Electrical permit history — 2720 E Seneca St

2720 E Seneca St, Tucson — built 1946, with 5 permits on record. Review electrical, HVAC and remodel history with links to official records.

Home

2720 E Seneca St

Built 1946 — pre-1950 knob-and-tube era · last permitted panel/service work 2021 (finaled)

Parcel
123023220
Built
1946 (county record)
Jurisdiction
Tucson
Zoning
R-1
Assessor use
Sfr Grade 010-3 Urban Subdivided
Parcel size
0.24 acres
Living area
896 sq ft (assessor record)
Cooling
Evaporative (assessor record)
Heating
Wall Furnace (assessor record)
Roof
Asphalt (assessor record)
Garage
Garage (2-car) (assessor record)
Sewer
Connection on file (1954, 2006) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Blenman-Elm Historic District — National Register district (City of Tucson)
Typical original service for a 1946 home
approximately 30–60 A
Service on record
City records show the 2021 permit was finalized; the permit description states “Upgrade electrical service to 200 amps” — an increase in capacity as described, not a confirmed installed rating.

See the property

County aerial photograph centered on 2720 E Seneca St, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & panelCurrentLast permitted 2021 (5 years ago). City inspection record: ELECTRIC - FINAL approved 2021-10-18. The permit describes an increase in capacity, which is the single best sign the electrical has actually been brought forward. T21CM05496 — Upgrade electrical service to 200 amps
  • Heating & coolingNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 1997 addition / alteration permit is on file — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. The assessor records cooling as Evaporative and heating as Wall Furnace. Cooling equipment works harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes.
  • Water heaterPermitted — completion not confirmedA 2023 permit specifies this work (the permit description states “40 gallon gas water heater replacement, like for like”), but the available record does not show a final inspection. The work was permitted, but final completion is not confirmed. Official status: Issued. TC-RES-0323-03502 — 40 gallon gas water heater replacement, like for like
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. The assessor records the roof as Asphalt.
  • Plumbing work on recordNot in this windowNothing in the permit records we read for this parcel that names this system. Unremarkable — plenty of buildings never need a permitted plumbing repair.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Knob-and-tube wiring may still be present in original, un-remodeled areas. It has no ground and is not rated for modern loads or insulation contact. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check — high priority

    Original services this age were 30–60 A fuse panels. Nearly every one still in place is undersized for a modern household. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check — high priority

    Branch circuits from this era are typically ungrounded two-wire — the reason you see two-prong outlets or ungrounded three-prong replacements. The permit record does not confirm this; an on-site inspection is required.

Most recent permit on record for this parcel: 2023-03-10 (TC-RES-0323-03502) — 40 gallon gas water heater replacement, like for like.

Permit history (5)

Permit history for this parcel — 5 of 5 records
DateRecordWhatStatusValue
2023-03-10expired 2023-09-18TC-RES-0323-03502City permit recordResidential Building - One or Two Family40 gallon gas water heater replacement, like for likeIssued
2021-07-06finaledT21CM05496City permit recordCOMBOUpgrade electrical service to 200 ampsFinal
1998-03-11expired 1998-09-13T98BU00619City permit recordFence / wallWALL:Expired
1997-04-14finaledT97CM00840City permit recordAddition / alterationADDITION:GARAGE & DINING ROOMFinal
1997-04-14finaledT97EL00367City permit recordELECTELECTRIC SERVICE; ADDING METER # 2Final

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this home?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 123023220 — 5 permits on file from 1997 to 2023 (1 residential building - one or two family, 1 combo, 1 fence / wall, 1 addition / alteration) — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.