Electrical permit history — 3138 N Placita Agua Caliente
3138 N Placita Agua Caliente
- Electrical service: no service or panel permit on record — normal for a house built in 2001, which started at about 200 A.
- Watch for: built 2001, before AFCI breakers were required in most rooms.
- Other work on record: heat pump replaced 2015, new-construction permit 2000, fence or wall permit 2000.
From City of Tucson permits and the Pima County Assessor, checked 13 Nov 2026. Not an inspection.
The permanent link and the summary above, sent once. No list.One email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list.
Is it time to upgrade?
Probably not: no service work is on record, which is normal for a house built in 2001.
- Electrical service & panelLooks currentNo service or panel permit on record — normal for a house built in 2001, which started at about 200 A.
- Heating & coolingLooks currentLast permitted 2015 (11 years ago) — the permit passed final inspection. The assessor records cooling as Refrigeration and heating as Forced Air. Cooling equipment works harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. T15CM03808 — REPLACE 5 TON HEAT PUMP AND 3 TON SPLIT SYSTEM (APA)
- Water heaterWorth checkingNo permit on record names this system. Water heaters are frequently swapped without a permit, so this line is especially weak evidence either way.
- RoofWorth checkingNo permit on record names this system. The assessor records the roof as Built Up.
What that usually means electrically
- Era-based check
AFCI protection did not enter the code until the 1999 NEC (bedroom circuits, effective 2002) and was not expanded to most living areas until 2008 — so houses from the earlier part of this range typically have none at all.
- Era-based check
200 A is typical and is usually adequate — worth confirming the panel has physical space before planning new loads.
What to check at the panel
These are the things only someone standing at the panel can settle — about a minute’s work.
- The number stamped on the main breaker handle — 100, 125, 150, 175 or 200. That is the service rating, and no record on this page confirms it.
- The busbar rating printed on the panel label. It is a different number from the main breaker, and it is the one that decides how much solar a panel can take under the 120% rule.
- The manufacturer and catalog number on the label inside the door.
- How many full-size spaces are left, how many positions the label permits a tandem breaker in, and the tandem limit the label states. A full panel is a different job from a full service.
- The conductor material at the main lugs, and whether the terminations look clean and tight.
- Whether there is a separate meter-main outside as well as the panel indoors — that changes where a disconnect and any new feeder would land.
- Whether the water heater, dryer and range are gas or electric. No public record carries fuel type, and it is the single biggest variable in a load calculation — it can move the calculated load on the same house by more than 40 A.
With those in hand you can run the numbers yourself. The load calculator does the NEC 220.82 optional-method calculation — the same method a permit application uses — and shows its work. It offers to start from the 2,137 sq ft on the assessor record; every other value is yours to enter. Open the load calculator
What these jobs cost here
The cooling equipment here was permitted in 2015 — replacement is not due yet.
Electrical panel or service upgrade Estimate
$3,800
Most jobs like this land between $3,400 and $4,700.
The bottom of this range is a clean, simple job: single storey, framed wall, the panel staying where it is, a short service run, and nothing unexpected once the cover comes off. That job is real and we do book it — but it is the best case, not the average, and the figure above it is what most houses actually come to.
Priced from built 2001 (200 A, pre-2008 AFCI-code era); City of Tucson permit fee and the 2023 NEC it has adopted.
Priced with Tucson Electric Power’s charges — TEP serves the City of Tucson. The assessor records framed walls, so no masonry drilling or stucco patch is priced.
What would move this price
- Only if the panel has to move — a clothes closet, a bathroom, over a stairway, or behind a door +$3,900
If every one of those turned out to apply, this becomes about $8,600. That is the worst realistic case.
- A service upgrade fixes capacity and the safety of the service equipment. It does not fix branch wiring. If the reason you are here is flickering lights, warm outlets or cloth-jacketed wiring, an upgrade is a down payment on a much bigger problem, and it is worth knowing that before you spend in the wrong order.
- You may not need the upgrade at all. NEC 220.87 lets an existing dwelling be sized from twelve months of actual metered demand rather than a calculated load, and real houses draw far less than the calculation predicts. Ask your utility for a year of interval data and have it run that way first. Two cautions so this does not backfire: the demand tile in a TEP online account shows on-peak demand only, which is not the annual maximum the code asks for — you want the formal usage-data release — and 220.87 proves CAPACITY and nothing else. It does not create empty breaker spaces, and it does not make an obsolete panel, or one whose breakers have a documented failure history, safe. Those are separate questions with separate answers — and where the era makes a brand worth checking, the report above says so on its own.
A finalled HVAC permit from 2015 is on record, so the equipment is inside its expected life and we are not pricing a replacement.
- Whether the service is already 200 A. Nothing in the public record says so, and the number is stamped on the main breaker handle.
- Whether the panel can stay where it is. A panel in a closet, over stairs or behind a door has to move, and that alone adds $1,500 to $5,000.
- Whether the service comes in overhead or underground. This is priced as overhead; an underground service with an adequate lateral is a few hundred dollars cheaper, and one with an undersized lateral is thousands more.
Price it for your house — change the assumptions (the panel’s location, the duct, the tonnage, whether the service is overhead or underground) and watch the number move.
Solar potential
The county’s building-footprint layer maps ≈ 1,926 sq ft of roof plan area here. In Tucson a rooftop array produces about 1,645 kWh per installed kW per year (PVWatts), so a typical 6–8 kW home system fits on a fraction of that roof and makes roughly 10,000–13,000 kWh a year. TEP credits exported surplus at its RCP rate — about 5¢/kWh for new applications, locked for 10 years — so sizing to the home’s own use matters more than filling the roof. Already have panels? Check whether they were permitted and finaled.
Flood and drainage
The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.
- FEMA: we did not read the federal flood map for this snapshot. Check FEMA’s flood map for this address ↗
- Local floodplain (the City of Tucson): local floodplain mapping is not reproduced here. A property can sit outside FEMA’s zone and still be inside a locally regulated floodplain, floodway, sheet-flooding area or erosion hazard setback, so check the authority’s own map before planning work. Pima County RFCD flood hazard map for parcel 110102090 ↗ · the City of Tucson ↗
The record behind this read
- Parcel
- 110102090
- Year constructed
- 2001 (county record)
- Permitting authority
- Tucson
- Zoning
- R-2
- Living area
- 2,137 sq ft
- Cooling
- Refrigeration
- Heating
- Forced Air
- Electrical service
- No service or panel permit on record — normal for a house built in 2001, which started at about 200 A. (the era estimate is from the year built, 2001 — not a measurement)
Living area, cooling and heating come from the Pima County Assessor’s file published 28 Jan 2026. Check any row against Pima County’s own parcel record ↗.
What this means for work here
The most recent permit with evidence of issuance is dated 2015. City records show the permit was finalized. The permit covers only the work described in that record.
What that reading rests on. The issuing offices hold 4 building permits for this parcel dated between 2000 and 2015. One trade permit, one pool or spa permit, one new-construction permit and one fence or wall permit. 3 of them carry a final inspection; the other one was issued, expired or is still open, which is not the same as work completed. There is 1 code-enforcement case recorded against the parcel, all of them closed. We do not reproduce complaint text — it routinely names people with no connection to the property.
Go straight to the records
Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.
City permit record (4): 2015 T15CM03808 · 2000 T00BU03292 · 2000 T00CM00889 · 2000 T00BU00112
Code enforcement cases (1): 2010 T10DV07407
Permit records courtesy of the City of Tucson — each link opens the City’s own file. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 110102090.
See an error? Report a correction · About this data.
Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.
In the public record: All homes in 85712 · Homes by ZIP code · Commercial property in 85712 · Permit data by neighborhood
Planning work at this home?
Arizona Electrical Solutions — electrical, HVAC, underground, design-build and general contracting in Tucson (four Arizona ROC licenses). The address, parcel and this report travel with your request.
Want a plain-English brief of this record first?
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
Permanent link: Electrical permit history for 3138 N Placita Agua Caliente (aztucsonelectricalsolutions.com/property/110102090/3138-n-placita-agua-caliente-tucson-az-85712)
Electrical summary — 3138 N Placita Agua Caliente, Tucson, AZ 85712
Parcel 110102090Year built 2001Living area 2,137 sq ftPermit history City of TucsonRecord checked 13 Nov 2026
- Electrical service: no service or panel permit on record — normal for a house built in 2001, which started at about 200 A.
- Watch for: built 2001, before AFCI breakers were required in most rooms.
- Other work on record: heat pump replaced 2015, new-construction permit 2000, fence or wall permit 2000.
Permits on record, newest first
| Date | Permit | Type | Status |
|---|---|---|---|
| Jun 2015 | T15CM03808 | Heating & cooling | Final |
| Feb 2000 | T00CM00889 | New-construction permit | Final |
| Jan 2000 | T00BU00112 | Fence or wall permit | Final |
Voided or withdrawn permit records: 1 (not listed).
Era flags
- Built before 2008: AFCI breakers were not required in most rooms.
Ask the home inspector to check
- The main breaker rating and the panel brand — no service upgrade is on record.
- Open breaker spaces in the panel, and GFCI and AFCI protection where the current code expects it.
Live report: https://www.aztucsonelectricalsolutions.com/property/110102090/3138-n-placita-agua-caliente-tucson-az-85712
How this property compares nearby
Built in 2001 — earlier than about 12% of the 8,300 homes in ZIP 85712. 2,137 sq ft of living area — above this ZIP’s median of 1,430 sq ft. About 29% of homes in this ZIP still cool with evaporative — this one has moved to refrigeration cooling. Properties on N PLACITA AGUA CALIENTE hold 44 City permits on record, 6 of them since 2022.
Counts and years from the same public records.
How this report was built
This is a reading of public records for parcel 110102090 — 4 City permits on file from 2000 to 2015 and 1 code enforcement case — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive. City of Tucson permit records go back to the mid-1990s, with fewer before 2006, when the City’s older paper files were only partly digitized. The construction year, living area, cooling, heating, roof and walls on this page come from our saved copy of the Assessor’s own published data file (dated 28 Jan 2026). The sewer connection file and the flood map were not read for this snapshot. A permit that is absent here may predate the digitized record or sit in a system this snapshot did not read. This record was built 22 Aug 2026 and compared against the City’s 13 Nov 2026 permit export, with no change for this parcel.
What this report is and is not. This is a screening report written by Arizona Electrical Solutions from public records — the year the building went up, how it is classified and what has been permitted. It is not an inspection, an appraisal, a floodplain determination, or engineering, legal or purchasing advice, and nothing in it confirms what is installed at this address: a permit shows what was permitted, a missing permit does not mean nothing was done, and era notes describe what was common when the building went up, not what is in this one. Price figures are estimates, not quotes. The issuing agency’s own record is the official one and controls over anything summarized here — every permit links to it. Only someone looking at the panel can confirm the service size, the panel brand or the wiring.
Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.
Permit history: City of Tucson addresses, back to the mid-1990s. Elsewhere in Pima County: property facts from the Assessor, no permit history yet.