Electrical permit history — 1034 E Prince Rd

1034 E Prince Rd, Tucson — built 1957, with 8 permits on record. Review electrical, HVAC and remodel history with links to official records.

Home

1034 E Prince Rd

Built 1957 — post-war 60–100 A service era · 8 permits on record; no permitted panel/service or HVAC work among them

Parcel
113040760
Built
1957 (county record)
Jurisdiction
Tucson
Zoning
R-2
Assessor use
Sfr Grade 010-3 Urban Subdivided
Parcel size
0.24 acres
Sewer
Connection on file (1958) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)
Typical original service for a 1957 home
approximately 60–100 A

See the property

County aerial photograph centered on 1034 E Prince Rd, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Flood and drainage — two different maps

The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map. Pima County’s Regional Flood Control District and the City of Tucson regulate against their own, and that is the one a permit here is judged against.

FEMA flood hazard (federal)
FEMA flood hazard (federal) for 1034 E Prince Rd, Tucson area, Arizona

FEMA National Flood Hazard Layer — zones and base-flood-elevation contours. Federal insurance mapping. Open this property on FEMA’s official flood map ↗

Local regulatory floodplain (county and City)
Local regulatory floodplain (county and City) for 1034 E Prince Rd, Tucson area, Arizona

Pima County RFCD local floodplains, floodways, sheet-flooding and erosion hazard areas, with the City of Tucson’s own mapped flood hazards. This is the map local floodplain regulation uses.

Parcel outlined in yellow. Both maps are drawn live from the agencies’ own map services at the same extent, so you can compare them directly. They are context for planning, not a floodplain determination — for that, ask the floodplain administrator for the jurisdiction shown below.

  • FEMA: FEMA flood zone X — minimal flood hazard, not a Special Flood Hazard Area. FIRM panel 04019C1689L, effective 2011-06-16.
  • Pima County RFCD: No Pima County regulated local floodplain, floodway, sheet-flooding area or erosion hazard area is mapped at this location. That is the county's map, not a statement about drainage on the site.

Is it time to upgrade?

  • Electrical service & panelNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2023 residential building - one or two family permit is on file — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not tell you the service is original — only that nothing has been permitted here recently. The build year is the better clue, and it is above.
  • Heating & coolingNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2023 residential building - one or two family permit is on file — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Cooling equipment works harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes.
  • Water heaterNot in this windowNothing in the permit records we read for this parcel that names this system. Water heaters are frequently swapped without a permit, so this line is especially weak evidence either way.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system.
  • Plumbing work on recordNot in this windowNothing in the permit records we read for this parcel that names this system. Unremarkable — plenty of buildings never need a permitted plumbing repair.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    60–100 A was standard. That is enough for a mid-century house, not for a modern kitchen, HVAC, and an EV. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check — high priority

    Federal Pacific (Stab-Lok) and Zinsco/Sylvania panels were sold through this period. Stab-Lok breakers have a documented history of failing to trip internally; Zinsco breakers can weld to the bus so the handle moves without breaking the circuit. In both cases a replacement breaker does not resolve it — the panel itself is what gets replaced. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    Grounded branch circuits did not become the norm until the early 1960s — much of the original wiring here is likely ungrounded. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    Cloth-jacketed NM cable is common in this era. The jacket embrittles with age and heat, particularly in Tucson attics. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    There is an electrical reconnect permit from 2019. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.

Most recent permit on record for this parcel: 2024-07-01 (TC-SOL-0724-00150) — Roof mounted Solar system..

Permit history (8)

Permit history for this parcel — 8 of 8 records
DateRecordWhatStatusValue
2024-07-01expired 2025-02-03TC-SOL-0724-00150City permit recordSolar PVRoof mounted Solar system.Issued
2023-06-24expired 2023-12-21TC-RES-0623-06110City permit recordResidential Building - One or Two FamilyVoid - Duplicate/Same scope of work as existing application permit number TC-RES-0323-03579. Please submit revision under existing permit. Install new 3.5 ton package systemVoid
2023-04-18expired 2023-10-15TC-RES-0423-04530City permit recordResidential Building - One or Two FamilyVOIDED INCLUDE SCOPE OF WORK UNDER PERMIT TC-RES-0323-03579 Complete Electrical wiring of this Location .Void
2023-03-14finaledTC-RES-0323-03579City permit recordResidential Building - One or Two FamilyCE-VIO1122-00737 Remodel SFRComplete
2023-03-14expired 2023-09-10TC-RES-0323-03580City permit recordResidential Building - One or Two FamilyUpgrade the electrical panel to 200 amps.Expired
2023-01-24expired 2023-07-23TC-RES-0123-02339City permit recordResidential Building - One or Two FamilyVOID: This permit application will be voided. This is a duplicate of another permit for the same scope of work for this same address/parcel (TC-RES-1122-00707). Please proceed with the other permit (TC-RES-1122-00707). - Upgrade elect to 200ampVoid
2022-11-11expired 2023-10-03TC-RES-1122-00707City permit recordResidential Building - One or Two FamilyPanel upgrade to 200 amps.Approved
2019-10-18finaledT19CM07718City permit recordElectrical reconnectELECTRICAL RECONNECTFinal

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (18)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 8 of 18 records
DateRecordWhatStatus
2022-11-29CE-VIO1122-00737Code enforcement caseCode enforcement caseClosed - resolved
2022-08-19T22DV04824Code enforcement caseCode enforcement caseClosed - resolved
2022-04-26T22DV02641Code enforcement caseRefuseClosed - resolved
2020-07-30T20DV05162Code enforcement caseVegetationReferred
2019-11-04T19DV08667Code enforcement caseCode enforcement caseComplian
2019-10-03T19DV07705Code enforcement caseCode enforcement caseComplian
2019-01-30T19DV00515Code enforcement caseVegetationCourtcmp
2017-08-30T17DV04135Code enforcement caseVegetationWp compl
Show 10 older records
Code enforcement history for this parcel — remaining 10 records
DateRecordWhatStatus
2017-02-16T17DV00685Code enforcement caseRefuseComplian
2016-08-31T16DV05284Code enforcement caseVegetationComplian
2016-06-06T16DV03328Code enforcement caseRefuseComplian
2015-10-07T15DV07662Code enforcement caseVegetationComplian
2008-09-11T08DV08442Code enforcement caseVegetationComplian
2008-08-19T08DV07303Code enforcement caseCode enforcement caseNoverify
2007-09-26T07DV09827Code enforcement caseRefuseComplian
2007-09-20T07DV09401Code enforcement caseVegetationComplian
2007-08-09T07DV07449Code enforcement caseRefuseComplian
2007-03-07T07DV02143Code enforcement caseCode enforcement caseCancel

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.

In the public record: All homes in 85719 · Homes by ZIP code · Commercial property in 85719 · Permit data by neighborhood

Planning work at this home?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 113040760 — 8 permits on file from 2019 to 2024 (6 residential building - one or two family, 1 solar pv, 1 electrical reconnect) and 18 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-18; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.