Electrical permit history — 6950 S Country Club Rd

6950 S Country Club Rd, Tucson — built 1978, with 44 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

6950 S Country Club Rd

Built 1978 — 1970s commercial stock · 44 permits on record; no permitted panel/service or HVAC work among them

Parcel
14042023D
Built
1978 (county record)
Jurisdiction
Tucson
Zoning
I-1
Assessor use
Spec Purpose Manuf Industrial Complex
Parcel size
9.85 acres
Building area
108,245 sq ft (assessor record)
Sewer
Connection on file (2007, 2009) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 6950 S Country Club Rd, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 fire construction permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 fire construction permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyCurrentLast permitted 2025 (1 year ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. TF-FCP-1025-00924 — EXPEDITE - NFP to modify the existing fire sprinkler system.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    Industrial and warehouse space usually means three-phase motor loads. High-bay LED retrofits and added VFDs both change the load picture.

  • Worth confirming

    Solar was permitted here in 2009. That means there is an existing interconnection, and the main breaker and busbar rating already carry a PV backfeed — so anything else you add (an EV charger, a heat pump) has to be checked against what is left under the 120% rule, not against the service size alone.

Recorded sales (1)

Recorded transfers from the Pima County Assessor — 1 of 1
DatePriceType
2005-04-29$2,000,000Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2026-06-03 (TR-UTL-0626-00940) — wo#3046334 6950 s country club rd 15 14 17 se replace valve eastside of bldg in dirt and asphalt 6LF/sc.

Permit history (44)

Permit history for this parcel — 8 of 44 records
DateRecordWhatStatusValue
2026-06-03TR-UTL-0626-00940City permit recordRight-of-Way (ROW) - Utilitywo#3046334 6950 s country club rd 15 14 17 se replace valve eastside of bldg in dirt and asphalt 6LF/scNeeds resubmittal
2026-02-27expires 2027-04-17TC-REG-0226-00008City permit recordRegistered FacilityIssued
2025-10-22finaledTF-FCP-1025-00924City permit recordFire ConstructionEXPEDITE - NFP to modify the existing fire sprinkler system.Complete
2025-10-07finaledTR-UTL-1025-01750City permit recordRight-of-Way (ROW) - Utility4' x 10' BELL HOLE IN DIRT TO INSTALL NEW GAS SERVICE.Complete
2025-10-01finaledTF-FCP-1025-00872City permit recordFire ConstructionDemo 4 sprinkler where canopy is being removedComplete
2025-08-05expired 2026-03-11TS-PRM-0825-00335City permit recordSign - PermanentLED Illuminated cabinet on existing monument structureIssued
2025-05-12finaledTC-COM-0525-00973City permit recordAddition / alterationThis project includes the installation of RTO equipment, the addition of a new gas main, and the removal of existing equipment and canopy to make room for new equipment at RBC Bearings located at 6950 S. Country Club Road, Tucson, Arizona 85756.Complete
2025-05-09finaledTC-COM-0525-00955City permit recordCommercial BuildingManufacturing floor tenant improvement (NOTE: C of O cannot be issued until the RTO2 mechanical equipment is installed and passed inspection via a separate permit.)Complete
Show 36 older records
Permit history for this parcel — remaining 36 records
DateRecordWhatStatusValue
2025-05-05finaledTC-COM-0525-00909City permit recordCommercial BuildingOffice tenant improvementComplete
2025-03-07finaledTF-FCP-0325-00197City permit recordFire Constructioninstall a Starlink cellular transmitter to monitor the existing building FACPComplete
2021-04-22finaledT21CM03403City permit recordCommercial BuildingPSE Relocation Electrical OnlyComplete
2017-04-03finaledT17CM02534City permit recordCOMBOPULLING NEW FEEDERS TO GEAR FOR ELECTRICALFinal
2013-01-23expired 2023-04-05T13BU00082City permit recordSPKLRAdd 20 fire sprinklersClosed
2011-05-02expired 2011-07-01T11EX00211City permit recordEXCAV320 LF OF TRENCHINGClosed
2009-10-01finaledT09CM02647City permit recordSolar PVADDITION:PARKING CANOPIES W/SOLAR PANELSFinal
2009-02-02T09BU00152City permit recordSolar PVGRADING FOR TEST SITE FOR SOLAR PANELSWithdrwn
2009-02-02T09CM00244City permit recordSolar PVFOUNDATION, RACKS AND EQUIPMENT, ELECTRICAL FOR SOLAR PANELSWithdrwn
2008-10-13finaledT08OT02432City permit recordSIGN15733Final
2008-09-19finaledT08BU01701City permit recordBUILDFIRE ALARMFinal
2008-09-17finaledT08CM03125City permit recordFence / wallADDT: SITE WALL & CANOPYFinal
2008-08-29finaledT08BU01591City permit recordSPKLRInstall 155 fire sprinklersFinal
2008-08-27expired 2008-10-26T08EX00694City permit recordEXCAVTRENCH AND REPAIR 10 LF FROM EXISTING QWEST MANHOLClosed
2008-08-21T08OT01980City permit recordSIGN15324Closed
2008-08-08finaledT08CM02734City permit recordCOMBOTI: RACKING SYSTEMFinal
2008-08-07expired 2009-03-01T08BU01442City permit recordSPKLRAdd 40, replace 940 fire sprinklersClosed
2008-07-25finaledT08CM02577City permit recordCOMBOTI: MANUFACTURINGC of o
2008-07-17finaledT08OT01716City permit recordSIGN15324Final
2008-06-17finaledT08CM02154City permit recordCOMBOTI: OFFICE/WAREHOUSEFinal
2008-03-21finaledT08CM00940City permit recordCOMBOTI: WAREHOUSE AND MANUFACTORINGC of o
2008-03-11finaledT08EL00397City permit recordELECTRELOCATE SWITCH GEAR FOR TEMP POWERFinal
2008-01-16finaledT08CM00155City permit recordCOMBOINSTALL:THICKENED SLAB AND NEW DOORFinal
2007-06-22finaledT07BU01386City permit recordSPKLRAdd 1176 fire sprinklersFinal
2007-05-25T07BU01191City permit recordDEMODEMO:WAREHOUSEWithdrwn
2007-05-25expired 2008-11-21T07EL01009City permit recordELECTELEC REPAIR TO REMOVE DAMAGED ELECClosed
1999-05-07T99OT00138City permit recordSITESITE:PARKING LOTWithdrwn
1998-07-06finaledT98BU01674City permit recordBUILDHANDICAP RAMPFinal
1998-07-01finaledT98EL01189City permit recordELECTELECTRIC: DEFERRED SUBMITTALFinal
1998-05-21P98AN01213City permit recordADDRNEWIssued
1998-05-21T98CM02216City permit recordCOMBOROUGH PLUMB:DEFERRED SUBWithdrwn
1998-05-18T98CM02142City permit recordCOMBOREMODEL:INTERIOR DEMOWithdrwn
1997-08-09finaledT97BU01563City permit recordSPKLRSPRINKLER:ADD 7Final
1997-06-25finaledT97BU01177City permit recordSPKLRFIRE SPKR:ADD 402Final
1997-04-10finaledT97CM00797City permit recordCOMBOTI:OFFICE/MANUFACTURINGC of o
1997-04-07T97CM00717City permit recordCOMBOTENANT IMPROVEMENT:OFFICEWithdrwn

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (9)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 8 of 9 records
DateRecordWhatStatus
2009-01-22finaledT09FR00309Code enforcement caseCode enforcement caseComplete
2008-11-12finaledT08FR04298Code enforcement caseFireComplete
2008-07-25T08FR02139Code enforcement caseCode enforcement caseInvalid
2008-07-25finaledT08FR02140Code enforcement caseCode enforcement caseComplete
2008-07-25finaledT08FR02145Code enforcement caseFireComplete
2007-05-24T07DV04759Code enforcement caseWork without permitComplian
2007-05-11finaledT07FR00937Code enforcement caseFireComplete
2001-06-03T01VL01465Code enforcement caseCode enforcement caseClosed
Show 1 older record
Code enforcement history for this parcel — remaining 1 records
DateRecordWhatStatus
1999-03-19T99VL00772Code enforcement caseCode enforcement caseComplian

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 14042023D — 44 permits on file from 1997 to 2026 (10 combo, 6 spklr, 3 fire construction, 3 commercial building) and 9 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.