Electrical permit history — 2111 E Florence Dr
2111 E Florence Dr, Tucson — built 1957, with 6 permits on record. Review electrical, HVAC and remodel history with links to official records.
Home
2111 E Florence Dr
Built 1957 — post-war 60–100 A service era · last permitted panel/service work 2007 (finaled) · HVAC 2007 (permit expired without a confirmed final)
Permanent link: Electrical permit history for 2111 E Florence Dr (aztucsonelectricalsolutions.com/property/112051810/2111-e-florence-dr-tucson-az-85719) · Public records last checked 2026-08-19
- Parcel
- 112051810
- Built
- 1957 (county record)
- Jurisdiction
- Tucson
- Zoning
- R-1
- Assessor use
- Sfr Grade 010-3 Urban Subdivided
- Parcel size
- 0.21 acres
- Living area
- 1,658 sq ft (assessor record)
- Cooling
- Evaporative (assessor record)
- Heating
- Forced Air (assessor record)
- Roof
- Wood (assessor record)
- Garage
- Garage (2-car) (assessor record)
- Sewer
- Connection on file (1957) (county sewer connection records)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
- Typical original service for a 1957 home
- approximately 60–100 A
- Service on record
- City records show the 2007 permit was finalized; the permit description states “ELECTRIC SERVICE UPGRADE(APA)” — an increase in capacity as described, not a confirmed installed rating.
See the property
Satellite imagery © Google. Imagery can predate recent work and shows nothing about what is inside — context, not evidence.
Flood and drainage
The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.
- FEMA: FEMA flood zone X — minimal flood hazard, not a Special Flood Hazard Area. FIRM panel 04019C1689L, effective 2011-06-16. Open this property on FEMA’s official flood map ↗
- Local floodplain (the City of Tucson): local floodplain mapping is not reproduced here. A property can sit outside FEMA’s zone and still be inside a locally regulated floodplain, floodway, sheet-flooding area or erosion hazard setback, so check the authority’s own map before planning work. Pima County RFCD flood hazard map for parcel 112051810 ↗ · the City of Tucson ↗
Is it time to upgrade?
- Electrical service & panelCurrentLast permitted 2007 (19 years ago). City inspection record: ELECTRIC - FINAL approved 2007-02-07. Contractor of record: HAECO ENTERPRISES L L C ,*C. The permit describes an increase in capacity, which is the single best sign the electrical has actually been brought forward. T07EL00159 — ELECTRIC SERVICE UPGRADE(APA)
- Heating & coolingPermitted — completion not confirmedA 2007 permit specifies this work (the permit description states “REPLACE: 5 TON SPLIT SYSTEM (APA)”), but the available record does not show a final inspection. The permit expired without a confirmed final status. Official status: Expired. Contractor of record: PUEBLO HEATING & COOLING INC *C. The assessor records cooling as Evaporative and heating as Forced Air. T07ME00039 — REPLACE: 5 TON SPLIT SYSTEM (APA)
- Water heaterNot in this windowNothing in the permit records we read for this parcel that names this system. Water heaters are frequently swapped without a permit, so this line is especially weak evidence either way.
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. The assessor records the roof as Wood.
- Plumbing work on recordNot in this windowNothing in the permit records we read for this parcel that names this system. Unremarkable — plenty of buildings never need a permitted plumbing repair.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check — high priority
60–100 A was standard. That is enough for a mid-century house, not for a modern kitchen, HVAC, and an EV. The permit record does not confirm this; an on-site inspection is required.
- Era-based check — high priority
Federal Pacific (Stab-Lok) and Zinsco/Sylvania panels were sold through this period. Stab-Lok breakers have a documented history of failing to trip internally; Zinsco breakers can weld to the bus so the handle moves without breaking the circuit. In both cases a replacement breaker does not resolve it — the panel itself is what gets replaced. The permit record does not confirm this; an on-site inspection is required.
- Era-based check
Grounded branch circuits did not become the norm until the early 1960s — much of the original wiring here is likely ungrounded. The permit record does not confirm this; an on-site inspection is required.
- Era-based check
Cloth-jacketed NM cable is common in this era. The jacket embrittles with age and heat, particularly in Tucson attics. The permit record does not confirm this; an on-site inspection is required.
- Worth confirming
A pool or spa was permitted in 2024. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.
- Worth confirming
Solar was permitted here in 2021. That means there is an existing interconnection, and the main breaker and busbar rating already carry a PV backfeed — so anything else you add (an EV charger, a heat pump) has to be checked against what is left under the 120% rule, not against the service size alone.
Ownership changes. The Pima County Assessor has 1 recorded transfer on file for this parcel, the most recent in 2021. The dates, prices and deed types are the Assessor’s to publish and stay on their record. It matters here for one reason: a property that changed hands with no permitted electrical work since is usually running whatever the previous owner left. See the Assessor’s record for this parcel ↗
The most recent permitted work on this parcel was in 2024 — recent enough that the current code cycle applied. Work done without a permit leaves no trace here at all.
What this means for work here
The most recent permitted work on this parcel was in 2024 — recent enough that the current code cycle applied. Work done without a permit leaves no trace here at all.
What that reading rests on. The issuing offices hold 6 building permits for this parcel dated between 2007 and 2024. By category the work is residential building - one or two family, pool / spa and solar pv. 5 of them carry a final inspection; the other one was issued, expired or is still open, which is not the same as work completed. There are 5 code-enforcement cases recorded against the parcel, all of them closed. We do not reproduce complaint text — it routinely names people with no connection to the property.
Go straight to the records
Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.
City permit record (6): 2024 TC-RES-1124-06651 · 2024 TC-RES-0524-02940 · 2021 T21CM02911 · 2015 T15CM00009 · 2007 T07EL00159 · 2007 T07ME00039
Code enforcement cases (5): 2018 T18DV04468 · 2013 T13DV01792 · 2007 T07DV06203 · 2007 T07DV06030 · 2007 T07DV05874
Read the records yourself. This report is our reading of the public record; we do not republish it. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 112051810.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.
In the public record: All homes in 85719 · Homes by ZIP code · Commercial property in 85719 · Permit data by neighborhood
Planning work at this home?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, sent once. No list.One email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list.
What the flood note is not. The flood zone shown is FEMA’s National Flood Hazard Layer — the federal insurance map. Local floodplain mapping is not reproduced here; use the authority’s own map, linked above. Nothing here is a floodplain determination, an elevation certificate, or a substitute for one. A parcel can straddle a boundary, and a Letter of Map Amendment can remove a structure the map still covers. For a determination, ask the floodplain administrator for the jurisdiction named above; for a design that has to satisfy one, that is work we do.
How this report was built
This is a reading of public records for parcel 112051810 — 6 permits on file from 2007 to 2024 (1 residential building - one or two family, 1 pool / spa, 1 solar pv, 1 combo) and 5 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-19; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.