Electrical permit history — 370 N Main Av
370 N Main Av, Tucson — built 1991, with 12 permits on record. Review electrical, HVAC and remodel history with links to official records.
Home
370 N Main Av
Built 1991 — pre-1996 GFCI-code era · last permitted panel/service work 2025 (finaled)
Permanent link: Electrical permit history for 370 N Main Av (aztucsonelectricalsolutions.com/property/11710152a/370-n-main-av-tucson-az-85701) · Public records last checked 2026-08-17
- Parcel
- 11710152A
- Built
- 1991 (assessor record — effective construction year, which can move after a major remodel)
- Jurisdiction
- Tucson
- Zoning
- HR-2
- Assessor use
- Sfr Grade 010-4 Urban Subdivided
- Parcel size
- 0.35 acres
- Living area
- 2,106 sq ft (assessor record)
- Cooling
- Evaporative (assessor record)
- Heating
- Forced Air (assessor record)
- Roof
- Built Up (assessor record)
- Sewer
- Connection on file (1991) (county sewer connection records)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- El Presidio Historic District — Historic Preservation Zone (City of Tucson)
- Typical original service for a 1991 home
- approximately 150–200 A
- Service on record
- City records show the 2025 permit was finalized; the permit description states “upgrade from 100 to 200 amp service” — an increase in capacity as described, not a confirmed installed rating.
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & panelCurrentLast permitted 2025 (1 year ago). City inspection record: COT - RSEL - Electrical Final approved 2025-05-23. The permit describes an increase in capacity, which is the single best sign the electrical has actually been brought forward. TC-RES-0425-02141 — upgrade from 100 to 200 amp service
- Heating & coolingNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 historic preservation zone/historic landmark permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. The assessor records cooling as Evaporative and heating as Forced Air. Cooling equipment works harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes.
- Water heaterNot in this windowNothing in the permit records we read for this parcel that names this system. Water heaters are frequently swapped without a permit, so this line is especially weak evidence either way.
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. The assessor records the roof as Built Up.
- Plumbing work on recordNot in this windowNothing in the permit records we read for this parcel that names this system. Unremarkable — plenty of buildings never need a permitted plumbing repair.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check
GFCI protection was not required at all kitchen counter receptacles until the 1996 code. Expect gaps in kitchens, garages, and exterior outlets. The permit record does not confirm this; an on-site inspection is required.
- Worth confirming
Solar was permitted here in 2025. That means there is an existing interconnection, and the main breaker and busbar rating already carry a PV backfeed — so anything else you add (an EV charger, a heat pump) has to be checked against what is left under the 120% rule, not against the service size alone.
- Era-based check
Panels and breakers from this era are near the end of their service life even where the original installation was sound. The permit record does not confirm this; an on-site inspection is required.
Most recent permit on record for this parcel: 2026-03-23 (TR-ROW-0326-00337) — Sidewalk Repair, Repouring Concrete.
Permit history (12)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2026-03-23finaled | TR-ROW-0326-00337City permit record | Right-of-Way (ROW)Sidewalk Repair, Repouring Concrete | Complete | |
| 2026-01-16finaled | TR-ROW-0126-00047City permit record | Right-of-Way (ROW)Repair of Sidewalk on Local Road | Complete | |
| 2025-07-07finaled 2025-09-15 | SD-0725-00103Design review | Historic Preservation Zone/Historic LandmarkRoof mount 5.22 kW DC photovoltaic solar system; 12 modules; 13.5 kWh Storage, 1 Tesla Powerwall-3 battery with integrated PV inverter with 1 string. 225A bus with 200A MCB, interconnection via PCS, Tesla Backup Switch for whole home backup. | Complete | |
| 2025-07-07finaled | TC-RES-0725-03396City permit record | Solar PVRoof mount 5.22 kW DC photovoltaic solar system; 12 modules; 13.5 kWh Storage, 1 Tesla Powerwall-3 battery with integrated PV inverter with 1 string. 225A bus with 200A MCB, interconnection via PCS, Tesla Backup Switch for whole home backup. | Complete | |
| 2025-07-07 | TE-FPU-0725-00266City permit record | Solar PVVOID - not in Floodplain; Roof mount 5.22 kW DC photovoltaic solar system; 12 modules; 13.5 kWh Storage, 1 Tesla Powerwall-3 battery with integrated PV inverter with 1 string. 225A bus with 200A MCB, interconnection via PCS, Tesla Backup Switch for whole home backup. | Void | |
| 2025-04-22finaled | TC-RES-0425-02141City permit record | Residential Building - One or Two Familyupgrade from 100 to 200 amp service | Complete | |
| 2024-12-30finaled | TC-RES-1224-07500City permit record | Addition / alterationLaundry Room Addition | Complete | |
| 2023-05-16finaled 2023-09-20 | SD-0523-00053Design review | Historic Preservation Zone/Historic LandmarkWe're proposing a room addition to the east side of the existing building. The project needs to go through Historic review first. | Complete |
Show 4 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2023-05-09expired 2024-11-05 | TC-RES-0523-05034City permit record | Addition / alterationVoid - Duplicate/Same scope of work as existing application permit number T21CM04896. Resubmit through existing permit T21CM04896 or withdraw existing permit. Existing application permit number T21CM04896. We're proposing a room addition to the east side of the existing building. The project needs to go through Historic review first. | Void | |
| 2023-04-18expired 2023-10-15 | TC-RES-0423-04543City permit record | Addition / alterationVoid - Duplicate/Same scope of work as existing application permit number T21CM04896. We're proposing a room addition to the east side of the existing building. The project needs to go through Historic review first. | Void | |
| 2021-06-11 | T21CM04896City permit record | Addition / alterationGuest house and the addition to the main house | Expired | |
| 2021-01-14 | T21CM00424City permit record | Residential Building - One or Two Family2nd Dwelling Unit. | Expired |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Planning work at this home?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, sent once. No list.One email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list.
How this report was built
This is a reading of public records for parcel 11710152A — 12 permits on file from 2021 to 2026 (4 addition / alteration, 2 right-of-way (row), 2 historic preservation zone/historic landmark, 2 solar pv) — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).