Electrical permit history — 1231 E Haven Ln
1231 E Haven Ln, Tucson — built 1971, with 4 permits on record. Review electrical, HVAC and remodel history with links to official records.
Electrical Property Screening Report · Home
1231 E Haven Ln
A screening report for electrical planning, assembled from public-record indicators. It is not an official record and every figure in it should be verified against the issuing agency before it is relied on.
Verify parcel data at official source ↗
Built 1971 — possible aluminum-wiring era — based on year only, not observed · 4 permits on record; no permitted panel/service or HVAC work among them
Permanent link: Electrical permit history for 1231 E Haven Ln (aztucsonelectricalsolutions.com/property/113040290/1231-e-haven-ln-tucson-az-85719) · Public records last checked 2026-08-19
Public record indicators for electrical planning
- Parcel
- 113040290
- Year constructed
- 1971 (county record)
- Permitting authority
- Tucson
- Zoning
- R-2
- Lot size
- 0.33 acres
- Sewer
- Connection on file (1971) (county sewer connection records)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
- Estimated electrical service era
- approximately 100 A (estimated from the year built, 1971 — not a measurement; verify on site)
See the property
Satellite imagery © Google. Imagery can predate recent work and shows nothing about what is inside — context, not evidence.
Flood and drainage
The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.
- FEMA: FEMA flood zone X — minimal flood hazard, not a Special Flood Hazard Area. FIRM panel 04019C1689L, effective 2011-06-16. Open this property on FEMA’s official flood map ↗
- Local floodplain (the City of Tucson): local floodplain mapping is not reproduced here. A property can sit outside FEMA’s zone and still be inside a locally regulated floodplain, floodway, sheet-flooding area or erosion hazard setback, so check the authority’s own map before planning work. Pima County RFCD flood hazard map for parcel 113040290 ↗ · the City of Tucson ↗
Is it time to upgrade?
- Electrical service & panelNot in this windowNothing in the permit records we read for this parcel that names this system. That does not tell you the service is original — only that nothing has been permitted here recently. The build year is the better clue, and it is above.
- Heating & coolingNot in this windowNothing in the permit records we read for this parcel that names this system. Cooling equipment works harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes.
- Water heaterNot in this windowNothing in the permit records we read for this parcel that names this system. Water heaters are frequently swapped without a permit, so this line is especially weak evidence either way.
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system.
- Plumbing work on recordNot in this windowNothing in the permit records we read for this parcel that names this system. Unremarkable — plenty of buildings never need a permitted plumbing repair.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitized. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check — high priority
This is the aluminum branch-circuit window (roughly 1965–1973). Solid aluminum on 15/20 A circuits is a recognized fire hazard at the terminations and needs approved repair — COPALUM or AlumiConn, not a wire nut. The permit record does not confirm this; an on-site inspection is required.
- Era-based check — high priority
Federal Pacific (Stab-Lok) and Zinsco/Sylvania panels were sold through this period. Stab-Lok breakers have a documented history of failing to trip internally; Zinsco breakers can weld to the bus so the handle moves without breaking the circuit. In both cases a replacement breaker does not resolve it — the panel itself is what gets replaced. The permit record does not confirm this; an on-site inspection is required.
- Era-based check
100 A was typical for the era. Adding an EV charger, heat pump or casita requires a load calculation; an upgrade or a load-management device may be needed. The permit record does not confirm this; an on-site inspection is required.
- Worth confirming
There is an electrical reconnect permit from 2012. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.
The most recent permitted work on this parcel was in 2024. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.
What this means for work here
Informational public-record summary — not engineering, inspection, valuation or purchasing advice, and not the official record.
The most recent permitted work on this parcel was in 2024. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.
What that reading rests on. The issuing offices hold 4 building permits for this parcel dated between 2012 and 2024. By category the work is residential building - one or two family and row. 3 of them carry a final inspection; the other one was issued, expired or is still open, which is not the same as work completed. There are 14 code-enforcement cases recorded against the parcel, all of them closed. We do not reproduce complaint text — it routinely names people with no connection to the property.
Go straight to the records
Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.
City permit record (4): 2024 TC-RES-1024-05899 · 2021 T21RW04185 · 2013 T13CM04148 · 2012 T12CM07644
Code enforcement cases (14): 2024 CE-VIO0524-02041 · 2009 T09DV04740 · 2009 T09DV04741 · 2009 T09DV04742 · 2009 T09DV04361 · 2009 T09DV00027 · 2008 T08DV05501 · 2007 T07DV11224 · 2007 T07DV07522 · 2007 T07DV04936 · 2007 T07DV03154 · 2007 T07DV00920 · 2006 T06FR00615 · 2006 T06VL00311
Read the records yourself. We republish selected facts and record numbers so you can find the file; the issuing agency’s record controls. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 113040290. Permit and parcel information courtesy of the City of Tucson and Pima County; their files are the official record and control over anything summarized here.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.
In the public record: All homes in 85719 · Homes by ZIP code · Commercial property in 85719 · Permit data by neighborhood
Planning work at this home?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, sent once. No list.One email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list.
What the flood note is not. The flood zone shown is FEMA’s National Flood Hazard Layer — the federal insurance map. Local floodplain mapping is not reproduced here; use the authority’s own map, linked above. Nothing here is a floodplain determination, an elevation certificate, or a substitute for one. A parcel can straddle a boundary, and a Letter of Map Amendment can remove a structure the map still covers. For a determination, ask the floodplain administrator for the jurisdiction named above; for a design that has to satisfy one, that is work we do.
How this report was built
This is a reading of public records for parcel 113040290 — 4 permits on file from 2012 to 2024 (2 combo, 1 residential building - one or two family, 1 row) and 14 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-19; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.