Electrical permit history — 930 E El Caminito Pl

930 E El Caminito Pl, Tucson — built 1959, with 4 permits on record. Review electrical, HVAC and remodel history with links to official records.

Home

930 E El Caminito Pl

Built 1959 — post-war 60–100 A service era · last permitted panel/service work 1999 (finaled)

Parcel
108200630
Built
1959 (county record)
Jurisdiction
Tucson
Zoning
R-2
Assessor use
Sfr Grade 010-3 Urban Subdivided
Parcel size
0.23 acres
Living area
1,092 sq ft (assessor record)
Cooling
Refrigeration (assessor record)
Heating
Forced Air (assessor record)
Roof
Built Up (assessor record)
Garage
Carport (1-car) (assessor record)
Sewer
Connection on file (1959) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)
Typical original service for a 1959 home
approximately 60–100 A
Service on record
City records show the 1999 permit was finalized; the permit description states “UPGRADE:ELECTRIC:60 TO 200AMP” — an increase in capacity as described, not a confirmed installed rating.

See the property

County aerial photograph centered on 930 E El Caminito Pl, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & panelCurrentLast permitted 1999 (27 years ago). Contractor of record: L D J ELECTRIC INC ,. The permit describes an increase in capacity, which is the single best sign the electrical has actually been brought forward. T99EL00092 — UPGRADE:ELECTRIC:60 TO 200AMP
  • Heating & coolingNot in this windowNothing in the permit records we read for this parcel that names this system. The assessor records cooling as Refrigeration and heating as Forced Air. Cooling equipment works harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes.
  • Water heaterNot in this windowNothing in the permit records we read for this parcel that names this system. Water heaters are frequently swapped without a permit, so this line is especially weak evidence either way.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. The assessor records the roof as Built Up.
  • Plumbing work on recordNot in this windowNothing in the permit records we read for this parcel that names this system. Unremarkable — plenty of buildings never need a permitted plumbing repair.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    60–100 A was standard. That is enough for a mid-century house, not for a modern kitchen, HVAC, and an EV. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check — high priority

    Federal Pacific (Stab-Lok) and Zinsco/Sylvania panels were sold through this period. Stab-Lok breakers have a documented history of failing to trip internally; Zinsco breakers can weld to the bus so the handle moves without breaking the circuit. In both cases a replacement breaker does not resolve it — the panel itself is what gets replaced. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    Grounded branch circuits did not become the norm until the early 1960s — much of the original wiring here is likely ungrounded. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    Cloth-jacketed NM cable is common in this era. The jacket embrittles with age and heat, particularly in Tucson attics. The permit record does not confirm this; an on-site inspection is required.

Recorded sales (2)

Recorded transfers from the Pima County Assessor — 2 of 2
DatePriceType
2016-02-26$132,800Warranty Deed
2008-07-11$155,000Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2015-05-27 (T15EX01304) — LOCATION #1-10' X10'X 6' EXCAVATION TO REMOVE EXISTING CLEAN OUT AND REPLACE WITH A NEW TERMINAL MANHOLE. ALL REMOVED SIDEWALK WILL BE REPLACED TO MATCH EXISTING. LOCATION # 2- 10'X10'X6' EXCAVATION TO REMOVE EXISTING CLEAN OUT AND REPLACE WITH A NEW TERMINAL MANHOLE. ALL REMOVED SIDEWALK WILL BE REPLACED TO MATCH EXISTING. WORK ORDER # 150192.

Permit history (4)

Permit history for this parcel — 4 of 4 records
DateRecordWhatStatusValue
2015-05-27finaledT15EX01304City permit recordEXCAVLOCATION #1-10' X10'X 6' EXCAVATION TO REMOVE EXISTING CLEAN OUT AND REPLACE WITH A NEW TERMINAL MANHOLE. ALL REMOVED SIDEWALK WILL BE REPLACED TO MATCH EXISTING. LOCATION # 2- 10'X10'X6' EXCAVATION TO REMOVE EXISTING CLEAN OUT AND REPLACE WITH A NEW TERMINAL MANHOLE. ALL REMOVED SIDEWALK WILL BE REPLACED TO MATCH EXISTING. WORK ORDER # 150192Final
2015-05-27T15TC01301City permit recordBARRICADLOCATION #1-10' X10'X 6' EXCAVATION TO REMOVE EXISTING CLEAN OUT AND REPLACE WITH A NEW TERMINAL MANHOLE. ALL REMOVED SIDEWALK WILL BE REPLACED TO MATCH EXISTING. LOCATION # 2- 10'X10'X6' EXCAVATION TO REMOVE EXISTING CLEAN OUT AND REPLACE WITH A NEW TERMINAL MANHOLE. ALL REMOVED SIDEWALK WILL BE REPLACED TO MATCH EXISTING. WORK ORDER # 150192Expired
2009-12-10finaledT09PL02072City permit recordPLUMBGAS LINE:REPLACE- EXTERIOR LINE ONLY RESFinal
1999-01-14finaledT99EL00092City permit recordELECTUPGRADE:ELECTRIC:60 TO 200AMPFinal

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this home?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 108200630 — 4 permits on file from 1999 to 2015 (1 excav, 1 barricad, 1 plumb, 1 elect) — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.