Electrical permit history — 6692 S Memorial Pl

6692 S Memorial Pl, Tucson — built 1998, with 21 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

6692 S Memorial Pl

Built 1998 — 1990s commercial stock · last permitted panel/service work 2020 (finaled) · HVAC 2009 (finaled)

Parcel
14108528A
Built
1998 (county record)
Jurisdiction
Tucson
Zoning
I-2
Assessor use
Manufacture Durable/Nondurable Goods
Parcel size
2.75 acres
Building area
47,820 sq ft (assessor record)
Sewer
Connection on file (2003) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)
Service on record
City records show the 2020 permit was finalized; the permit description states “New 120/240v 400amp 1Ph feeder”.

See the property

County aerial photograph centered on 6692 S Memorial Pl, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionCurrentLast permitted 2020 (6 years ago). City inspection record: COT - LCEL - Electrical Final approved 2022-01-19. Worth reading the permit itself: it names the service but does not read as an increase in capacity, so this may have been a like-for-like replacement rather than an upgrade. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. T20CM07324 — New 120/240v 400amp 1Ph feeder
  • Heating, cooling & mechanicalLikely dueLast permitted 2009 (17 years ago). City inspection record: BUILDING - FINAL approved 2009-05-01. Contractor of record: ACHILLES INC. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Equipment from before about 2010 generally runs R-22, which has not been produced since 2020 — repairs mean reclaimed refrigerant at a price that often exceeds replacing the unit. T09CM00789 — HVAC:EVAP UPGRADE
  • Fire alarm & life safetyGetting onLast permitted 2009 (17 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T09BU01055 — INSTALL 98 NEW FIRE SPRINKLER HEADS.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    Gear in this age range is usually still supported but is due for infrared scanning and torque verification if that has not been done recently. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    Industrial and warehouse space usually means three-phase motor loads. High-bay LED retrofits and added VFDs both change the load picture.

Most recent permit on record for this parcel: 2023-04-10 (TD-DEV-0423-00203) — Addition of free-standing canopy adjacent to existing warehouse facility..

Permit history (21)

Permit history for this parcel — 8 of 21 records
DateRecordWhatStatusValue
2023-04-10expires 2026-10-04TD-DEV-0423-00203City permit recordAddition / alterationAddition of free-standing canopy adjacent to existing warehouse facility.Issued
2022-12-19finaledTC-COM-1222-00321City permit recordCommercial BuildingConstruct a new shade structure on the side of an existing building. Shade structure will be independent and not attachedComplete
2020-12-28expired 2023-08-28T20CM09085City permit recordCommercial BuildingInstall Modular BuildingIssued
2020-11-25finaledDP20-0241City permit recordAddition / alterationSITE/GRADING - Customs and Border Patrol Modular, addition of a building and site work to existing bComplete
2020-10-25finaledT20CM07324City permit recordCommercial BuildingNew 120/240v 400amp 1Ph feederComplete
2017-10-27finaledT17RW04803City permit recordROWACCESS EXISTING HANDHOLEFinal
2016-02-01finaledT16EL00023City permit recordELECTElectrical Re-connect (VH)Final
2015-12-04finaledT15CM08499City permit recordCOMBOSECURITY IMPROVEMENTS.COMML of c
Show 13 older records
Permit history for this parcel — remaining 13 records
DateRecordWhatStatusValue
2009-09-17finaledT09CM02526City permit recordCOMBOPARKING LOTFinal
2009-07-17finaledT09BU01055City permit recordSPKLRINSTALL 98 NEW FIRE SPRINKLER HEADS.Final
2009-05-15finaledT09CM01244City permit recordCOMBOTEMP CONSTRUCTION TRAILERFinal
2009-05-01finaledT09CM01081City permit recordCOMBOTI:INTERIOR DEMO & PADSFinal
2009-04-27finaledT09CM01027City permit recordAddition / alterationTI:OFFICE:ADDITION:MEZZANINEC of o
2009-04-07finaledT09CM00789City permit recordCOMBOHVAC:EVAP UPGRADEFinal
2008-09-11finaledT08CM03064City permit recordCOMBOTEMP CONSTRUCTION TRAILER R1: ELECTRICALFinal
1998-02-27expired 1998-04-28T98EX00245City permit recordEXCAVEXCAV:APRON 10LF:SIDEWALK 80LFClosed
1998-02-24finaledT98BU00470City permit recordSPKLRFIRE SPKR:NEW 340Final
1998-02-03finaledT98BU00308City permit recordSPKLRFIRE SPKR:UNDERGROUND PIPEFinal
1998-01-30finaledT98CM00427City permit recordCOMBOWAREHOUSEFinal
1998-01-16finaledT98BU00107City permit recordGRADINGGRADING: 1900 CY CUT & 1900 CY FILLFinal
1998-01-06finaledD98-0001City permit recordDevelopment PackageEDWARDS PAPER COComplete

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (1)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 1 of 1 records
DateRecordWhatStatus
2008-10-06finaledT08FR03543Code enforcement caseCode enforcement caseComplete

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 14108528A — 21 permits on file from 1998 to 2023 (7 combo, 3 addition / alteration, 3 commercial building, 3 spklr) and 1 code enforcement case — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.