Electrical permit history — 330 E 13th St

330 E 13th St, Tucson — built 1906, with 7 permits on record. Review electrical, HVAC and remodel history with links to official records.

Home

330 E 13th St

Built 1906 — pre-1950 knob-and-tube era · 7 permits on record; no permitted panel/service or HVAC work among them

Parcel
11706270A
Built
1906 (county record)
Jurisdiction
Tucson
Zoning
HO-3
Assessor use
Sfr Grade 010-3 Non Conforming To Zoning
Parcel size
0.26 acres
Living area
2,130 sq ft (assessor record)
Cooling
Refrigeration (assessor record)
Heating
Forced Air (assessor record)
Roof
Asphalt (assessor record)
Garage
Garage (2-car) (assessor record)
Sewer
Connection on file (1973, 2012, 2018) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Armory Park Historic Residential District — Historic Preservation Zone (City of Tucson)
Typical original service for a 1906 home
approximately 30–60 A

See the property

County aerial photograph centered on 330 E 13th St, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & panelNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2015 solar pv permit is on file — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not tell you the service is original — only that nothing has been permitted here recently. The build year is the better clue, and it is above.
  • Heating & coolingNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2015 solar pv permit is on file — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. The assessor records cooling as Refrigeration and heating as Forced Air. Cooling equipment works harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes.
  • Water heaterNot in this windowNothing in the permit records we read for this parcel that names this system. Water heaters are frequently swapped without a permit, so this line is especially weak evidence either way.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. The assessor records the roof as Asphalt.
  • Plumbing work on recordNot in this windowNothing in the permit records we read for this parcel that names this system. Unremarkable — plenty of buildings never need a permitted plumbing repair.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Knob-and-tube wiring may still be present in original, un-remodeled areas. It has no ground and is not rated for modern loads or insulation contact. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check — high priority

    Original services this age were 30–60 A fuse panels. Nearly every one still in place is undersized for a modern household. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check — high priority

    Branch circuits from this era are typically ungrounded two-wire — the reason you see two-prong outlets or ungrounded three-prong replacements. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    A pool or spa was permitted in 2017. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.

  • Worth confirming

    Solar was permitted here in 2015. That means there is an existing interconnection, and the main breaker and busbar rating already carry a PV backfeed — so anything else you add (an EV charger, a heat pump) has to be checked against what is left under the 120% rule, not against the service size alone.

Recorded sales (2)

Recorded transfers from the Pima County Assessor — 2 of 2
DatePriceType
2012-08-24$305,000Warranty Deed
2003-04-07$236,000Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2025-07-16 (TC-RES-0725-03553) — Carport and Patio Covers.

Permit history (7)

Permit history for this parcel — 7 of 7 records
DateRecordWhatStatusValue
2025-07-16finaledTC-RES-0725-03553City permit recordResidential Building - One or Two FamilyCarport and Patio CoversInspections complete
2017-02-24finaledT17BU00085City permit recordPool / spaNEW POOLFinal
2015-08-13finaledT15CM05636City permit recordSolar PVINSTALL 15 PV SOLAR SYSTEM R1: MOVING MODULESFinal
2014-11-10expired 2016-03-01T14CM07666City permit recordCOMBOADD DETACHED GUEST QUARTERS WITH DETACHED GARAGEExpired
2013-06-04expired 2013-08-03T13EX00768City permit recordEXCAV20LF CURB CUT FOR DRIVEWAY APRON (S.D.206) INSTALLATION 5' FROM PROPERTY LINE.Closed
2012-10-11expired 2018-02-18T12CM06414City permit recordAddition / alterationPATIO ADDITION, KITCHEN AND BATH REMODEL R1- ADDT: PATIO AND 54' - 6' CMU WALL R3: REVISE FRAMING DESIGNExpired
2005-11-29finaledT05OT02931City permit recordSIGN10123Final

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this home?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 11706270A — 7 permits on file from 2005 to 2025 (1 residential building - one or two family, 1 pool / spa, 1 solar pv, 1 combo) — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.