Built 1982 — FPE/Zinsco panel era · 12 permits on record; no permitted panel/service or HVAC work among them

Parcel
222210510
Built
1982 (assessor record — effective construction year, which can move after a major remodel)
Jurisdiction
Unincorporated Pima County
Zoning
CMH-2
Assessor use
Sfr With Affixed Mfd Home
Parcel size
1.10 acres
Living area
540 sq ft (assessor record)
Cooling
Evaporative (assessor record)
Heating
Other (assessor record)
Roof
Prepared Roll (assessor record)
Garage
Garage (2-car) (assessor record)
Sewer
No connection on file (sewer or septic status not confirmed by the record — verify on site)
Flood zone
X — minimal flood hazard (FEMA)
Typical original service for a 1982 home
approximately 100–150 A

See the property

County aerial photograph centered on 3340 E Lamb Dr, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & panelNot in this windowNothing in the permit records we read for this parcel that names this system. That does not tell you the service is original — only that nothing has been permitted here recently. The build year is the better clue, and it is above.
  • Heating & coolingNot in this windowNothing in the permit records we read for this parcel that names this system. The assessor records cooling as Evaporative and heating as Other. Cooling equipment works harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes.
  • Water heaterNot in this windowNothing in the permit records we read for this parcel that names this system. Water heaters are frequently swapped without a permit, so this line is especially weak evidence either way.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. The assessor records the roof as Prepared Roll.
  • Plumbing work on recordNot in this windowNothing in the permit records we read for this parcel that names this system. Unremarkable — plenty of buildings never need a permitted plumbing repair.

A found permit means a lot. A missing one means less. This parcel is in unincorporated Pima County, so we read the county’s own permit system — including its historical permits, which reach back into the 1990s where they exist. Every record links to the county’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Federal Pacific Stab-Lok and Zinsco/Sylvania panels were still being installed into the 1980s. Both have documented failure-to-trip histories, by different routes: Stab-Lok breakers fail internally — the trip mechanism jams or sits out of calibration — while Zinsco breakers can weld to the bus, so the handle moves but the circuit stays live. Neither is fixed by a replacement breaker, which is why the panel is what gets replaced. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    100–150 A was typical. Workable for the original house, tight once you add EV charging or electric heat. The permit record does not confirm this; an on-site inspection is required.

Recorded sales (2)

Recorded transfers from the Pima County Assessor — 2 of 2
DatePriceType
2023-07-28$300,000Warranty Deed
2004-05-06$106,000Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2016-04-18 (P16BP02489) — Fence.

Permit history (12)

Permit history for this parcel — 8 of 12 records
DateRecordWhatStatusValue
2016-04-18finaledP16BP02489Pima County permitFence / wallFenceFinal
2012-03-21finaledP12CP01653Pima County permitElectrical / mechanicalCOMBO/MECH -Final
2010-04-09finaledP10CP02127Pima County permitElectrical / mechanicalCOMBO/MECH -Final
2009-09-24finaledP09CP05689Pima County permitElectrical / mechanicalCOMBO/MECH -Final
2008-11-10P08CP08136Pima County permitFence / wallWALL/FEN/FNCE -Application Expired
2008-11-05finaledP08CP08045Pima County permitHistoricalCOMBO/SOTH -Final
2008-10-10finaledP08CP07511Pima County permitHistoricalELECT/SOTH -Final
2008-07-02finaledP08CP04995Pima County permitFence / wallWALL/FEN/FNCE -Final
Show 4 older records
Permit history for this parcel — remaining 4 records
DateRecordWhatStatusValue
2004-05-28finaledP04CP06226Pima County permitHistoricalCOMBO/SADD -Final
2004-05-26P04CP06047Pima County permitHistoricalCOMBO/SADD -Withdrawn
1998-06-17DEQ-006990Pima County permitSepticSEPTHIST/ -CA Issued
1987-07-089345Pima County permitHistoricalPMSHIST/ -Expired

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Record numbers link to the issuing office’s official file — Pima County’s portal for county permits, the City of Tucson’s for city records. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this home?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 222210510 — 12 permits on file from 1987 to 2016 (5 historical, 3 fence / wall, 3 electrical / mechanical, 1 septic) — assembled from the Pima County parcel file, the City of Tucson GIS layers, and Pima County’s Accela permit portal (searched by parcel and by address, because the county’s parcel links break on older records). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.