Electrical permit history — 6251 S Wilmot Rd

6251 S Wilmot Rd, Tucson — built 2001, with 32 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

6251 S Wilmot Rd

Built 2001 — 2000s commercial stock · last permitted panel/service work 2017 (finaled)

Parcel
14103024B
Built
2001 (county record)
Jurisdiction
Tucson
Zoning
I-2
Assessor use
Privately Owned Vocational School>Adults
Parcel size
16.72 acres
Building area
19,947 sq ft (assessor record)
Sewer
Connection on file (2002) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)
Service on record
City records show the 2017 permit was finalized; the permit description states “REPLACE 690 LF OF NATURAL GAS LINES. 89 LF VIA BORING IN PAVEMENT; 605 LF VIA TRENCHING IN DIRT PER APPROVED DESIGN 10/04/2017-ADDITIONAL WORK INCLUDES 212 LF OF NEW 4" STEEL SERVICE FOR NEW DAVIS MONTHAN METER. WILL BORE UNDER WILMOT RD PER PLAN”.

See the property

County aerial photograph centered on 6251 S Wilmot Rd, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionCurrentLast permitted 2017 (9 years ago). City inspection record: last recorded inspection 2017-12-26; no approved final is shown. Contractor of record: NPL CONSTRUCTION CO. Worth reading the permit itself: it names the service but does not read as an increase in capacity, so this may have been a like-for-like replacement rather than an upgrade. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. T17RW03012 — REPLACE 690 LF OF NATURAL GAS LINES. 89 LF VIA BORING IN PAVEMENT; 605 LF VIA TRENCHING IN DIRT PER APPROVED DESIGN 10/04/2017-ADDITIONAL WORK INCLUDES 212 LF OF NEW 4" STEEL SERVICE FOR NEW DAVIS MONTHAN METER. WILL BORE UNDER WILMOT RD PER PLAN
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2019 addition / alteration permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyLikely dueA newer 2021 permit for the same system is recorded as “Expired” — The permit expired without a confirmed final status. The permit description states “Fire Alarm & Detection Systems - Installing a Riser Monitoring System with built in cell communicator.; Fire Alarm Systems - New Sq Ft: 17555”. Last permitted 2000 (26 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T00BU03419 — FIRE:SPKR:194 NEW
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    Gear in this age range is usually still supported but is due for infrared scanning and torque verification if that has not been done recently. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

Recorded sales (1)

Recorded transfers from the Pima County Assessor — 1 of 1
DatePriceType
1999-05-28$266,666Special Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2026-05-08 (TR-ROW-0526-00556) — Barricade only for COT ROW. Work is in EPNG easement. Cathartic Protection upgrade. Contractor will drill one-500’ deep by 10” diameter hole and will install anodes and backfill. Contractor will trench and install #2 copper positive header cable from the anode ground bed to the rectifier approximately 75’ away. Contractor will drill one-500’ deep by 10” diameter hole and will install anodes and backfill. Contractor will trench and install #2 copper positive header cable from the anode ground bed to the rectifier approximately 75’ away. Contractor will install a concrete slab and guard rail around the ground bed and anode J-box. 06/25/2026 - Request for 90 Day Renewal as of 07/19/2026.

Permit history (32)

Permit history for this parcel — 8 of 32 records
DateRecordWhatStatusValue
2026-05-08expires 2026-10-17TR-ROW-0526-00556City permit recordRight-of-Way (ROW)Barricade only for COT ROW. Work is in EPNG easement. Cathartic Protection upgrade. Contractor will drill one-500’ deep by 10” diameter hole and will install anodes and backfill. Contractor will trench and install #2 copper positive header cable from the anode ground bed to the rectifier approximately 75’ away. Contractor will drill one-500’ deep by 10” diameter hole and will install anodes and backfill. Contractor will trench and install #2 copper positive header cable from the anode ground bed to the rectifier approximately 75’ away. Contractor will install a concrete slab and guard rail around the ground bed and anode J-box. 06/25/2026 - Request for 90 Day Renewal as of 07/19/2026Issued
2024-03-14finaledTR-ROW-0324-00296City permit recordRight-of-Way (ROW)TEP work. We will be in the right of way along Wilmot for the primary power conduit.Complete
2021-12-16finaledT21FO00884City permit recordFIREOPER2 TENTS POTLUCK 100 GUEST 12/27/21 TO 12/29/21Final
2021-10-13finaledT21RW04657City permit recordROWN.805598-3- ALONG WEST SIDE OF S. WILMOT RD, SOUTH OF E VALENCIA RD ACCESS HH 10540 TO SPLICE EXISTING CABLE.Final
2021-02-05expired 2022-06-26T21FC00089City permit recordFire ConstructionFire Alarm & Detection Systems - Installing a Riser Monitoring System with built in cell communicator.; Fire Alarm Systems - New Sq Ft: 17555Expired
2020-01-13finaledT20RW00168City permit recordFence / wallBUILD A 6' TALL BLOCK WALL AROUND EXISTING SW GAS REGULATOR.Final
2020-01-09finaledT20RW00121City permit recordROWN.653824 JOB WILL REQUIRE ACCESS TO MH#10540 TO SPLICE FIBERFinal
2019-10-24finaledT19RW06482City permit recordROWN.528518 JOB WILL BORE 100' OF NEW CONDUIT. R/R 34SQFT ASPHALT. 1197' OF NEW AERIAL CABLE PLACEMENT. REMOVE AND REPLACE A 3048 HH WITH A NEW BIGSHOT PED. (1) NEW 3048 HHFinal
Show 24 older records
Permit history for this parcel — remaining 24 records
DateRecordWhatStatusValue
2019-06-25finaledT19RW03616City permit recordFence / wallCONSTRUCTION OF A BLOCK WALL AROUND SW GAS REGULATORFinal
2019-05-15finaledT19RW02752City permit recordAddition / alteration(6) 5 X 5 BELLHOLES IN DIRT FRONT AND APPROX 60-80 FT TRENCING ALL IN DIRT- TO INSTALL/REPAIR SWG REG STATION 05/30/2019-PLAN CHANGE IN ADDITION TO THE PREVIOUS- (5) 5 X 5 BELLHOLES IN ROW AND APPROX 180-200 FT TRENCHING ALL IN DIRT SHOULDER TO INSTALL/REPAIR SWG REG STATIOIN OUTLET MAINFinal
2019-05-01finaledT19RW02419City permit recordROW87' of trenching and 1,528' of aerial placement. 37sqft of asphalt to be removed & replaced. 06/28/2019- PLAN CHANGE N.528518 100 FT OF BORING 34 SQ FT OF TRENCHING, 1197 FT OF AERIAL CABLE PLACEMENT, REMOVAL OF 1248 PED TO PLACE BIG SHOT AND PLACEMENT OF HHFinal
2017-07-14finaledT17RW03012City permit recordAddition / alterationREPLACE 690 LF OF NATURAL GAS LINES. 89 LF VIA BORING IN PAVEMENT; 605 LF VIA TRENCHING IN DIRT PER APPROVED DESIGN 10/04/2017-ADDITIONAL WORK INCLUDES 212 LF OF NEW 4" STEEL SERVICE FOR NEW DAVIS MONTHAN METER. WILL BORE UNDER WILMOT RD PER PLANFinal
2011-08-10expired 2012-07-04T11OT01579City permit recordSIGN19840Expired
2011-08-02expired 2011-10-01T11EX00406City permit recordEXCAVEXCAVATING +/- TO PLACE TIME WARNER FACILITIES WITHING R/WClosed
2010-02-25finaledT10OT00452City permit recordFLOODPLNFLOODPLAIN USE PERMIT: Open sided CarportFinal
2010-02-16finaledT10BU00286City permit recordBUILDTD#16-91-04 T07-M0096 CARPORTS - PATIO COVER - LATTICE COVERS - SOLID LATTICE COVERS - LRP PANEL COVERFinal
2009-03-04finaledT09BU00319City permit recordGRADSWPPGRADINGFinal
2009-03-04T09OT00456City permit recordFLOODPLNFUP: GRADING PLANIssued
2008-03-28D08-0023City permit recordDevelopment PackageD & K TRUCKING (PHASE 2)Approved
2005-08-22expired 2006-08-24T05OT02087City permit recordPEDDLERZERIMAR HOT DOG / JESUS RAMIREZ REGULATED PEDDLERExpired
2001-08-14expired 2001-10-13T01EX00932City permit recordEXCAVEXCAV:REPAIR DRIVEWAYClosed
2001-05-30finaledT01CM02586City permit recordCOMBONEW:MODULAR TRAILERC of o
2001-05-23finaledT01PL01061City permit recordPLUMBFINALS ONLY PERMITFinal
2001-05-11finaledT01EL01189City permit recordELECTELECTRIC: FOR FUEL TANKFinal
2001-05-04expired 2001-07-03T01EX00515City permit recordEXCAVEXCAV:600 LF TO ISNTALL 2 DRIVES AND DECEL LANEClosed
2001-02-09finaledT01BU00302City permit recordTANKSFUEL TANK:12000 GALLONFinal
2001-01-08expired 2001-03-09T01EX00020City permit recordEXCAVEXCAV:80 LF OF TRENCH FOR ELECTRICClosed
2000-11-20finaledT00BU03419City permit recordSPKLRFIRE:SPKR:194 NEWFinal
2000-09-11finaledT00BU02739City permit recordSPKLRFIRE:8LF UG PIPE/5'STUB OUT ONLYFinal
2000-08-24expired 2000-10-23T00EX01114City permit recordEXCAVEXCAV:ROW IMPROVEMENTS 600LFClosed
2000-03-22expired 2000-11-12T00PL00702City permit recordPLUMBPRIVATE SEWERWithdrwn
1999-11-24finaledT99CM05570City permit recordCOMBOOFFICE:STORAGEC of o

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (5)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 5 of 5 records
DateRecordWhatStatus
2018-03-06T18DV01129Code enforcement caseRefuseComplian
2017-03-29T17DV01291Code enforcement caseRefuseNoverify
2009-09-01finaledT09FR02811Code enforcement caseFireComplete
2007-10-08finaledT07FR02001Code enforcement caseCode enforcement caseComplete
2007-10-04T07DV10443Code enforcement caseCode enforcement caseComplian

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 14103024B — 32 permits on file from 1999 to 2026 (5 excav, 4 row, 2 right-of-way (row), 2 fence / wall) and 5 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.