400City permit record | ROW40 YD ROLLOFF FOR NEIGHBORHOOD CLEANUP-JEFFERSON PARK NA | Final | |
| 2018-10-05finaled | T18RW04492City permit record | ROW40 YD ROLLOFF FOR NEIGHBORHOOD CLEANUP-JEFFERSON PARK NA | Final | |
| 2018-05-02finaled | T18RW01986City permit record | ROW40YD ROLLOFF FOR NEIGHBORHOOD CLEANUP - JEFFERSON PARK NA | Final | |
| 2018-01-10finaled | T18RW00192City permit record | ROW40 YD ROLLOFF FOR NEIGHBORHOOD CLEANUP-JEFFERSON PARK NA | Final | |
| 2017-09-25finaled | T17RW04218City permit record | ROW40 YARD ROLL-OFF SPOTTED IN STREET JUST EAST OF SENECA/TYNDALL INTERSECTION | Final |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (3)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2022-02-10 | T22DV01116Code enforcement case | Code enforcement case | Complian |
| 2021-05-04 | T21DV02615Code enforcement case | Refuse | Complian |
| 2016-07-18 | T16DV04371Code enforcement case | Refuse | Complian |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.
In the public record: All homes in 85719 · Homes by ZIP code · Commercial property in 85719 · Permit data by neighborhood
Planning work at this home?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, sent once. No list.One email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list.
How this report was built
This is a reading of public records for parcel 123130680 — 28 permits on file from 2017 to 2026 (15 right-of-way (row), 12 row, 1 elect) and 3 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-18; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.