Electrical permit history — 1417 N Woodland Av

1417 N Woodland Av

  • Electrical service: no service or panel permit on record. A 1960 house likely still has its original 60 to 100 A service.
  • Watch for: built 1960, when Federal Pacific and Zinsco panels were sold. Worth a look at the panel label.
  • Other work on record: trade permit 2020, AC replaced 2009, trade permit 1997.

From City of Tucson permits and the Pima County Assessor, checked 13 Nov 2026. Not an inspection.

I am a
Get a free panel check

Is it time to upgrade?

Likely yes: no service upgrade is on record for this 1960 house.

  • Electrical service & panelLikely needs attentionNo service or panel permit on record. A 1960 house likely still has its original 60 to 100 A service. The panel makes and wiring methods of that era are what the era notes below flag, and only a look at the panel settles it.
  • Heating & coolingLikely needs attentionLast permitted 2009 (17 years ago) — the permit passed final inspection. The assessor still records cooling as Evaporative; the 2009 permit is the newer evidence (assessor characteristics can lag permitted work). Cooling equipment works harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Equipment from before about 2010 generally runs R-22, which has not been produced since 2020 — repairs mean reclaimed refrigerant at a price that often exceeds replacing the unit. T09ME00020 — Replace 3 ton split system
  • Water heaterWorth checkingNo permit on record names this system. Water heaters are frequently swapped without a permit, so this line is especially weak evidence either way.
  • RoofWorth checkingNo permit on record names this system. The assessor records the roof as Built Up.

What that usually means electrically

  • Era-based check — high priority

    60–100 A was standard. That is enough for a mid-century house, not for a modern kitchen, HVAC, and an EV.

  • Era-based check — high priority

    Federal Pacific (Stab-Lok) and Zinsco/Sylvania panels were sold through this period. Stab-Lok breakers have a documented history of failing to trip internally; Zinsco breakers can weld to the bus so the handle moves without breaking the circuit. In both cases a replacement breaker does not resolve it — the panel itself is what gets replaced.

  • Era-based check

    Grounded branch circuits did not become the norm until the early 1960s — much of the original wiring here is likely ungrounded.

  • Era-based check

    Cloth-jacketed NM cable is common in this era. The jacket embrittles with age and heat, particularly in Tucson attics.

  • Routine

    A trade permit was pulled in 2020. Trade permits cover electrical, plumbing, and mechanical work individually, so some permitted trade work has been done here since.

What to check at the panel

These are the things only someone standing at the panel can settle — about a minute’s work.

  1. The number stamped on the main breaker handle — 100, 125, 150, 175 or 200. That is the service rating, and no record on this page confirms it.
  2. The busbar rating printed on the panel label. It is a different number from the main breaker, and it is the one that decides how much solar a panel can take under the 120% rule.
  3. The manufacturer and catalog number on the label inside the door.
  4. How many full-size spaces are left, how many positions the label permits a tandem breaker in, and the tandem limit the label states. A full panel is a different job from a full service.
  5. The conductor material at the main lugs, and whether the terminations look clean and tight.
  6. Whether there is a separate meter-main outside as well as the panel indoors — that changes where a disconnect and any new feeder would land.
  7. Whether the water heater, dryer and range are gas or electric. No public record carries fuel type, and it is the single biggest variable in a load calculation — it can move the calculated load on the same house by more than 40 A.
  8. The brand on the door or the breaker faces. Federal Pacific panels usually read “Federal Pacific Electric” or “FPE”; Zinsco panels read “Zinsco”, or on later stock “Sylvania” or “Sylvania-Zinsco”. Finding a Square D, Eaton, Cutler-Hammer, Siemens or GE panel here is the ordinary result and is not a finding — those are current, supported lines with breakers on the shelf.
  9. Whether receptacles are two-prong, and whether any three-prong replacements have an actual ground behind them. A $10 tester answers this at every outlet.
  10. Whether the kitchen counter, bathroom, garage and exterior receptacles have GFCI protection, and whether the test button actually trips them.

With those in hand you can run the numbers yourself. The load calculator does the NEC 220.82 optional-method calculation — the same method a permit application uses — and shows its work. It offers to start from the 1,346 sq ft on the assessor record; every other value is yours to enter. Open the load calculator

What these jobs cost here

Estimated ranges for this property, from its age, its size and the Tucson permit fee and code.

Electrical panel or service upgrade Estimate

$5,200

Most jobs like this land between $4,500 and $6,300.

The bottom of this range is a clean, simple job: single storey, framed wall, the panel staying where it is, a short service run, and nothing unexpected once the cover comes off. That job is real and we do book it — but it is the best case, not the average, and the figure above it is what most houses actually come to.

Priced from built 1960 (post-war 60–100 A service era); City of Tucson permit fee and the 2023 NEC it has adopted.

Priced with Tucson Electric Power’s charges — TEP serves the City of Tucson. The assessor records block, brick or adobe walls, so the core drilling and patch are priced in.

What would move this price
  • Only if the panel has to move — a clothes closet, a bathroom, over a stairway, or behind a door +$3,900
  • Only if the mast is undersized or corroded — common at this age +$1,300
  • Only if the metal water and gas piping are not already bonded — usually not, at this age +$600
  • Only if the original fuse or split-bus panel is still in service +$1,700

If every one of those turned out to apply, this becomes about $13,600. That is the worst realistic case.

Before you spend anything
  • A service upgrade fixes capacity and the safety of the service equipment. It does not fix branch wiring. If the reason you are here is flickering lights, warm outlets or cloth-jacketed wiring, an upgrade is a down payment on a much bigger problem, and it is worth knowing that before you spend in the wrong order.
  • You may not need the upgrade at all. NEC 220.87 lets an existing dwelling be sized from twelve months of actual metered demand rather than a calculated load, and real houses draw far less than the calculation predicts. Ask your utility for a year of interval data and have it run that way first. Two cautions so this does not backfire: the demand tile in a TEP online account shows on-peak demand only, which is not the annual maximum the code asks for — you want the formal usage-data release — and 220.87 proves CAPACITY and nothing else. It does not create empty breaker spaces, and it does not make an obsolete panel, or one whose breakers have a documented failure history, safe. Those are separate questions with separate answers — and where the era makes a brand worth checking, the report above says so on its own.

Air conditioning or heat pump replacement Estimate

$13,300

Most jobs like this land between $10,300 and $16,800.

Priced from a 3-ton split air conditioner with gas furnace on the 2009 permit T09ME00020 (passed final inspection), so the replacement is priced like for like; the assessor’s cooling field still reads “Evaporative”, but the newer 2009 permit names refrigerated equipment; City of Tucson permit fee.

What would move this price
  • Only if the duct has to be replaced — no record carries its condition, and on an attic system at this age it is a real possibility +$6,200

If every one of those turned out to apply, this becomes about $23,000. That is the worst realistic case.

  • Because a permit names the size, this is priced at that size rather than from floor area. Worth asking whether that size was ever right: a Manual J often comes out smaller, and a correctly sized machine costs less and behaves better in the monsoon.
Before you spend anything
  • If someone quotes you “just the outside unit” on a system installed between about 2010 and 2024, stop. New condensers use R-454B or R-32; an R-410A indoor coil cannot be matched to one unless the manufacturer publishes that exact combination with a mitigation kit. The honest options are to find remaining pre-2025 R-410A stock — still legal to install, but scarce, and it still has to meet the Arizona efficiency floor — or to replace both halves as a matched system.
  • If you are told a heat pump means you need a 200 A service, ask which load. It is almost never the compressor — a 5-ton outdoor unit is about a 31 A circuit. It is the electric BACKUP HEAT STRIP, which on a large kit can be a 109 A circuit on its own. In Tucson's mild heating season the strip kit can often be sized far smaller, or left out, and the service question disappears with it.
  • Equipment here lasts ten to fourteen years, not the fifteen to twenty you will read nationally — a rooftop package unit at the short end. Replace rather than repair if the unit is twelve or more and the repair is over $1,500, if the compressor has failed and it is eight or more, or if the repair is over 40% of a new system.
What the record cannot tell us
  • Whether the service is already 200 A. Nothing in the public record says so, and the number is stamped on the main breaker handle.
  • Whether the panel can stay where it is. A panel in a closet, over stairs or behind a door has to move, and that alone adds $1,500 to $5,000.
  • Whether the service comes in overhead or underground. This is priced as overhead; an underground service with an adequate lateral is a few hundred dollars cheaper, and one with an undersized lateral is thousands more.
  • The duct. No record carries its condition, and on a Tucson house with duct in an unconditioned attic it is often worth more than a bigger machine.
  • Whether that floor area is all conditioned space. An assessor figure can include a garage, an enclosed porch or an addition that was never cooled, and every square foot of that oversizes the equipment this page priced.

Price it for your house — change the assumptions (the panel’s location, the duct, the tonnage, whether the service is overhead or underground) and watch the number move.

Solar potential

The county’s building-footprint layer maps ≈ 2,600 sq ft of roof plan area here. In Tucson a rooftop array produces about 1,645 kWh per installed kW per year (PVWatts), so a typical 6–8 kW home system fits on a fraction of that roof and makes roughly 10,000–13,000 kWh a year. TEP credits exported surplus at its RCP rate — about 5¢/kWh for new applications, locked for 10 years — so sizing to the home’s own use matters more than filling the roof. Already have panels? Check whether they were permitted and finaled.

Flood and drainage

The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.

The record behind this read

Parcel
121122480
Year constructed
1960 (county record)
Permitting authority
Tucson
Zoning
R-1
Living area
1,346 sq ft
Cooling
Evaporative (assessor record; a 2009 permit names refrigerated equipment, and this report goes by the permit)
Heating
Forced Air
Electrical service
No service or panel permit on record. A 1960 house likely still has its original 60 to 100 A service. (the era estimate is from the year built, 1960 — not a measurement)

Living area, cooling and heating come from the Pima County Assessor’s file published 28 Jan 2026. Check any row against Pima County’s own parcel record ↗.

What this means for work here

The most recent permit with evidence of issuance is dated 2020. City records show the permit was finalized. The permit covers only the work described in that record.

What that reading rests on. The issuing offices hold 3 building permits for this parcel dated between 1997 and 2020. Three trade permits. All 3 carry a final inspection. There is 1 code-enforcement case recorded against the parcel, all of them closed. We do not reproduce complaint text — it routinely names people with no connection to the property.

Street and utility work at this address. The City’s file also shows one right-of-way or utility permit here (2025) — work in the street or on a utility’s lines, not on the building, so it is left out of the counts above.

Go straight to the records

Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.

Permit records courtesy of the City of Tucson — each link opens the City’s own file. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 121122480.

See an error? Report a correction · About this data.

Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.

In the public record: All homes in 85712 · Homes by ZIP code · Commercial property in 85712 · Permit data by neighborhood

Planning work at this home?

Arizona Electrical Solutions — electrical, HVAC, underground, design-build and general contracting in Tucson (four Arizona ROC licenses). The address, parcel and this report travel with your request.

Get a free panel check

Want a plain-English brief of this record first?

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this property compares nearby

Built in 1960 — earlier than about 57% of the 8,300 homes in ZIP 85712. 1,346 sq ft of living area — close to this ZIP’s median of 1,430 sq ft. Properties on N WOODLAND AV hold 127 City permits on record, 26 of them since 2022.

Counts and years from the same public records.

How this report was built

This is a reading of public records for parcel 121122480 — 3 City permits on file from 1997 to 2020 and 1 street or utility permit and 1 code enforcement case — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive. City of Tucson permit records go back to the mid-1990s, with fewer before 2006, when the City’s older paper files were only partly digitized. The construction year, living area, cooling, heating, roof and walls on this page come from our saved copy of the Assessor’s own published data file (dated 28 Jan 2026). The sewer connection file and the flood map were not read for this snapshot. A permit that is absent here may predate the digitized record or sit in a system this snapshot did not read. This record was built 22 Aug 2026 and compared against the City’s 13 Nov 2026 permit export, with no change for this parcel.

What this report is and is not. This is a screening report written by Arizona Electrical Solutions from public records — the year the building went up, how it is classified and what has been permitted. It is not an inspection, an appraisal, a floodplain determination, or engineering, legal or purchasing advice, and nothing in it confirms what is installed at this address: a permit shows what was permitted, a missing permit does not mean nothing was done, and era notes describe what was common when the building went up, not what is in this one. Price figures are estimates, not quotes. The issuing agency’s own record is the official one and controls over anything summarized here — every permit links to it. Only someone looking at the panel can confirm the service size, the panel brand or the wiring.

Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.