Electrical permit history — 3870 E Valencia Rd

3870 E Valencia Rd, Tucson — built 2023, with 56 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

3870 E Valencia Rd

Built 2023 — 2020s commercial stock · last permitted panel/service work 2024 (permitted, completion not confirmed) · HVAC 2025 (finaled)

Parcel
14041124E
Built
2023 (assessor record)
Jurisdiction
Tucson
Zoning
I-1
Assessor use
Warehouse W/ Office/ Retail
Parcel size
15.37 acres
Building area
263,999 sq ft (assessor record)
Sewer
Connection on file (2024, 2025) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)
Service on record
A 2024 permit was issued; completion is not confirmed in the available record; the permit description states “New TEP transformer and a 4000amp SES install and East electrical service relocate”.

See the property

County aerial photograph centered on 3870 E Valencia Rd, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionPermitted — completion not confirmedA 2024 permit specifies this work (the permit description states “New TEP transformer and a 4000amp SES install and East electrical service relocate”), but the available record does not show a final inspection. The work was permitted, but final completion is not confirmed. Official status: Issued. City inspection record: last recorded inspection 2024-09-27; no approved final is shown. TC-COM-0124-00106 — New TEP transformer and a 4000amp SES install and East electrical service relocate
  • Heating, cooling & mechanicalCurrentLast permitted 2025 (1 year ago). City inspection record: COT - FCON - Sprinkler - Final approved 2025-11-18. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. TF-FCP-0525-00391 — Install coverage to walk in chiller and walk in freezer. Relocate riser bank to the east
  • Fire alarm & life safetyCurrentLast permitted 2025 (1 year ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. TF-FCP-0525-00404 — Provide new Fire Alarm System addition in TI construction space.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Worth confirming

    Industrial and warehouse space usually means three-phase motor loads. High-bay LED retrofits and added VFDs both change the load picture.

  • Worth confirming

    A pool or spa was permitted in 2025. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.

  • Worth confirming

    Solar was permitted here in 2023. That means there is an existing interconnection, and the main breaker and busbar rating already carry a PV backfeed — so anything else you add (an EV charger, a heat pump) has to be checked against what is left under the 120% rule, not against the service size alone.

Most recent permit on record for this parcel: 2025-12-05 (TC-CFO-1225-00177) — Amazon Grocery Tenant Improvement.

Permit history (56)

Permit history for this parcel — 8 of 56 records
DateRecordWhatStatusValue
2025-12-05finaledTC-CFO-1225-00177City permit recordCertificate of OccupancyAmazon Grocery Tenant ImprovementComplete
2025-06-06finaledTD-DEV-0625-00153City permit recordDevelopment PackageSite Improvements associated with Grocery Tenant Improvement Project associated with permit number TC-COM-0125-00169Complete
2025-05-20finaledTF-FCP-0525-00404City permit recordPool / spaProvide new Fire Alarm System addition in TI construction space.Complete
2025-05-14finaledTF-FCP-0525-00391City permit recordFire ConstructionInstall coverage to walk in chiller and walk in freezer. Relocate riser bank to the eastComplete
2025-01-27finaledTC-COM-0125-00169City permit recordCommercial BuildingAmazon Grocery Tenant ImprovementComplete
2024-12-12finaledTC-CFO-1224-00253City permit recordCertificate of OccupancyTCO WAS ISSUED THIS MORNING EXPIRES 01/15/2025. WHEN REQUESTING TCO EXTENSION PLEASE REQUEST IN JANUARY PRIOR TO 01/15/2025 UNDER TC-CFO-1024-00212. DO NOT MAKE A NEW REQUEST. a tenant finish for an existing one story single sided dock warehouse / distribution buildingComplete
2024-12-09finaledTC-CFO-1224-00244City permit recordCertificate of OccupancyPLESE PAY TCO EXTENSION FEE UNDER TC-CFO-1024-00212.WHEN REQUESTING TCO EXTENSION DO NOT CREATE A NEW REQUEST. PLEASE REQUEST UNDER THE FIRST REQUEST TC-CFO-1024-00212 a tenant finish for an existing one story single sided dock warehouse / distribution buildingComplete
2024-11-07finaledTC-CFO-1124-00224City permit recordCertificate of OccupancyPLEASE PAY TCO EXTENSION UNDER TC-CFO-1024-00212. WHEN REQUESTING PLEASE DO NOT START A NEW REQUEST. IF ANOTHER EXTENSION IS NEEDED REQUEST EXTENSION UNDER TC-CFO-1024-00212 a tenant finish for an existing one story single sided dock warehouse / distribution buildingComplete

48 older records are not shown here. — each links to its official file.

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (5)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 5 of 5 records
DateRecordWhatStatus
2025-03-10CE-VIO0325-01026Code enforcement caseVegetationClosed - unfounded
2024-12-11CE-VIO1224-04933Code enforcement caseVegetationClosed - unfounded
2023-02-09CE-VIO0223-01816Code enforcement caseCode enforcement caseClosed - resolved
2013-05-08T13DV03164Code enforcement caseVegetationComplian
2008-01-28T08DV00760Housing code violationWEEDSrecorded before 2023COMPLIAN

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 14041124E — 56 permits on file from 2016 to 2025 (11 fire construction, 9 row, 7 certificate of occupancy, 7 commercial building) and 5 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.