Electrical permit history — 2525 E Prince Rd

2525 E Prince Rd, Tucson — with 36 permits on record. Review electrical, HVAC and remodel history with links to official records.

Electrical Property Screening Report · Home

2525 E Prince Rd

A screening report for electrical planning, assembled from public-record indicators. It is not an official record and every figure in it should be verified against the issuing agency before it is relied on.

Verify parcel data at official source ↗

Build year not published — permits on file from 1999 · last permitted panel/service work 2015 (finaled) · HVAC 2020 (finaled); a newer 2025 permit is issued

Is it time to upgrade?

  • Electrical service & panelFinaled permit foundLast permitted 2015 (11 years ago). Worth reading the permit itself: it names the service but does not read as an increase in capacity, so this may have been a like-for-like replacement rather than an upgrade. T15CM01790 — REPLACE 125 AMP MAIN BREAKER FOR TOWNHOUSE - TEP METER CHANGEOUT PROGRAM (APA)
  • Heating & coolingFinaled permit foundA newer 2025 permit for the same system is recorded as “Issued” — The work was permitted, but final completion is not confirmed. The permit description states “3 ton gas package unit changeout on the roof”. Last permitted 2020 (6 years ago). Cooling equipment works harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. T20CM06450 — REPLACEMENT OF A/C UNIT
  • Water heaterLikely dueLast permitted 2013 (13 years ago). T13CM03013 — REPLACE WATER HEATER
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system.
  • Plumbing work on recordNot in this windowNothing in the permit records we read for this parcel that names this system. Unremarkable — plenty of buildings never need a permitted plumbing repair.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitized. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    A finaled 2015 panel/service permit is on record for this parcel, which makes it unlikely the original 200 A equipment is still in place. That is a permit record, not an inspection — verify the installed rating and the panel brand on site before sizing anything new. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    AFCI protection did not enter the code until the 1999 NEC (bedroom circuits, effective 2002) and was not expanded to most living areas until 2008 — so houses from the earlier part of this range typically have none at all. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    Solar was permitted here in 2017. That means there is an existing interconnection, and the main breaker and busbar rating already carry a PV backfeed — so anything else you add (an EV charger, a heat pump) has to be checked against what is left under the 120% rule, not against the service size alone.

  • Worth confirming

    There is an electrical reconnect permit from 2014. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.

  • Routine

    A trade permit was pulled in 2020. Trade permits cover electrical, plumbing, and mechanical work individually, so some permitted trade work has been done here since.

What to check at the panel

Everything above is read off public records. These are the things only someone standing at the panel can settle, and they take about a minute. Check them against the rating the permit above describes rather than against the era — the permit is the better evidence, and neither one is an inspection.

  1. The number stamped on the main breaker handle — 100, 125, 150, 175 or 200. That is the service rating, and no record on this page confirms it.
  2. The busbar rating printed on the panel label. It is a different number from the main breaker, and it is the one that decides how much solar a panel can take under the 120% rule.
  3. The manufacturer and catalog number on the label inside the door.
  4. How many full-size spaces are left, how many positions the label permits a tandem breaker in, and the tandem limit the label states. A full panel is a different job from a full service.
  5. The conductor material at the main lugs, and whether the terminations look clean and tight.
  6. Whether there is a separate meter-main outside as well as the panel indoors — that changes where a disconnect and any new feeder would land.
  7. Whether the water heater, dryer and range are gas or electric. No public record carries fuel type, and it is the single biggest variable in a load calculation — it can move the calculated load on the same house by more than 40 A.

With those in hand you can run the numbers yourself. The load calculator does the NEC 220.82 optional-method calculation — the same method a permit application uses — and shows its work.

Open the load calculator →

What these jobs cost here

The cooling equipment here was permitted in 2020 — replacement is not due yet.

Electrical panel or service upgrade

$3,800

Most jobs like this land between $3,400 and $4,700.

The bottom of this range is a clean, simple job: single storey, framed wall, the panel staying where it is, a short service run, and nothing unexpected once the cover comes off. That job is real and we do book it — but it is the best case, not the average, and the figure above it is what most houses actually come to.

Priced from built 1999 (200 A, pre-2008 AFCI-code era), City of Tucson permit fee and the 2023 NEC it has adopted, Tucson Electric Power as the serving utility and a finalled permit recording a 125 A service, which is below 200 A — the upgrade is genuinely still open here.

What would move this price
  • Only if the panel has to move — a clothes closet, a bathroom, over a stairway, or behind a door +$3,900

If every one of those turned out to apply, this becomes about $8,600. That is the worst realistic case, not a prediction — none of them is a claim about your house.

Before you spend anything
  • A service upgrade fixes capacity and the safety of the service equipment. It does not fix branch wiring. If the reason you are here is flickering lights, warm outlets or cloth-jacketed wiring, an upgrade is a down payment on a much bigger problem, and it is worth knowing that before you spend in the wrong order. (The report reserves the era-specific wiring checks for the years they actually apply to — read those above.)
  • You may not need the upgrade at all. NEC 220.87 lets an existing dwelling be sized from twelve months of actual metered demand rather than a calculated load, and real houses draw far less than the calculation predicts. Ask your utility for a year of interval data and have it run that way first. Two cautions so this does not backfire: the demand tile in a TEP online account shows on-peak demand only, which is not the annual maximum the code asks for — you want the formal usage-data release — and 220.87 proves CAPACITY and nothing else. It does not create empty breaker spaces, and it does not make an obsolete panel, or one whose breakers have a documented failure history, safe. Those are separate questions with separate answers — and where the era makes a brand worth checking, the report above says so on its own.

A finalled HVAC permit from 2020 is on record, so the equipment is inside its expected life and we are not pricing a replacement.

What the record cannot tell us
  • Whether the service is already 200 A. Nothing in the public record says so, and the number is stamped on the main breaker handle.
  • Whether the panel can stay where it is. A panel in a closet, over stairs or behind a door has to move, and that alone adds $1,500 to $5,000.
  • Whether the service comes in overhead or underground. This is priced as overhead; an underground service with an adequate lateral is a few hundred dollars cheaper, and one with an undersized lateral is thousands more.

This is an estimate, not a quote. It is built from this property’s public record and current City of Tucson market rates — nobody has seen your panel, your duct or your roof. A real price comes from a site visit, and the things that move it most are the ones listed above that no record carries.

Price it for your house →

Change the assumptions — the panel’s location, the duct, the tonnage, whether the service is overhead or underground — and watch the number move. That is the point of it.

Solar potential

The county’s building-footprint layer maps ≈ 3,134 sq ft of roof plan area here. In Tucson a rooftop array produces about 1,645 kWh per installed kW per year (PVWatts), so a typical 6–8 kW home system fits on a fraction of that roof and makes roughly 10,000–13,000 kWh a year. TEP credits exported surplus at its RCP rate — about 5¢/kWh for new applications, locked for 10 years — so sizing to the home’s own use matters more than filling the roof. If solar shows in this property’s permit record, check whether it was permitted and finaled.

Flood and drainage

The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.

The record behind this read

Parcel
112012160
Year constructed
1999 (earliest permit on file)
Permitting authority
Tucson
Zoning
R-2
Estimated electrical service era
approximately 200 A (estimated from the year built, 1999 — not a measurement; verify on site)
Service on record
City records show the 2015 permit was finalized; the permit description states “REPLACE 125 AMP MAIN BREAKER FOR TOWNHOUSE - TEP METER CHANGEOUT PROGRAM (APA)”.

The most recent permitted work on this parcel was in 2025. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What this means for work here

Informational public-record summary — not engineering, inspection, valuation or purchasing advice, and not the official record.

The most recent permitted work on this parcel was in 2025. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What that reading rests on. The issuing offices hold 36 building permits for this parcel dated between 1999 and 2025. By category the work is trade permit (27), solar pv (6), right-of-way (row) permit - utility emergency (2) and right-of-way (row) permit - general. 26 of them carry a final inspection; the other 10 were issued, expired or are still open, which is not the same as work completed. There are 10 code-enforcement cases recorded against the parcel, all of them closed. We do not reproduce complaint text — it routinely names people with no connection to the property.

Go straight to the records

Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.

Read the records yourself. We republish selected facts and record numbers so you can find the file; the issuing agency’s record controls. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 112012160. Permit and parcel information courtesy of the City of Tucson and Pima County; their files are the official record and control over anything summarized here.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.

In the public record: All homes in 85716 · Homes by ZIP code · Commercial property in 85716 · Permit data by neighborhood

Planning work at this home?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

What the flood note is not. The flood zone shown is FEMA’s National Flood Hazard Layer — the federal insurance map. Local floodplain mapping is not reproduced here; use the authority’s own map, linked above. Nothing here is a floodplain determination, an elevation certificate, or a substitute for one. A parcel can straddle a boundary, and a Letter of Map Amendment can remove a structure the map still covers. For a determination, ask the floodplain administrator for the jurisdiction named above; for a design that has to satisfy one, that is work we do.

How this property compares nearby

Built in 1999 — earlier than about 5% of the 9,043 homes in ZIP 85716. Properties on E PRINCE RD hold 156 City permits on record, 34 of them since 2022.

Computed from the same public records as this report — counts and years, not an appraisal.

Complete permit record (46 entries)

Every permit and case we hold for this parcel, newest first. Each number links to the official file.

YearNumberTypeStatus
2026CE-VIO0726-02881SignClosed - Unfounded
2025TC-RES-0625-02809Residential Trade PermitIssued
2025recordRight-of-Way (ROW) Permit - Utility EmergencyComplete
2024TC-RES-0524-03194Residential Trade PermitExpired
2024TC-RES-1223-10286Residential Solar PermitIssued
2024TC-RES-0124-00065Residential Solar PermitWithdrawn
2023TC-RES-0923-08260Residential Solar PermitIssued
2023recordRight-of-Way (ROW) Permit - Utility EmergencyComplete
2022recordRight-of-Way (ROW) Permit - GeneralComplete
2021T21DV07918WEEDSREFERRED
2021T21DV05446REFUSENOVERIFY
2020T20CM06450Commercial Trade PermitComplete
2020T20DV04323JUNK MOTOR VEHICLESREFERRED
2020T20DV02702PROP MAINT MULTIPLE TYPESNOVERIFY
2017T17CM02769Residential Solar PermitComplete
2017T17CM01308Residential Solar PermitComplete
2016T16DV07138ENVIRONMENTALCOMPLIAN
2016T16DV03877EMERGENCYCOMPLIAN
2016T15CM08536Residential Solar PermitCanceled
2015T15DV09305RESIDENTIAL ZONINGCANCEL
2015T15CM06848Commercial Trade PermitComplete
2015T15CM02875Residential Trade PermitComplete
2015T15CM01790Residential Trade PermitComplete
2014T14CM06347Residential Trade PermitComplete
2013T13CM05167Commercial Trade PermitComplete
2013T13ME00077Commercial Trade PermitComplete
2013T13CM03013Residential Trade PermitComplete
2013T13DV03308EMERGENCYCOMPLIAN
2013T13CM01637Residential Trade PermitComplete
2012T12EL00238Commercial Trade PermitWithdrawn
2012T12EL00239Commercial Trade PermitWithdrawn
2012T12EL00240Residential Trade PermitWithdrawn
2012T12EL00241Residential Trade PermitComplete
2011T11EL02390Residential Trade PermitComplete
2011T11PL00418Residential Trade PermitComplete
2010T10PL00669Residential Trade PermitComplete
2010T10DV01846RES: MINIMUM HOUSINGNOVERIFY
2010T10EL00710Residential Trade PermitComplete
2009T09EL00862Commercial Trade PermitComplete
2008T08ME00331Residential Trade PermitComplete
2007T07ME00560Residential Trade PermitComplete
2006T06PL00022Residential Trade PermitComplete
2004T04EL00918Commercial Trade PermitComplete
2002T02PL01744Residential Trade PermitComplete
1999T99PL02322Residential Trade PermitComplete
1999T99ME01005Residential Trade PermitCanceled

prints this report — permits, comparisons and sources — as a clean document

How this report was built

This is a reading of public records for parcel 112012160 — 36 City permits on file from 1999 to 2025 and 10 code enforcement cases — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive, whose records reach back to the mid-1990s. Some records were still not read for this snapshot: City permit records before the mid-1990s were never fully digitized. The assessor’s building record, the sewer connection file and the flood map were also not read for this snapshot. Absence of a permit here is NOT evidence work was never permitted — it may predate the digitized record or sit in a system this snapshot did not read. Public records snapshot taken 2026-08-22.

The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.