3845 E Lee St

Built 1975 — FPE/Zinsco panel era · last permitted panel/service work 1999 (finaled) · HVAC 2002 (finaled)

Parcel
12218026B
Built
1975 (county record)
Jurisdiction
Tucson
Zoning
R-2
Assessor use
Triplex - 2 Story
Parcel size
0.15 acres
Living area
3,375 sq ft (assessor record)
Sewer
Connection on file (1975) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)
Typical original service for a 1975 home
approximately 100–150 A
Service on record
City records show the 1999 permit was finalized; the permit description states “UPGRADE:ELECTRIC 60 AMP TO 100 AMP” — an increase in capacity as described, not a confirmed installed rating.

See the property

County aerial photograph centered on 3845 E Lee St, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & panelCurrentLast permitted 1999 (27 years ago). Contractor of record: ELECTRICAL EXCELLENCE INC. The permit describes an increase in capacity, which is the single best sign the electrical has actually been brought forward. T99EL00238 — UPGRADE:ELECTRIC 60 AMP TO 100 AMP
  • Heating & coolingLikely dueLast permitted 2002 (24 years ago). City inspection record: MECHANICAL - FINAL approved 2002-08-27. Contractor of record: MARTIN S HEATING AND COOLING INC. Cooling equipment works harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Equipment from before about 2010 generally runs R-22, which has not been produced since 2020 — repairs mean reclaimed refrigerant at a price that often exceeds replacing the unit. T02ME00575 — REPLACE: FURNACE (APA)
  • Water heaterGetting onLast permitted 2017 (9 years ago). T17PL00122 — replace 40 gallon gas water heater
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system.
  • Plumbing work on recordNot in this windowNothing in the permit records we read for this parcel that names this system. Unremarkable — plenty of buildings never need a permitted plumbing repair.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Federal Pacific Stab-Lok and Zinsco/Sylvania panels were still being installed into the 1980s. Both have documented failure-to-trip histories, by different routes: Stab-Lok breakers fail internally — the trip mechanism jams or sits out of calibration — while Zinsco breakers can weld to the bus, so the handle moves but the circuit stays live. Neither is fixed by a replacement breaker, which is why the panel is what gets replaced. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    100–150 A was typical. Workable for the original house, tight once you add EV charging or electric heat. The permit record does not confirm this; an on-site inspection is required.

Most recent permit on record for this parcel: 2018-02-07 (T18CM00957) — FIRE DAMAMGE REPAIR AND INTERIOR REMODEL (T17DV05380 BIGMAN).

Permit history (7)

Permit history for this parcel — 7 of 7 records
DateRecordWhatStatusValue
2018-02-07expired 2018-12-04T18CM00957City permit recordCOMBOFIRE DAMAMGE REPAIR AND INTERIOR REMODEL (T17DV05380 BIGMAN)Expired
2017-10-17finaledT17PL00122City permit recordPLUMBreplace 40 gallon gas water heaterFinal
2017-09-01finaledT17PL00109City permit recordPLUMBPressure test gas line for reconnectFinal
2002-08-21finaledT02ME00575City permit recordMECHREPLACE: FURNACE (APA)Final
2002-08-21finaledT02ME00576City permit recordMECHREPLACE: FURNACE (APA)Final
2002-08-09finaledT02ME00540City permit recordMECHINSTALL: FURNACE (APA)Final
1999-02-05finaledT99EL00238City permit recordELECTUPGRADE:ELECTRIC 60 AMP TO 100 AMPFinal

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (8)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 8 of 8 records
DateRecordWhatStatus
2018-12-11T18DV08025Code enforcement caseRefuseComplian
2018-06-04T18DV03161Code enforcement caseCode enforcement caseComplian
2017-10-17T17DV05380Code enforcement caseFireComplian
2017-09-21T17DV04771Code enforcement caseCode enforcement caseComplian
2013-07-30T13DV05516Code enforcement caseRefuseComplian
2011-10-25T11DV08672Code enforcement caseCode enforcement caseNoverify
2007-10-18T07DV11245Code enforcement caseRefuseComplian
2006-12-28T06DV03293Code enforcement caseRefuseVoid

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this home?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 12218026B — 7 permits on file from 1999 to 2018 (3 mech, 2 plumb, 1 combo, 1 elect) and 8 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.