Electrical permit history — 6818 S Country Club Rd

6818 S Country Club Rd, Tucson — built 2022, with 24 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

6818 S Country Club Rd

Built 2022 — 2020s commercial stock · HVAC 2023 (finaled)

Parcel
14042065C
Built
2022 (assessor record)
Jurisdiction
Tucson
Zoning
I-1
Assessor use
Warehousing
Parcel size
25.85 acres
Building area
230,879 sq ft (assessor record)
Sewer
No connection on file (sewer or septic status not confirmed by the record — verify on site)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 6818 S Country Club Rd, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2024 fire construction permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalCurrentLast permitted 2023 (3 years ago). City inspection record: COT - FCON - Fire - Final approved 2024-04-12. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. TC-COM-1123-02588 — Tenant improvement, Manufacturing use, adding 2 toilet rooms, and expanding the existing office area. Adding one new mechanical unit, and related lighting and power
  • Fire alarm & life safetyCurrentLast permitted 2024 (2 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. TF-FCP-0124-00044 — Modify existing fire sprinkler system to accommodate new interior buildout.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    A capacity and condition review is the usual starting point before any tenant improvement or added load. The permit record does not confirm this; an on-site inspection is required.

Most recent permit on record for this parcel: 2025-03-10 (TR-UTL-0325-00391) — C.3059435 - ACCESS MH 14714 & MH 14171 FOR SPLICING.

Permit history (24)

Permit history for this parcel — 8 of 24 records
DateRecordWhatStatusValue
2025-03-10expired 2025-04-27TR-UTL-0325-00391City permit recordRight-of-Way (ROW) - UtilityC.3059435 - ACCESS MH 14714 & MH 14171 FOR SPLICINGInspections
2024-04-16expired 2024-12-29TC-COM-0424-00682City permit recordCommercial BuildingInstallation of new SWSIssued
2024-03-29finaledTS-PRM-0324-00142City permit recordFence / wallInstall one non-lighted wall sign.Complete
2024-03-13TC-CFO-0324-00063Certificate of occupancyTemporary Certificate-of-Occupancy (TCO)L of C issued Engineering, Manufacturing, Conveyor Electrical Design, and complete Turnkey Installation of a Package Handling Automated System in a leased warehouse. Work shall include, but not limited to, conveyor and conveyor electrical installation design to include a 30%, 80%, and 100% Owners review.163800 sq ftDenied$11,265,069
2024-03-04TC-CFO-0324-00058Certificate of occupancyTemporary Certificate-of-Occupancy (TCO)This project needs the okay for a Temporary Certificate of Occupancy from a Building Inspector and Fire Inspector and the level of Temporary Certificate of Occupancy (TCO) for the building. Please re-request on the inspector has given the okay for TCO Full build out of suites 100 thru 160 for United Parcel Service and their sorting/distribution operations.162980 sq ftDenied$2,800,000
2024-01-18finaledTF-FCP-0124-00044City permit recordFire ConstructionModify existing fire sprinkler system to accommodate new interior buildout.Complete
2023-11-21TF-FCP-1123-01337City permit recordFire ConstructionVOID-Submit under Permit#TF-FCP-0623-00821 - installing sprinkler heads below conveyors in all areas where more than 48 inches wideVoid
2023-11-03finaledTC-COM-1123-02588City permit recordCommercial BuildingTenant improvement, Manufacturing use, adding 2 toilet rooms, and expanding the existing office area. Adding one new mechanical unit, and related lighting and powerComplete
Show 16 older records
Permit history for this parcel — remaining 16 records
DateRecordWhatStatusValue
2023-09-04finaledTR-UTL-0923-02414City permit recordRight-of-Way (ROW) - UtilityPRJ256520-1 COX TO OVERLASH 144F ON 2 POLES, & PLACE NEW ATTACHMENT/PLANT 144CT ON 8 POLES FOR 1,764'Complete
2023-07-12finaledTF-FCP-0723-00854City permit recordFire ConstructionFuel tank submittalComplete
2023-07-12TF-FCP-0723-00855City permit recordFire ConstructionVOID-SUBMIT A FIRE GENERAL OPERATIONAL PERMIT AND ADD OWNER TO CONTACTS-GENERAL OPERATIONAL PERMITVoid
2023-07-05finaledTF-FCP-0723-00827City permit recordFire ConstructionNew Fire Alarm SystemComplete
2023-06-29finaledTF-FCP-0623-00821City permit recordFire Constructionups ti adding 55 new sprinkler heads below ceiling for new offices and restroomsComplete
2023-06-23finaledTR-UTL-0623-01865City permit recordRight-of-Way (ROW) - UtilityP.129913 : ACCESS OF EX MH 15520 FOR SPLICING, REPLACE (1) PED AND BORE 179'Complete
2023-06-05applied 2023-04-27 · expired 2023-07-05TC-CFO-0423-00058Certificate of occupancyTemporary Certificate-of-Occupancy (TCO)This project will need the okay for TCO from an inspector in fire and the level of TCO. Please re-request once you get the okay for TCO from the fire inspector- TI: TUCSON AIRPORT CENTER2746 sq ftIssued$170,000
2023-04-27TC-CFO-0423-00059Certificate of occupancyTemporary Certificate-of-Occupancy (TCO)This project will need the okay for TCO from an inspector in fire and building and the level of TCO. Please re-request once you get the okay for TCO TI: TUCSON AIRPORT CENTER2746 sq ftNeeds Resubmittal$170,000
2023-04-19applied 2023-02-28 · finaledTS-PRM-0223-00212SignPermanent Sign3 WALL SIGNS, 1 MONUMENT SIGN, 1 DIRECTIONAL SIGNInspections Complete
2023-04-11finaledTC-COM-0423-01020City permit recordCommercial BuildingEngineering, Manufacturing, Conveyor Electrical Design, and complete Turnkey Installation of a Package Handling Automated System in a leased warehouse. Work shall include, but not limited to, conveyor and conveyor electrical installation design to include a 30%, 80%, and 100% Owners review.Complete
2023-02-20applied 2022-09-12 · finaled 2023-07-01T22CM06960Certificate of occupancyAddition / alterationTI: TUCSON AIRPORT CENTER2746 sq ftComplete$170,000
2022-11-28finaledTC-COM-1122-00184City permit recordCommercial BuildingFull build out of suites 100 thru 160 for United Parcel Service and their sorting/distribution operations.Complete
2022-09-12finaledT22CM06963City permit recordCommercial BuildingTI: TUCSON AIRPORT CENTERComplete
2021-12-23expires 2027-12-31T21CM09845Commercial buildingNew constructionProposed construction of a 141,960 sf shell building and associated site work141960 sq ftFees Due$7,732,845
2020-12-16DS20-18Design modificationZoning Verification LetterTucson Airport Center (TAC 2), TSMR - TSMR - Tucson Airport Center. Standard number 8-01.5.0, garbage enclosures.Approved
1999-06-21applied 1999-02-18 · expired 1999-12-18T99OT00048Development packageDevelopment PackageSITE:PARKING LOTIssued

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 14042065C — 24 permits on file from 1999 to 2025 (6 fire construction, 5 commercial building, 4 temporary certificate-of-occupancy (tco), 3 right-of-way (row) - utility) — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.