Built 1960 — post-war 60–100 A service era · last permitted panel/service work 2008 (finaled) · HVAC 2008 (permit expired without a confirmed final)

Parcel
120051310
Built
1960 (county record)
Jurisdiction
Tucson
Zoning
R-2
Assessor use
Sfr Grade 010-2 Urban Subdivided
Parcel size
0.18 acres
Living area
932 sq ft (assessor record)
Cooling
Refrigeration (assessor record)
Heating
Forced Air (assessor record)
Roof
Built Up (assessor record)
Garage
Carport (1-car) (assessor record)
Sewer
Connection on file (1960) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)
Typical original service for a 1960 home
approximately 60–100 A
Service on record
City records show the 2008 permit was finalized; the permit description states “UPGRADE: ELECTRICAL TO 200 AMP” — an increase in capacity as described, not a confirmed installed rating.

See the property

County aerial photograph centered on 860 W Missouri St, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & panelCurrentLast permitted 2008 (18 years ago). City inspection record: last recorded inspection 2008-06-26; no approved final is shown. Contractor of record: JC CONSTRUCTION INC. The permit describes an increase in capacity, which is the single best sign the electrical has actually been brought forward. T08EL01167 — UPGRADE: ELECTRICAL TO 200 AMP
  • Heating & coolingPermitted — completion not confirmedA 2008 permit specifies this work (the permit description states “REPLACE: A/C UNIT”), but the available record does not show a final inspection. The permit expired without a confirmed final status. Official status: Expired. Contractor of record: J C CONTRACTORS ,. The assessor records cooling as Refrigeration and heating as Forced Air. T08ME00612 — REPLACE: A/C UNIT
  • Water heaterNot in this windowNothing in the permit records we read for this parcel that names this system. Water heaters are frequently swapped without a permit, so this line is especially weak evidence either way.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. The assessor records the roof as Built Up.
  • Plumbing work on recordNot in this windowNothing in the permit records we read for this parcel that names this system. Unremarkable — plenty of buildings never need a permitted plumbing repair.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    60–100 A was standard. That is enough for a mid-century house, not for a modern kitchen, HVAC, and an EV. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check — high priority

    Federal Pacific (Stab-Lok) and Zinsco/Sylvania panels were sold through this period. Stab-Lok breakers have a documented history of failing to trip internally; Zinsco breakers can weld to the bus so the handle moves without breaking the circuit. In both cases a replacement breaker does not resolve it — the panel itself is what gets replaced. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    Grounded branch circuits did not become the norm until the early 1960s — much of the original wiring here is likely ungrounded. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    Cloth-jacketed NM cable is common in this era. The jacket embrittles with age and heat, particularly in Tucson attics. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    Solar was permitted here in 2025. That means there is an existing interconnection, and the main breaker and busbar rating already carry a PV backfeed — so anything else you add (an EV charger, a heat pump) has to be checked against what is left under the 120% rule, not against the service size alone.

Most recent permit on record for this parcel: 2025-07-09 (TC-SOL-0725-00935) — Installation of 7.79 kW PV System.

Permit history (5)

Permit history for this parcel — 5 of 5 records
DateRecordWhatStatusValue
2025-07-09finaledTC-SOL-0725-00935City permit recordSolar PVInstallation of 7.79 kW PV SystemComplete
2022-12-12TC-RES-1222-01464City permit recordResidential Building - One or Two FamilyEnclose Garage for StorageExpired
2021-10-13finaledT21RW04652City permit recordROWW/O # 4335814- RELOCATE GAS METER (2) 5X5 BELLHOLES IN DIRT ALLEY. COYL EXPEDITED PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. ALLEY MUST BE RESTORED TO EXISTING OR BETTER CONDITION. ALLEY SURFACE MUST BE GRADED AND COMPACTED TO CITY STANDARDS AND SPECIFICATIONS FOR PUBLIC IMPROVEMENTS AND EXISTING DRAINAGE PATTERNS MUST BE RESTORED AND MAINTAINED. ANY DISTURBED GRAVEL MUST BE REPLACED.Final
2008-10-06expired 2009-04-04T08ME00612City permit recordMECHREPLACE: A/C UNITExpired
2008-06-25finaledT08EL01167City permit recordELECTUPGRADE: ELECTRICAL TO 200 AMPFinal

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this home?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 120051310 — 5 permits on file from 2008 to 2025 (1 solar pv, 1 residential building - one or two family, 1 row, 1 mech) — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.