Property overview — 3318 W Calle De Manzanillo

3318 W Calle De Manzanillo

  • Electrical service: county permits weren’t checked for this address. A 2004 house typically started with about 200 A service.
  • Watch for: built 2004, before AFCI breakers were required in most rooms.
  • Other work on record: not checked.

From the Pima County Assessor; county permits weren’t checked. Record checked 13 Nov 2026. Not an inspection.

I am a
Get a free panel check

Is it time to upgrade?

Can’t tell yet: county permits weren’t checked for this address.

  • Electrical service & panelNot checkedCounty permits weren’t checked for this address. A 2004 house typically started with about 200 A service.
  • Heating & coolingNot checkedThe assessor records cooling as Refrigeration and heating as Forced Air. Cooling equipment works harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes.
  • Water heaterNot checked
  • RoofNot checkedThe assessor records the roof as Asphalt.

What that usually means electrically

  • Era-based check

    AFCI protection did not enter the code until the 1999 NEC (bedroom circuits, effective 2002) and was not expanded to most living areas until 2008 — so houses from the earlier part of this range typically have none at all.

  • Era-based check

    200 A is typical and is usually adequate — worth confirming the panel has physical space before planning new loads.

What to check at the panel

These are the things only someone standing at the panel can settle — about a minute’s work.

  1. The number stamped on the main breaker handle — 100, 125, 150, 175 or 200. That is the service rating, and no record on this page confirms it.
  2. The busbar rating printed on the panel label. It is a different number from the main breaker, and it is the one that decides how much solar a panel can take under the 120% rule.
  3. The manufacturer and catalog number on the label inside the door.
  4. How many full-size spaces are left, how many positions the label permits a tandem breaker in, and the tandem limit the label states. A full panel is a different job from a full service.
  5. The conductor material at the main lugs, and whether the terminations look clean and tight.
  6. Whether there is a separate meter-main outside as well as the panel indoors — that changes where a disconnect and any new feeder would land.
  7. Whether the water heater, dryer and range are gas or electric. No public record carries fuel type, and it is the single biggest variable in a load calculation — it can move the calculated load on the same house by more than 40 A.

With those in hand you can run the numbers yourself. The load calculator does the NEC 220.82 optional-method calculation — the same method a permit application uses — and shows its work. It offers to start from the 1,004 sq ft on the assessor record; every other value is yours to enter. Open the load calculator

What these jobs cost here

Estimated ranges for this property, from its age, its size and the unincorporated Pima County permit fee and code.

Electrical panel or service upgrade Estimate

$3,700

Most jobs like this land between $3,400 and $4,700.

The bottom of this range is a clean, simple job: single storey, framed wall, the panel staying where it is, a short service run, and nothing unexpected once the cover comes off. That job is real and we do book it — but it is the best case, not the average, and the figure above it is what most houses actually come to.

Priced from built 2004 (200 A, pre-2008 AFCI-code era); Pima County permit fee and the 2023 NEC it has adopted.

Priced with Tucson Electric Power’s charges. This area is served by both TEP and Trico and no public map settles it per address — check a recent bill or the label on the meter. The assessor records framed walls, so no masonry drilling or stucco patch is priced.

What would move this price
  • Only if the panel has to move — a clothes closet, a bathroom, over a stairway, or behind a door +$3,900

If every one of those turned out to apply, this becomes about $8,500. That is the worst realistic case.

Before you spend anything
  • A service upgrade fixes capacity and the safety of the service equipment. It does not fix branch wiring. If the reason you are here is flickering lights, warm outlets or cloth-jacketed wiring, an upgrade is a down payment on a much bigger problem, and it is worth knowing that before you spend in the wrong order.
  • You may not need the upgrade at all. NEC 220.87 lets an existing dwelling be sized from twelve months of actual metered demand rather than a calculated load, and real houses draw far less than the calculation predicts. Ask your utility for a year of interval data and have it run that way first. Two cautions so this does not backfire: the demand tile in a TEP online account shows on-peak demand only, which is not the annual maximum the code asks for — you want the formal usage-data release — and 220.87 proves CAPACITY and nothing else. It does not create empty breaker spaces, and it does not make an obsolete panel, or one whose breakers have a documented failure history, safe. Those are separate questions with separate answers — and where the era makes a brand worth checking, the report above says so on its own.

Air conditioning or heat pump replacement Estimate

$12,800

Most jobs like this land between $10,200 and $15,900.

Priced from 1,004 sq ft → about 2 tons, the size most Tucson quotes start from (about one ton per 500 sq ft); cooling on the assessor record reads “Refrigeration”; Pima County permit fee.

Priced for a one-story home. The assessor records an asphalt roof, so no foam re-coating is priced.

What would move this price
  • Only if the duct has to be replaced — no record carries its condition, and on an attic system at this age it is a real possibility +$4,600
  • Only if it is a foam or built-up roof that has to be re-coated at the patch +$900

If every one of those turned out to apply, this becomes about $21,400. That is the worst realistic case.

  • Most Tucson houses carry a packaged unit on the roof, and how easy that roof is to reach is worth more than a thousand dollars of difference on the same equipment.
Before you spend anything
  • If you are told a heat pump means you need a 200 A service, ask which load. It is almost never the compressor — a 5-ton outdoor unit is about a 31 A circuit. It is the electric BACKUP HEAT STRIP, which on a large kit can be a 109 A circuit on its own. In Tucson's mild heating season the strip kit can often be sized far smaller, or left out, and the service question disappears with it.
  • Equipment here lasts ten to fourteen years, not the fifteen to twenty you will read nationally — a rooftop package unit at the short end. Replace rather than repair if the unit is twelve or more and the repair is over $1,500, if the compressor has failed and it is eight or more, or if the repair is over 40% of a new system.
  • Most Tucson quotes size the unit at about one ton per 500 sq ft. A Manual J load calculation often comes out smaller, which means cheaper equipment and a unit that runs long enough to dry the air in the monsoon. Ask for the Manual J before you accept the tonnage.
What the record cannot tell us
  • Whether the service is already 200 A. County permits weren’t checked for this address, and the number is stamped on the main breaker handle.
  • Whether the panel can stay where it is. A panel in a closet, over stairs or behind a door has to move, and that alone adds $1,500 to $5,000.
  • Whether the service comes in overhead or underground. This is priced as overhead; an underground service with an adequate lateral is a few hundred dollars cheaper, and one with an undersized lateral is thousands more.
  • The duct. No record carries its condition, and on a Tucson house with duct in an unconditioned attic it is often worth more than a bigger machine.
  • Whether that floor area is all conditioned space. An assessor figure can include a garage, an enclosed porch or an addition that was never cooled, and every square foot of that oversizes the equipment this page priced.

Price it for your house — change the assumptions (the panel’s location, the duct, the tonnage, whether the service is overhead or underground) and watch the number move.

Solar potential

The county’s building-footprint layer maps ≈ 1,513 sq ft of roof plan area here. In Tucson a rooftop array produces about 1,645 kWh per installed kW per year (PVWatts), so a typical 6–8 kW home system fits on a fraction of that roof and makes roughly 10,000–13,000 kWh a year. What exported surplus earns depends on who serves the meter: TEP credits it at its RCP rate (about 5¢/kWh for new applications, locked for 10 years); Trico Electric Cooperative sets its own rate for members. Either way, sizing to the home’s own use matters more than filling the roof. Already have panels? Check whether they were permitted and finaled.

Flood and drainage

The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; Pima County Regional Flood Control District regulates against its own, and that is the one a permit here is judged against.

The record behind this read

Parcel
225300880
Year constructed
2004 (assessor record — effective construction year, which can move after a major remodel)
Permitting authority
Unincorporated Pima County
Zoning
CR-5
Living area
1,004 sq ft
Cooling
Refrigeration
Heating
Forced Air
Electrical service
County permits weren’t checked for this address. A 2004 house typically started with about 200 A service. (the era estimate is from the year built, 2004 — not a measurement)

Living area, cooling and heating come from the Pima County Assessor’s file published 28 Jan 2026. Check any row against Pima County’s own parcel record ↗.

County permits weren’t checked for this address. Unincorporated Pima County issues its own building permits through Pima County Development Services; this report reads the City of Tucson’s file only. A records request to the county is the authoritative check.

See an error? Report a correction · About this data.

Utility and upgrade pathElectric service out here is split: Trico Electric Cooperative serves much of unincorporated Pima County, Tucson Electric Power serves the rest, and a few areas sit on other systems. The meter release, clearances and point of attachment for an upgrade come from whichever utility serves the meter — check a recent bill or the meter label. See TEP new-service requirements for the TEP side.

In the public record: All homes in 85742 · Homes by ZIP code · Commercial property in 85742 · Permit data by neighborhood

Planning work at this home?

Arizona Electrical Solutions — electrical, HVAC, underground, design-build and general contracting in Tucson (four Arizona ROC licenses). The address, parcel and this report travel with your request.

Get a free panel check

Want a plain-English brief of this record first?

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this property compares nearby

Built in 2004 — earlier than about 29% of the 12,600 homes in ZIP 85742. 1,004 sq ft of living area — below this ZIP’s median of 1,853 sq ft. About 7% of homes in this ZIP still cool with evaporative — this one has moved to refrigeration cooling.

Counts and years from the same public records.

How this report was built

This is a reading of public records for parcel 225300880 — no City of Tucson permits on file — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive. City of Tucson permit records go back to the mid-1990s, with fewer before 2006, when the City’s older paper files were only partly digitized. County permits weren’t checked for this address — unincorporated Pima County issues its own through Pima County Development Services. The construction year, living area, cooling, heating, roof and walls on this page come from our saved copy of the Assessor’s own published data file (dated 28 Jan 2026). The sewer connection file and the flood map were not read for this snapshot. A permit that is absent here may predate the digitized record or sit in a system this snapshot did not read. This record was built 22 Aug 2026 and compared against the City’s 13 Nov 2026 permit export, with no change for this parcel.

What this report is and is not. This is a screening report written by Arizona Electrical Solutions from public records — the year the building went up, how it is classified and what has been permitted. It is not an inspection, an appraisal, a floodplain determination, or engineering, legal or purchasing advice, and nothing in it confirms what is installed at this address: a permit shows what was permitted, a missing permit does not mean nothing was done, and era notes describe what was common when the building went up, not what is in this one. Price figures are estimates, not quotes. The issuing agency’s own record is the official one and controls over anything summarized here — every permit links to it. Only someone looking at the panel can confirm the service size, the panel brand or the wiring.

Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.