Electrical permit history — 332 E Navajo Rd

332 E Navajo Rd, Tucson — built 1950, with 5 permits on record. Review electrical, HVAC and remodel history with links to official records.

Home

332 E Navajo Rd

Built 1950 — post-war 60–100 A service era · last permitted panel/service work 2008 (finaled)

Parcel
106042630
Built
1950 (county record)
Jurisdiction
Tucson
Zoning
R-3
Assessor use
Sfr Grade 010-3 Urban Subdivided
Parcel size
0.37 acres
Living area
1,714 sq ft (assessor record)
Cooling
Evaporative (assessor record)
Heating
Wall Furnace (assessor record)
Roof
Prepared Roll (assessor record)
Garage
Carport (1-car) (assessor record)
Sewer
Connection on file (1953) (county sewer connection records)
Flood zone
AE — Special Flood Hazard Area (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)
Typical original service for a 1950 home
approximately 60–100 A
Service on record
City records show the 2008 permit was finalized; the permit description states “UPGRADE: ELECTRIC FROM 100-200 AMP” — an increase in capacity as described, not a confirmed installed rating.

See the property

County aerial photograph centered on 332 E Navajo Rd, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & panelCurrentLast permitted 2008 (18 years ago). City inspection record: ELECTRIC - FINAL approved 2008-08-19. The permit describes an increase in capacity, which is the single best sign the electrical has actually been brought forward. T08EL01458 — UPGRADE: ELECTRIC FROM 100-200 AMP
  • Heating & coolingNot in this windowNothing in the permit records we read for this parcel that names this system. The assessor records cooling as Evaporative and heating as Wall Furnace. Cooling equipment works harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes.
  • Water heaterNot in this windowNothing in the permit records we read for this parcel that names this system. Water heaters are frequently swapped without a permit, so this line is especially weak evidence either way.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. The assessor records the roof as Prepared Roll.
  • Plumbing work on recordNot in this windowNothing in the permit records we read for this parcel that names this system. Unremarkable — plenty of buildings never need a permitted plumbing repair.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    60–100 A was standard. That is enough for a mid-century house, not for a modern kitchen, HVAC, and an EV. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check — high priority

    Federal Pacific (Stab-Lok) and Zinsco/Sylvania panels were sold through this period. Stab-Lok breakers have a documented history of failing to trip internally; Zinsco breakers can weld to the bus so the handle moves without breaking the circuit. In both cases a replacement breaker does not resolve it — the panel itself is what gets replaced. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    Grounded branch circuits did not become the norm until the early 1960s — much of the original wiring here is likely ungrounded. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    Cloth-jacketed NM cable is common in this era. The jacket embrittles with age and heat, particularly in Tucson attics. The permit record does not confirm this; an on-site inspection is required.

Most recent permit on record for this parcel: 2026-07-10 (TR-ROW-0726-00805) — The Amphi Neighborhood Painting Party will close down the intersection of Navajo Rd. and Fontana Ave., bringing together local neighbors to install city approved traffic calming measures in the form of bollards, planters, plants, and painting to both make their streets safer and beautify their living space. Using a traffic control plan provided by Desert Barricades, we will close down the intersection to cars so people of all ages can plants the plants and paint the street. The event will run 7am to 1pm on September 5th, 2026. Traffic control set up and take down: 5am - 1:30pm.

Permit history (5)

Permit history for this parcel — 5 of 5 records
DateRecordWhatStatusValue
2026-07-10TR-ROW-0726-00805City permit recordPool / spaThe Amphi Neighborhood Painting Party will close down the intersection of Navajo Rd. and Fontana Ave., bringing together local neighbors to install city approved traffic calming measures in the form of bollards, planters, plants, and painting to both make their streets safer and beautify their living space. Using a traffic control plan provided by Desert Barricades, we will close down the intersection to cars so people of all ages can plants the plants and paint the street. The event will run 7am to 1pm on September 5th, 2026. Traffic control set up and take down: 5am - 1:30pmApproved
2025-10-02TC-RES-1025-04846City permit recordTrade permitVOID: Wrong Permit Type. This work should be completed as a Residential Trade permit. There is an existing Residential Trade permit TC-RES-1025-04848 for this same scope of work. Please continue with Trade permit TC-RES-1025-04848. This permit will be voided. New 200amp panel installVoid
2025-10-02expired 2026-04-07TC-RES-1025-04848City permit recordResidential Building - One or Two FamilyNew 200amp panel installInspections
2022-02-24finaledT22RW00658City permit recordROW5X5 BELL HOLE IN ASPHALT & 30' TRENCH THRU ASPHALT ACROSS NAVAJO RD TO REPLACE GAS LINE . CREWS MAY BE WORKING SATURDAYS FROM 7:00 AM TO 3:30 PM. PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. PAVEMENT PATCH TYPE SHALL BE IN CONFORMANCE TO THE CURRENT EDITION OF THE CITY OF TUCSON PUBLIC UTILITY ADMINISTRATIVE MANUAL. IN THE EVENT THAT WEEKEND OR AFTER-HOURS WORK IS INTENDED, CONTACT COT INSPECTION STAFF. DAN ROBERTSON AT 520-400-6722 OR TOM ADKINS AT 520-400-3813. OTHER ACTIVITIES IN THE AREA, WILL NEED TO COORDINATE TRAFFIC CONTROL SETUP WITH EXISTING SETUP.Final
2008-08-05finaledT08EL01458City permit recordELECTUPGRADE: ELECTRIC FROM 100-200 AMPFinal

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this home?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 106042630 — 5 permits on file from 2008 to 2026 (1 pool / spa, 1 trade permit, 1 residential building - one or two family, 1 row) — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.