Electrical permit history — 1619 E Hedrick Dr

1619 E Hedrick Dr, Tucson — built 1933, with 24 permits on record. Review electrical, HVAC and remodel history with links to official records.

Home

1619 E Hedrick Dr

Built 1933 — pre-1950 knob-and-tube era · 24 permits on record; no permitted panel/service or HVAC work among them

Parcel
113071300
Built
1933 (county record)
Jurisdiction
Tucson
Zoning
R-2
Assessor use
Mixed Complex 2/More Res 1 Story
Parcel size
0.55 acres
Sewer
Connection on file (1955, 2021, 2023) (county sewer connection records)
Flood zone
AE — Special Flood Hazard Area (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)
Typical original service for a 1933 home
approximately 30–60 A

See the property

County aerial photograph centered on 1619 E Hedrick Dr, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & panelNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2023 fire construction permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not tell you the service is original — only that nothing has been permitted here recently. The build year is the better clue, and it is above.
  • Heating & coolingNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2023 fire construction permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Cooling equipment works harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes.
  • Water heaterNot in this windowNothing in the permit records we read for this parcel that names this system. Water heaters are frequently swapped without a permit, so this line is especially weak evidence either way.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system.
  • Plumbing work on recordNot in this windowNothing in the permit records we read for this parcel that names this system. Unremarkable — plenty of buildings never need a permitted plumbing repair.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Knob-and-tube wiring may still be present in original, un-remodeled areas. It has no ground and is not rated for modern loads or insulation contact. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check — high priority

    Original services this age were 30–60 A fuse panels. Nearly every one still in place is undersized for a modern household. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check — high priority

    Branch circuits from this era are typically ungrounded two-wire — the reason you see two-prong outlets or ungrounded three-prong replacements. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    A pool or spa was permitted in 2021. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.

Most recent permit on record for this parcel: 2023-04-13 (TF-FCP-0423-00593) — Sprinkler System in new SFR per NFPA13D.

Permit history (24)

Permit history for this parcel — 8 of 24 records
DateRecordWhatStatusValue
2023-04-13finaledTF-FCP-0423-00593City permit recordFire ConstructionSprinkler System in new SFR per NFPA13DComplete
2023-04-13finaledTF-FCP-0423-00594City permit recordFire ConstructionAdd sprinkler system to new SFR per NFPA13DComplete
2023-02-27TE-FPU-0223-00115City permit recordFloodplain UseSite/Grading/Floodplain - The Hedricks. Add two units to an existing two-unit development.Issued
2023-02-27TE-FPU-0223-00116City permit recordFloodplain UseSite/Grading/Floodplain - The Hedricks. Add two units to an existing two-unit development.Issued
2023-02-20finaledTR-UTL-0223-00915City permit recordRight-of-Way (ROW) - UtilityWO T64770. TEP INSTALLING 40' STEEL POLE IN ROW AND TRANSFERRING ATTACHMENTS TO FIX VOLTAGE IN THE AREA AND PREPARE FOR NEW DUPLEX GOING IN AT 1617 & 1619 E HEDRICK DRComplete
2023-01-17expired 2023-07-16TC-COM-0123-00486City permit recordCommercial BuildingVoid incorrect permit type reference TC-MDP-0123-00330 New SFR rental model home under approved DP21-0362Expired
2023-01-17expired 2023-07-16TC-COM-0123-00491City permit recordCommercial BuildingUnable to process. The wrong permit type was applied for please apply for a New Residential Model Plan or New Permit from Approved Model Plan. This permit will be voided. New SFR rental model home under approved DP21-0362Void
2022-12-05finaledTC-MDP-0123-00330City permit recordModel BuildingSFR model Plan Alum 1585RComplete
Show 16 older records
Permit history for this parcel — remaining 16 records
DateRecordWhatStatusValue
2022-12-05expired 2024-01-22TC-MDP-0123-00331City permit recordModel Buildingmodel Plan Alum 1585RExpired
2021-12-30expires 2026-10-03DP21-0362City permit recordDevelopment PackageSite/Grading/Floodplain - The Hedricks. Add two units to an existing two-unit development.Issued
2021-06-03finaledT21BU00299City permit recordPool / spaNew Pool & SpaFinal
2021-05-25finaledT21RW02579City permit recordPool / spaWO 2102059, 2102062, 2102065 @ 1615, 1617, 1619 E Hedrick Dr in same trench across road new copper services PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. INGRESS/ EGRESS FOR BUSINESS AND RESIDENTIAL ACCESS SHALL BE MAINTAINED. FIELD ADJUSTMENTS MAY BE REQUIRED. PAVEMENT PATCHING IS NECESSARY WHERE PAVEMENT IS CUT. PATCH LIMITS- THE LIMITS OF THE PAVING SHALL BE A MINIMUM OF 1-FT OUTSIDE THE EXCAVATION. TRENCHES/ PITS CANNOT BE LEFT OPEN OVERNIGHT. MUST BE BACKFILLED AND PATCHED OR PLATED. POTHOLES SPACED CLOSELY TOGETHER AND WITHIN 8-FT OF EACH OTHER WILL NEED TO BE JOINED TOGETHER BY ONE SURFACE PATCH. BACKFILL WITH CLSM SLURRY OR AGGREGATE BASE COURSE (ABC.) ASPHALTIC CONCRETE USED SHALL BE CITY OF TUCSON MIX NO. 3 OR COT MIX NO. 2 WITH TR-22, INSPECTOR TO ADVISE. REPAIR ALL LANDSCAPING DISTURBED. THIS INCLUDES IRRIGATION, PLANTINGS, GROUNDCOVER, AND HARDSCAPE. GOOD HOUSEKEEPING MEASURES SHALL BE PRACTICED DURING WORK AND CONSTRUCTION MAINTAIN PEDESTRIAN ACCESSFinal
2021-04-29finaledT21RW02095City permit recordROWCURB CUT AND SIDEWALK FOR DRIVEWAY APRON PER SD206 FOR 1613-1615 E HEDRICK DR PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING.Final
2021-03-05expired 2021-09-06T21OT00167City permit recordFloodplain UseNew SFR to be built under Permit T21CM01383Issued
2021-03-05expired 2021-09-06T21OT00168City permit recordFloodplain UseNew SFR to be built under Permit T21CM01568Issued
2021-02-22finaledT21CM01568City permit recordCOMBOSFR ALUM158520 T20-M0006Final
2021-02-18finaledT21CM01383City permit recordCOMBOSFR ALUM158520 T20-M0006Final
2021-01-26T21CM00813City permit recordCOMBOSFR ALUM158520 T20-M0006Withdrwn
2020-07-29T20BU00273City permit recordDemolitionCOMPLETE DEMOLITIONVoid
2020-04-20expired 2021-08-02T20OT00321City permit recordFloodplain UseFUP FOR DP18-0239Issued
2019-07-18DS19-10City permit recordZoning Verification LetterHEDRICK SINGLE FAM DEV, TSMR - TSMR, 8-01.5.1.a - Trash bins/individual APCs.Approved
2019-04-15T19OT00340City permit recordFLOODPLNFUP FOR T19BU00171Issued
2019-04-08finaledT19BU00171City permit recordDemolitionDEMOLITIONFinal
2018-09-24DP18-0239City permit recordDEVPKGSITE/GRADING/FLOODPLAIN - Hedrick Development.Withdrwn

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (4)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 4 of 4 records
DateRecordWhatStatus
2023-05-01CE-VIO0523-03231Code enforcement caseVegetationClosed - resolved
2015-11-20T15DV09023Code enforcement caseVegetationComplian
2011-09-27T11DV07703Code enforcement caseCode enforcement caseComplian
2008-08-19T08DV07360Code enforcement caseVegetationComplian

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this home?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 113071300 — 24 permits on file from 2018 to 2023 (5 floodplain use, 3 combo, 2 fire construction, 2 commercial building) and 4 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.