Electrical permit history — 13841 N Como Dr
13841 N Como Dr, Tucson — with 19 permits on record. Review electrical, HVAC and remodel history with links to official records.
Home
13841 N Como Dr
Build year not published — permits on file from 1987 · 19 permits on record; no permitted panel/service or HVAC work among them
Permanent link: Electrical permit history for 13841 N Como Dr (aztucsonelectricalsolutions.com/property/21914006a/13841-n-como-dr-tucson-az-85755) · Public records last checked 2026-08-18
- Parcel
- 21914006A
- Built
- 1987 (earliest permit on file)
- Jurisdiction
- Unincorporated Pima County
- Zoning
- RH
- Assessor use
- Sfr Dominant + Additional Rural Non-Subdiv
- Parcel size
- 2.47 acres
- Sewer
- No connection on file (sewer or septic status not confirmed by the record — verify on site)
- Flood zone
- AE — Special Flood Hazard Area (FEMA)
- Typical original service for a 1987 home
- approximately 100–150 A
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Flood and drainage — two different maps
The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map. Pima County’s Regional Flood Control District regulate against their own, and that is the one a permit here is judged against.
FEMA National Flood Hazard Layer — zones and base-flood-elevation contours. Federal insurance mapping. Open this property on FEMA’s official flood map ↗
Pima County RFCD local floodplains, floodways, sheet-flooding and erosion hazard areas. This is the map local floodplain regulation uses.
Parcel outlined in yellow. Both maps are drawn live from the agencies’ own map services at the same extent, so you can compare them directly. They are context for planning, not a floodplain determination — for that, ask the floodplain administrator for the jurisdiction shown below.
- FEMA: FEMA flood zone AE — Special Flood Hazard Area (1% annual chance flood); floodplain rules and elevation requirements typically apply to new exterior equipment and structures. FIRM panel 04019C1060L, effective 2011-06-16.
- Pima County RFCD: Pima County maps this location inside a special-studies floodplain delineation on Canada Agua Wash. County floodplain regulation applies here whatever the FEMA map shows — the two are separate maps with separate rules.
- Base flood elevation: the county maps 3 BFE contours near this parcel, 2940–2960 ft NAVD88. Those are contour lines near the property, not an elevation certified for this site.
- Map revised: FEMA’s map here was amended by a Letter of Map Revision (case 22-09-1051p) on 2024-10-02, so a printed FIRM panel may be out of date here.
- City of Tucson: its flood-hazard mapping covers City limits only and does not apply to this parcel. The jurisdiction above is the one to ask.
Is it time to upgrade?
- Electrical service & panelNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2017 addition / alteration permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not tell you the service is original — only that nothing has been permitted here recently. The build year is the better clue, and it is above.
- Heating & coolingNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2017 addition / alteration permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Cooling equipment works harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes.
- Water heaterNot in this windowNothing in the permit records we read for this parcel that names this system. Water heaters are frequently swapped without a permit, so this line is especially weak evidence either way.
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system.
- Plumbing work on recordNot in this windowNothing in the permit records we read for this parcel that names this system. Unremarkable — plenty of buildings never need a permitted plumbing repair.
A found permit means a lot. A missing one means less. This parcel is in unincorporated Pima County, so we read the county’s own permit system — including its historical permits, which reach back into the 1990s where they exist. Every record links to the county’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check — high priority
Federal Pacific Stab-Lok and Zinsco/Sylvania panels were still being installed into the 1980s. Both have documented failure-to-trip histories, by different routes: Stab-Lok breakers fail internally — the trip mechanism jams or sits out of calibration — while Zinsco breakers can weld to the bus, so the handle moves but the circuit stays live. Neither is fixed by a replacement breaker, which is why the panel is what gets replaced. The permit record does not confirm this; an on-site inspection is required.
- Era-based check
100–150 A was typical. Workable for the original house, tight once you add EV charging or electric heat. The permit record does not confirm this; an on-site inspection is required.
- Worth confirming
A pool or spa was permitted in 2015. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.
Most recent permit on record for this parcel: 2022-04-08 (P22BP03994) — Electrical Equipment.
Permit history (19)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2022-04-08finaled | P22BP03994Pima County permit | Electrical / mechanicalElectrical Equipment | Final | |
| 2022-03-25 | P22BP03297Pima County permit | Addition / alterationSingle Family Residence Addition | Permit Expired | |
| 2018-12-27 | P18BP08935Pima County permit | Electrical / mechanicalMechanical/Plumbing Equipment | Permit Expired | |
| 2017-05-16 | P17BP01405-01Pima County permit | Addition / alterationSingle Family Residence Addition - Revision | Approved | |
| 2017-03-02finaled | P17BP01405Pima County permit | Addition / alterationSingle Family Residence Addition | Final | |
| 2017-01-12 | P16BP05567-01Pima County permit | Addition / alterationSingle Family Residence Addition - Revision | Approved | |
| 2016-10-10 | P16FC00526Pima County permit | Floodplain UseSOL, ADD | Issued | |
| 2016-10-07finaled | P16BP06229Pima County permit | Electrical / mechanicalElectrical Equipment | Final |
Show 11 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2016-09-07finaled | P16BP05567Pima County permit | Addition / alterationSingle Family Residence Addition | Final | |
| 2015-10-07 | P15FC00414Pima County permit | Floodplain UseSPS | Issued | |
| 2015-10-07finaled | P15BP06672Pima County permit | Pool / spaResidential Pool/Spa | Final | |
| 2008-05-16finaled | P08CP03596Pima County permit | HistoricalCOMBO/SNEW - | Final | |
| 2008-05-16finaled | P08CP03600Pima County permit | HistoricalCOMBO/SADD - | Final | |
| 1998-04-30 | DEQ-003861Pima County permit | SepticSEPTHIST/ - | CA Issued | |
| 1992-03-18 | 58829Pima County permit | HistoricalPMSHIST/ - | Expired | |
| 1988-10-06 | 25568Pima County permit | HistoricalPMSHIST/ - | Expired | |
| 1988-09-26 | 25261Pima County permit | HistoricalPMSHIST/ - | Expired | |
| 1988-01-19 | 16373Pima County permit | HistoricalPMSHIST/ - | Expired | |
| 1987-11-12finaled | 14291Pima County permit | HistoricalPMSHIST/ - | Final |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Record numbers link to the issuing office’s official file — Pima County’s portal for county permits, the City of Tucson’s for city records. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Utility and upgrade pathElectric service out here is split: Trico Electric Cooperative serves much of unincorporated Pima County, Tucson Electric Power serves the rest, and a few areas sit on other systems. The meter release, clearances and point of attachment for an upgrade come from whichever utility serves the meter — check a recent bill or the meter label. See TEP new-service requirements for the TEP side.
In the public record: All homes in 85755 · Homes by ZIP code · Commercial property in 85755 · Permit data by neighborhood
Planning work at this home?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, sent once. No list.One email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list.
How this report was built
This is a reading of public records for parcel 21914006A — 19 permits on file from 1987 to 2022 (7 historical, 5 addition / alteration, 3 electrical / mechanical, 2 floodplain use) — assembled from the Pima County parcel file, the City of Tucson GIS layers, and Pima County’s Accela permit portal (searched by parcel and by address, because the county’s parcel links break on older records). Public records last checked 2026-08-18; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.