Electrical permit history — 8755 S Rita Rd

8755 S Rita Rd, Tucson — built 2002, with 44 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

8755 S Rita Rd

Built 2002 — 2000s commercial stock · HVAC 2021 (permit expired without a confirmed final)

Parcel
14122004L
Built
2002 (county record)
Jurisdiction
Tucson
Zoning
I-2
Assessor use
Manufacture Food Products
Parcel size
85.39 acres
Building area
499,616 sq ft (assessor record)
Sewer
Connection on file (2002) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 8755 S Rita Rd, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2022 firecons permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalPermitted — completion not confirmedA 2021 permit specifies this work (the permit description states “Installation of chiller and cooling tower”), but the available record does not show a final inspection. The permit expired without a confirmed final status. Official status: Expired. T21CM05762 — Installation of chiller and cooling tower
  • Fire alarm & life safetyCurrentA newer 2026 permit for the same system is recorded as “Issued” — The work was permitted, but final completion is not confirmed. The permit description states “Fire Alarm panel install for dedicated sprinkler monitoring”. Last permitted 2022 (4 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T22FC00049 — Install 3 new modules to monitor new sprinkler riser installed and permitted by Kazal Fire.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    Food service carries heavy, cycling kitchen loads and exhaust interlocks. Capacity and existing panel space are the first things to verify on any remodel.

Recorded sales (2)

Recorded transfers from the Pima County Assessor — 2 of 2
DatePriceType
2002-07-26$52,000,000Special Warranty Deed
2000-12-05$2,850,000Special Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2026-07-15 (TF-FCP-0726-00450) — Fire Alarm panel install for dedicated sprinkler monitoring.

Permit history (44)

Permit history for this parcel — 8 of 44 records
DateRecordWhatStatusValue
2026-07-15expires 2027-01-27TF-FCP-0726-00450City permit recordFire ConstructionFire Alarm panel install for dedicated sprinkler monitoringIssued
2026-06-11TC-COM-0626-00868City permit recordNew constructionTP-PRE-1125-00238, TD-DEV-0126-00008 Wastewater pretreatment expansion: 1. New concrete slab with canopy (sides are open air) covers wastewater process equipment. 2. New pre-engineered metal building to house electrical equipment, blowers, chemical dosing equipment. 3. Two new bolted-steel, open-top, above grade tanks wastewater equalization and biological treatment, two new closed-top FRP sludge storage tanks. 4. New cooling tower on 12’x12’ concrete slab. Split Commercial New Building application into (2) permits: 1. SEE SEPARATE PERMIT “Permit #1” two bolted steel wastewater treatment tanks, cooling tower, and sludge storage tanks, and associated underground piping TC-COM-0526-00737. 2. Permit #2 broken into “Phase 1” (Permit #2 Phase #1 SEE SEPARATE PERMIT TC-COM-0526-00763) foundation/slab design, associated piping to expedite review of concrete work. Permit #2 Phase 2 (******THIS PERMIT******) above-grade building/canopy structure, equipment anchorage, electrical, heating/cooling, plumbing disciplines, site civil, demolition, structural anchorage, electrical, HVAC, plumbing drawings & calculations.In review
2026-06-03expires 2027-01-25TC-UTL-0626-00079City permit recordUtilitiesThis Development Package submittal is a follow-up to the Pre-Application Conference review of the proposed wastewater pretreatment facility expansion at the Faribault Foods, Inc (Arizona Canning Company, LLC) site under Plan Number TP-PRE-1125-00238. The proposed construction will consist of: 1. A new concrete slab with a protective canopy of approximately 18’ interior eave height to cover the wastewater process equipment. The sides of the canopy will be open air. 2. A new pre-engineered metal building (PEMB) approximately 45’x38’ (1,710 square feet) to house electrical equipment, blowers, and chemical dosing equipment. 3. Two new bolted-steel, open-top, above grade tanks for wastewater equalization (47.5’ diameter and 32.5’ tall) and biological treatment (55.5’ diameter and 24.75’ tall), and two new closed-top FRP sludge storage tanks approximately 13’ diameter and 28’ tall. 4. A new cooling tower (18’ tall) installed on a 12’x12’ concrete slab.Inspections
2026-06-03TF-FCP-0626-00372City permit recordFire ConstructionVOID - Submitted new Permit#TF-FCP-0726-00450 - New fire alarm system for new wastewater pretreatment building and equipment canopy area associated with TD-DEV-0126-00008 and TC-COM-0526-00763.Void
2026-06-03TF-FCP-0626-00374City permit recordFire ConstructionVOID - Duplicate Permit#TF-FCP-0626-00372 - New fire automatic extinguishing system for new wastewater pretreatment building and equipment canopy area associated with TD-DEV-0126-00008 and TC-COM-0526-00763.Void
2026-05-22expires 2027-08-06TC-COM-0526-00763City permit recordNew constructionWastewater pretreatment expansion: 1. New concrete slab with canopy (sides are open air) covers wastewater process equipment. 2. New pre-engineered metal building to house electrical equipment, blowers, chemical dosing equipment. 3. Two new bolted-steel, open-top, above grade tanks wastewater equalization and biological treatment, two new closed-top FRP sludge storage tanks. 4. New cooling tower on 12’x12’ concrete slab. Split Commercial New Building application into (2) permits: 1. SEE SEPARATE PERMIT: “Permit #1” two bolted steel wastewater treatment tanks, cooling tower, sludge storage tanks, underground piping. Structural foundation/slab design. Special Inspections Certificate form be submitted prior to Start of Inspections as deferred submittal. 2. THIS PERMIT: Permit #2 broken into Phase 1” (******THIS PERMIT******) foundation/slab design to expedite review of concrete work. Permit #2 Phase 2 (SEE SEPARATE PERMIT) above-grade building/canopy structure, equipment anchorage, electrical, heating/cooling, plumbing disciplines.Inspections
2026-05-19expires 2027-08-06TC-COM-0526-00737City permit recordNew constructionWastewater pretreatment expansion: 1. New concrete slab with canopy (sides are open air) covers wastewater process equipment. 2. New pre-engineered metal building to house electrical equipment, blowers, chemical dosing equipment. 3. Two new bolted-steel, open-top, above grade tanks wastewater equalization and biological treatment, two new closed-top FRP sludge storage tanks. 4. New cooling tower on 12’x12’ concrete slab. Split Commercial New Building application into (2) permits: 1. (******THIS PERMIT******): “Permit #1” two bolted steel wastewater treatment tanks, cooling tower, sludge storage tanks, underground piping. Structural foundation/slab design. Special Inspections Certificate form be submitted prior to Start of Inspections as deferred submittal. 2. SEE SEPARATE PERMIT: Permit #2 broken into “Phase 1” foundation/slab design to expedite review of concrete work. Permit #2 Phase 2 above-grade building/canopy structure, equipment anchorage, electrical, heating/cooling, plumbing disciplines.Issued
2026-03-25expires 2029-07-06TD-DEV-0326-00077City permit recordDevelopment PackageThis Development Package submittal is a follow-up to the previous Development Package submitted under Plan Number TP-PRE-1125-00238 for the proposed wastewater pretreatment facility expansion at the Faribault Foods, Inc (Arizona Canning Company, LLC) site. This separate Development Package is associated with "At-risk Grading" in relation to the previous Development Package application and proposes to include only site grading work and proposed below grade wastewater piping associated with the project to improve the overall project timeline.Inspections
Show 36 older records
Permit history for this parcel — remaining 36 records
DateRecordWhatStatusValue
2026-01-09expires 2029-07-13TD-DEV-0126-00008City permit recordDevelopment PackageThis Development Package submittal is a follow-up to the Pre-Application Conference review of the proposed wastewater pretreatment facility expansion at the Faribault Foods, Inc (Arizona Canning Company, LLC) site under Plan Number TP-PRE-1125-00238. The proposed construction will consist of: 1. A new concrete slab with a protective canopy of approximately 18’ interior eave height to cover the wastewater process equipment. The sides of the canopy will be open air. 2. A new pre-engineered metal building (PEMB) approximately 45’x38’ (1,710 square feet) to house electrical equipment, blowers, and chemical dosing equipment. 3. Two new bolted-steel, open-top, above grade tanks for wastewater equalization (47.5’ diameter and 32.5’ tall) and biological treatment (55.5’ diameter and 24.75’ tall), and two new closed-top FRP sludge storage tanks approximately 13’ diameter and 28’ tall. 4. A new cooling tower (18’ tall) installed on a 12’x12’ concrete slab.Inspections
2025-06-12finaledTR-ROW-0625-00800City permit recordRight-of-Way (ROW)AZTEC will perform 3 utility potholes in the Rita Rd right of way at 8800 S Rita RdComplete
2023-05-09finaledTR-UTL-0523-01527City permit recordRight-of-Way (ROW) - UtilityCox to overlash 414' of existing CATV aerial strand, trench 25' & bore 135' to install new CATV conduit for system tie.Complete
2022-01-18finaledT22FC00049City permit recordFIRECONSInstall 3 new modules to monitor new sprinkler riser installed and permitted by Kazal Fire.Final
2021-10-12T21RW04647City permit recordROWS.2878460-2- ALONG WEST SIDE OF S. RITA RD. ACCESS MH 22824 TO SPLICE EXISTING CABLE.Withdrwn
2021-08-18finaledT21FC00643City permit recordFIRECONSModify existing wet pipe fire sprinkler system.Final
2021-08-06finaledT21RW03645City permit recordROWUNION PACIFIC RAILROAD HAS A 6 HOUR REPAIR REQUIRING A FULL CLOSURE THEY INTEND TO DO TO THE RAILROAD TRACKS LOCATED ON RITA WAY SOUTH OF E OLD VAIL ROAD.Final
2021-07-14T21CM05762City permit recordCommercial BuildingInstallation of chiller and cooling towerExpired
2021-06-11expired 2022-09-28T21CM04898City permit recordCommercial Buildingany exInstallation of Hydro-sterilization unit in the existing facility. Structural work includes thExpired
2021-02-19expired 2021-12-01T21CM01497City permit recordAddition / alterationBoiler AdditionExpired
2020-05-11finaledT20RW02638City permit recordROWPAVNG JULAIN WASH BIKE PATH, LANE CLOSURE FOR TRUCK ACCESS ****PERMIT FOR WORK WITHIN COT ROW ONLY**** ADDRESS CHANGED FROM "UPRR AT HOUGHTON & RITA ROAD" TO "8755 S RITA RD" ***CONTRACTOR MUST REACH OUT TO INSPECTOR FOR PRE-CON BEFOR ANY WORK CAN BE DONE***Final
2019-12-30finaledT19RW07763City permit recordROWEXCAVATE / INSPECT AND REPAIR KINDER MORGAN'S PETROLEUM PIPELINE (JET FUEL) PER FEDERAL D.O.T REQUIREMENTS.Final
2019-11-07finaledT19RW06867City permit recordROWSETUP MIOVISION SCOUT MOUNTED ON A POLE FOR 48-HOUR VIDEO COLLECTION IN THE AREA OF RITA ROAD AND OLD VAIL ROAD NOTE: WORK IS IN THE AREA OF THE RAILROAD TRACKS - ADDRESS ON PERMIT IS FOR PERMITTING PURPOSES ONLYFinal
2019-10-17finaledT19RW06193City permit recordROWSetting up a flagging operation near the railroad crossing for the railroad. The railroad signals will be shut off during working hours and flaggers will be placed at the crossing to act as a signal when trains and machines travel through the crossings. Traffic control will be set up per the TA-13 from the MUTCD. ADDRESS ON APPLICATION-8753 S RITA RDFinal
2018-08-06finaledT18FC00647City permit recordFIRECONSFIRE PANEL REPLACEMENTFinal
2018-06-20finaledT18RW02805City permit recordROWNEED (2) MH ACCESS FOR SPLICING ONLY MH # 24674 & 22824Final
2017-11-28expired 2018-08-15T17FC00961City permit recordFire ConstructionAutomatic Fire Extingshing Sys - INSTALL ESFR SYSTEM IN NEW COOLER FROM EXISTING WET PIPE FIRE SPRINKLER SYSTEM.; Commercial Fire Sprinkler Systems - Modification of heads: 36Expired
2016-08-12finaledT16RW01009City permit recordROW(2) 5x5 IN DIRT TO INSTALL ANODES ACROSS THE STREET FROM ADDRESS BY JULIAN WASH PASSFinal
2015-01-12T15TC00115City permit recordBARRICADJOB WILL REQ'D TO DIG A PIT TO LOCATE EXISTING CONDUIT, TRENCH +/-6' TO PLACE (1) 4" CONDUIT TO A NEW 3048 HANDHOLE, THEN TRRENCH ANOTHER +/-6' TO EXTEND (1) 4" CONDUIT TO AN EXISTING PEDESTAL. WORK WILL TAKE PLACE APPRX +/-30' OFFSET FROM RITA RD END OF CURVE SEE ATTCHED DETAIL FOR LOCATIONExpired
2009-08-28finaledT09BU01293City permit recordSPKLRInstall 39 fire sprinklersFinal
2009-07-28finaledT09BU01097City permit recordBUILDFIRE ALARMFinal
2009-05-05finaledT09BU00652City permit recordSPKLRInstall 580' of 12" & 493' of 8" underground & 968 fire sprinklersFinal
2009-04-16expired 2009-11-11T09CM00859City permit recordCOMBOFOUNDATION ONLYExpired
2009-02-26completed 2009-04-24T09SA00059VarianceZoning ComplianceVariance request to reduce parking associated with a warehouse expansionEffectuated
2009-01-23D09-0001City permit recordDevelopment PackageARIZONA CANNING FACILITY EXPANSIONApproved
2009-01-23T09BU00107City permit recordGRADSWPPGRADING Arizona Canning ExpansionWithdrwn
2009-01-23finaledT09CM00182City permit recordAddition / alterationADDITION: "FINISH PRODUCT" STORAGEFinal
2007-09-20finaledT07BU02001City permit recordSPKLR24 new sprinkler headsFinal
2007-03-22finaledT07BU00628City permit recordBUILDREPLACE FACP EQUIPMENT & RELATED DEVICESFinal
2007-03-09finaledT07BU00542City permit recordSPKLRremove and replace sprinkler pipingFinal
2007-03-09T07BU00543City permit recordSPKLRremove and replace sprinkler pipingWithdrwn
2007-01-31finaledT07CM00373City permit recordCOMBOREMOVE ROOF TO MODIFY STORK HYDROSTAT & REATTACH ROOFFinal
2007-01-17finaledT07CM00211City permit recordCOMBOFOUNDATION ONLY - FOR STORK HYDRO EQUIPMENT IN EXISTING BLDG.Final
2006-11-20finaledT06OT03017City permit recordSIGN12202Final
2006-10-09finaledT06CM05386City permit recordCOMBOFOUNDATION ONLY FOR FUTURE HYDRO STATFinal
2006-08-04T06OT02042City permit recordC-OF-OC OF O: FACTORY/STORAGEWithdrwn

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (4)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 4 of 4 records
DateRecordWhatStatus
2014-03-03T14DV01207Code enforcement caseCode enforcement caseNoverify
2009-04-23finaledT09FR01399Code enforcement caseFireComplete
2007-03-13finaledT07FR00478Code enforcement caseCode enforcement caseComplete
2007-01-19finaledT07FR00173Code enforcement caseCode enforcement caseComplete

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 14122004L — 44 permits on file from 2006 to 2026 (8 row, 5 spklr, 4 fire construction, 4 combo) and 4 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.