Electrical permit history — 2256 W Frostwood Ln
2256 W Frostwood Ln
- Electrical service: no service or panel permit on record — normal for a house built in 2001, which started at about 200 A.
- Watch for: built 2001, before AFCI breakers were required in most rooms.
- Other work on record: AC replacement permitted 2026 (permit not closed), new-construction permit 2001.
From City of Tucson permits and the Pima County Assessor, checked 13 Nov 2026. Not an inspection.
The permanent link and the summary above, sent once. No list.One email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list.
Is it time to upgrade?
Probably not: no service work is on record, which is normal for a house built in 2001.
- Electrical service & panelLooks currentNo service or panel permit on record — normal for a house built in 2001, which started at about 200 A.
- Heating & coolingWorth checkingA 2026 permit covers this work, but the record shows no final inspection (official status: Issued). The assessor records cooling as Refrigeration and heating as Forced Air (assessor characteristics can lag permitted work). TC-RES-0826-04378 — *URGENT/EMERGENCY NEED* Customer elected to have HVAC system replaced as opposed to repairing existing system. Replacement of existing system "like for like". Remove existing HVAC system and replace with: 3.5 TON 80% 14SEER SPLIT GAS 14.0+ SEER2 Single Stage Compressor Single Stage, Multi-SpeedECM 80% Gas Furnace All Aluminum Evaporator Coil (Extended Life)
- Water heaterWorth checkingNo permit on record names this system. Water heaters are frequently swapped without a permit, so this line is especially weak evidence either way.
- RoofWorth checkingNo permit on record names this system. The assessor records the roof as Tile.
What that usually means electrically
- Era-based check
AFCI protection did not enter the code until the 1999 NEC (bedroom circuits, effective 2002) and was not expanded to most living areas until 2008 — so houses from the earlier part of this range typically have none at all.
- Era-based check
200 A is typical and is usually adequate — worth confirming the panel has physical space before planning new loads.
What to check at the panel
These are the things only someone standing at the panel can settle — about a minute’s work.
- The number stamped on the main breaker handle — 100, 125, 150, 175 or 200. That is the service rating, and no record on this page confirms it.
- The busbar rating printed on the panel label. It is a different number from the main breaker, and it is the one that decides how much solar a panel can take under the 120% rule.
- The manufacturer and catalog number on the label inside the door.
- How many full-size spaces are left, how many positions the label permits a tandem breaker in, and the tandem limit the label states. A full panel is a different job from a full service.
- The conductor material at the main lugs, and whether the terminations look clean and tight.
- Whether there is a separate meter-main outside as well as the panel indoors — that changes where a disconnect and any new feeder would land.
- Whether the water heater, dryer and range are gas or electric. No public record carries fuel type, and it is the single biggest variable in a load calculation — it can move the calculated load on the same house by more than 40 A.
With those in hand you can run the numbers yourself. The load calculator does the NEC 220.82 optional-method calculation — the same method a permit application uses — and shows its work. It offers to start from the 1,176 sq ft on the assessor record; every other value is yours to enter. Open the load calculator
What these jobs cost here
Estimated ranges for this property, from its age, its size and the Tucson permit fee and code.
Electrical panel or service upgrade Estimate
$3,800
Most jobs like this land between $3,400 and $4,700.
The bottom of this range is a clean, simple job: single storey, framed wall, the panel staying where it is, a short service run, and nothing unexpected once the cover comes off. That job is real and we do book it — but it is the best case, not the average, and the figure above it is what most houses actually come to.
Priced from built 2001 (200 A, pre-2008 AFCI-code era); City of Tucson permit fee and the 2023 NEC it has adopted.
Priced with Tucson Electric Power’s charges — TEP serves the City of Tucson. The assessor records framed walls, so no masonry drilling or stucco patch is priced.
What would move this price
- Only if the panel has to move — a clothes closet, a bathroom, over a stairway, or behind a door +$3,900
If every one of those turned out to apply, this becomes about $8,600. That is the worst realistic case.
- A service upgrade fixes capacity and the safety of the service equipment. It does not fix branch wiring. If the reason you are here is flickering lights, warm outlets or cloth-jacketed wiring, an upgrade is a down payment on a much bigger problem, and it is worth knowing that before you spend in the wrong order.
- You may not need the upgrade at all. NEC 220.87 lets an existing dwelling be sized from twelve months of actual metered demand rather than a calculated load, and real houses draw far less than the calculation predicts. Ask your utility for a year of interval data and have it run that way first. Two cautions so this does not backfire: the demand tile in a TEP online account shows on-peak demand only, which is not the annual maximum the code asks for — you want the formal usage-data release — and 220.87 proves CAPACITY and nothing else. It does not create empty breaker spaces, and it does not make an obsolete panel, or one whose breakers have a documented failure history, safe. Those are separate questions with separate answers — and where the era makes a brand worth checking, the report above says so on its own.
Air conditioning or heat pump replacement Estimate
$14,100
Most jobs like this land between $11,100 and $17,800.
Priced from a 3.5-ton split air conditioner with gas furnace on the 2026 permit TC-RES-0826-04378 (issued — completion not confirmed), so the replacement is priced like for like; cooling on the assessor record reads “Refrigeration”; City of Tucson permit fee.
What would move this price
- Only if the duct has to be replaced — no record carries its condition, and on an attic system at this age it is a real possibility +$5,400
If every one of those turned out to apply, this becomes about $23,300. That is the worst realistic case.
- Because a permit names the size, this is priced at that size rather than from floor area. Worth asking whether that size was ever right: a Manual J often comes out smaller, and a correctly sized machine costs less and behaves better in the monsoon.
- If someone quotes you “just the outside unit” on a system installed between about 2010 and 2024, stop. New condensers use R-454B or R-32; an R-410A indoor coil cannot be matched to one unless the manufacturer publishes that exact combination with a mitigation kit. The honest options are to find remaining pre-2025 R-410A stock — still legal to install, but scarce, and it still has to meet the Arizona efficiency floor — or to replace both halves as a matched system.
- If you are told a heat pump means you need a 200 A service, ask which load. It is almost never the compressor — a 5-ton outdoor unit is about a 31 A circuit. It is the electric BACKUP HEAT STRIP, which on a large kit can be a 109 A circuit on its own. In Tucson's mild heating season the strip kit can often be sized far smaller, or left out, and the service question disappears with it.
- Equipment here lasts ten to fourteen years, not the fifteen to twenty you will read nationally — a rooftop package unit at the short end. Replace rather than repair if the unit is twelve or more and the repair is over $1,500, if the compressor has failed and it is eight or more, or if the repair is over 40% of a new system.
- Whether the service is already 200 A. Nothing in the public record says so, and the number is stamped on the main breaker handle.
- Whether the panel can stay where it is. A panel in a closet, over stairs or behind a door has to move, and that alone adds $1,500 to $5,000.
- Whether the service comes in overhead or underground. This is priced as overhead; an underground service with an adequate lateral is a few hundred dollars cheaper, and one with an undersized lateral is thousands more.
- The duct. No record carries its condition, and on a Tucson house with duct in an unconditioned attic it is often worth more than a bigger machine.
- Whether that floor area is all conditioned space. An assessor figure can include a garage, an enclosed porch or an addition that was never cooled, and every square foot of that oversizes the equipment this page priced.
Price it for your house — change the assumptions (the panel’s location, the duct, the tonnage, whether the service is overhead or underground) and watch the number move.
Solar potential
The county’s building-footprint layer maps ≈ 2,175 sq ft of roof plan area here. In Tucson a rooftop array produces about 1,645 kWh per installed kW per year (PVWatts), so a typical 6–8 kW home system fits on a fraction of that roof and makes roughly 10,000–13,000 kWh a year. TEP credits exported surplus at its RCP rate — about 5¢/kWh for new applications, locked for 10 years — so sizing to the home’s own use matters more than filling the roof. Already have panels? Check whether they were permitted and finaled.
Flood and drainage
The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.
- FEMA: we did not read the federal flood map for this snapshot. Check FEMA’s flood map for this address ↗
- Local floodplain (the City of Tucson): local floodplain mapping is not reproduced here. A property can sit outside FEMA’s zone and still be inside a locally regulated floodplain, floodway, sheet-flooding area or erosion hazard setback, so check the authority’s own map before planning work. Pima County RFCD flood hazard map for parcel 103216400 ↗ · the City of Tucson ↗
The record behind this read
- Parcel
- 103216400
- Year constructed
- 2001 (county record)
- Permitting authority
- Tucson
- Zoning
- R-1
- Living area
- 1,176 sq ft
- Cooling
- Refrigeration
- Heating
- Forced Air
- Electrical service
- No service or panel permit on record — normal for a house built in 2001, which started at about 200 A. (the era estimate is from the year built, 2001 — not a measurement)
Living area, cooling and heating come from the Pima County Assessor’s file published 28 Jan 2026. Check any row against Pima County’s own parcel record ↗.
What this means for work here
The most recent permit with evidence of issuance is dated 2026. The work was permitted, but final completion is not confirmed. The permit covers only the work described in that record.
What that reading rests on. The issuing offices hold 2 building permits for this parcel dated between 2001 and 2026. One trade permit and one new-construction permit. 1 of them carries a final inspection; the other one was issued, expired or is still open, which is not the same as work completed.
Go straight to the records
Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.
Residential building (1): 2026 TC-RES-0826-04378
City permit record (1): 2001 T01CM04856
Permit records courtesy of the City of Tucson — each link opens the City’s own file. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 103216400.
See an error? Report a correction · About this data.
Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.
In the public record: All homes in 85745 · Homes by ZIP code · Commercial property in 85745 · Permit data by neighborhood
Planning work at this home?
Arizona Electrical Solutions — electrical, HVAC, underground, design-build and general contracting in Tucson (four Arizona ROC licenses). The address, parcel and this report travel with your request.
Want a plain-English brief of this record first?
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
Permanent link: Electrical permit history for 2256 W Frostwood Ln (aztucsonelectricalsolutions.com/property/103216400/2256-w-frostwood-ln-tucson-az-85745)
Electrical summary — 2256 W Frostwood Ln, Tucson, AZ 85745
Parcel 103216400Year built 2001Living area 1,176 sq ftPermit history City of TucsonRecord checked 13 Nov 2026
- Electrical service: no service or panel permit on record — normal for a house built in 2001, which started at about 200 A.
- Watch for: built 2001, before AFCI breakers were required in most rooms.
- Other work on record: AC replacement permitted 2026 (permit not closed), new-construction permit 2001.
Permits on record, newest first
| Date | Permit | Type | Status |
|---|---|---|---|
| Oct 2026 | TC-RES-0826-04378 | Heating & cooling | Open |
| Oct 2001 | T01CM04856 | New-construction permit | Final |
Era flags
- Built before 2008: AFCI breakers were not required in most rooms.
Ask the home inspector to check
- Whether the 2026 heating and cooling permit was finished — the City shows no final inspection.
- The main breaker rating and the panel brand — no service upgrade is on record.
Live report: https://www.aztucsonelectricalsolutions.com/property/103216400/2256-w-frostwood-ln-tucson-az-85745
How this property compares nearby
Built in 2001 — earlier than about 18% of the 12,496 homes in ZIP 85745. 1,176 sq ft of living area — below this ZIP’s median of 1,696 sq ft. About 22% of homes in this ZIP still cool with evaporative — this one has moved to refrigeration cooling. Properties on W FROSTWOOD LN hold 63 City permits on record, 11 of them since 2022.
Counts and years from the same public records.
How this report was built
This is a reading of public records for parcel 103216400 — 2 City permits on file from 2001 to 2026 — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive. City of Tucson permit records go back to the mid-1990s, with fewer before 2006, when the City’s older paper files were only partly digitized. The construction year, living area, cooling, heating, roof and walls on this page come from our saved copy of the Assessor’s own published data file (dated 28 Jan 2026). The sewer connection file and the flood map were not read for this snapshot. A permit that is absent here may predate the digitized record or sit in a system this snapshot did not read. This record was built 13 Nov 2026 from the City’s permit export of that day.
What this report is and is not. This is a screening report written by Arizona Electrical Solutions from public records — the year the building went up, how it is classified and what has been permitted. It is not an inspection, an appraisal, a floodplain determination, or engineering, legal or purchasing advice, and nothing in it confirms what is installed at this address: a permit shows what was permitted, a missing permit does not mean nothing was done, and era notes describe what was common when the building went up, not what is in this one. Price figures are estimates, not quotes. The issuing agency’s own record is the official one and controls over anything summarized here — every permit links to it. Only someone looking at the panel can confirm the service size, the panel brand or the wiring.
Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.
Permit history: City of Tucson addresses, back to the mid-1990s. Elsewhere in Pima County: property facts from the Assessor, no permit history yet.