Electrical permit history — 5832 E Lee St
5832 E Lee St, Tucson — built 1949, with 2 permits on record. Review electrical, HVAC and remodel history with links to official records.
Home
5832 E Lee St
Built 1949 — pre-1950 knob-and-tube era · 2 open code cases · 2 permits on record; no permitted panel/service or HVAC work among them
Permanent link: Electrical permit history for 5832 E Lee St (aztucsonelectricalsolutions.com/property/12106159b/5832-e-lee-st-tucson-az-85712) · Public records last checked 2026-08-17
- Parcel
- 12106159B
- Built
- 1949 (county record)
- Jurisdiction
- Tucson
- Zoning
- R-1
- Assessor use
- Sfr Grade 010-3 Urban Subdivided
- Parcel size
- 0.21 acres
- Living area
- 1,806 sq ft (assessor record)
- Cooling
- Refrigeration (assessor record)
- Heating
- Forced Air (assessor record)
- Roof
- Prepared Roll (assessor record)
- Pool
- Yes (assessor record)
- Sewer
- Connection on file (1963) (county sewer connection records)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
- Typical original service for a 1949 home
- approximately 30–60 A
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & panelNot in this windowNothing in the permit records we read for this parcel that names this system. That does not tell you the service is original — only that nothing has been permitted here recently. The build year is the better clue, and it is above.
- Heating & coolingNot in this windowNothing in the permit records we read for this parcel that names this system. The assessor records cooling as Refrigeration and heating as Forced Air. Cooling equipment works harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes.
- Water heaterPermitted — completion not confirmedA 2024 permit specifies this work (the permit description states “Replacing 50 Gallon Electric water heater, like for like”), but the available record does not show a final inspection. The work was permitted, but final completion is not confirmed. Official status: Issued. TC-RES-0424-02032 — Replacing 50 Gallon Electric water heater, like for like
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. The assessor records the roof as Prepared Roll.
- Plumbing work on recordNot in this windowNothing in the permit records we read for this parcel that names this system. Unremarkable — plenty of buildings never need a permitted plumbing repair.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check — high priority
Knob-and-tube wiring may still be present in original, un-remodeled areas. It has no ground and is not rated for modern loads or insulation contact. The permit record does not confirm this; an on-site inspection is required.
- Era-based check — high priority
Original services this age were 30–60 A fuse panels. Nearly every one still in place is undersized for a modern household. The permit record does not confirm this; an on-site inspection is required.
- Era-based check — high priority
Branch circuits from this era are typically ungrounded two-wire — the reason you see two-prong outlets or ungrounded three-prong replacements. The permit record does not confirm this; an on-site inspection is required.
- Worth looking at
There are 2 open code enforcement cases on this parcel. An open case can hold up a permit, and if it touches unpermitted work the electrical scope usually has to be brought up to code as part of resolving it.
- Worth confirming
The assessor records a pool on this parcel. Equipment bonding, the equipotential bonding grid and GFCI protection on the pump and light circuits are the usual findings on pool equipment — the pool-bonding rules in NEC Article 680 were expanded in the 2008 cycle, so a pool built before that is worth an on-site check.
Most recent permit on record for this parcel: 2024-04-05 (TC-RES-0424-02032) — Replacing 50 Gallon Electric water heater, like for like.
Permit history (2)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2024-04-05expired 2024-10-13 | TC-RES-0424-02032City permit record | Residential Building - One or Two FamilyReplacing 50 Gallon Electric water heater, like for like | Issued | |
| 2011-12-13finaled | T11CM03815City permit record | COMBOREPLACE: GROUND MOUNT SPLIT SYSTEM - RES (APA) | Final |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (5)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2026-01-06 | CE-VIO0126-00075Code enforcement case | Fire | Active |
| 2025-05-22 | CE-VIO0525-02255Code enforcement case | Code enforcement case | Citation |
| 2015-07-02 | T15DV04827Code enforcement case | Refuse | Complian |
| 2013-03-21 | T13DV01756Code enforcement case | Code enforcement case | Complian |
| 2003-02-06 | T03VL00169Code enforcement case | Code enforcement case | Closed |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Planning work at this home?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, sent once. No list.One email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list.
How this report was built
This is a reading of public records for parcel 12106159B — 2 permits on file from 2011 to 2024 (1 residential building - one or two family, 1 combo) and 5 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.