Electrical permit history — 6690 S Alvernon Wy
6690 S Alvernon Wy, Tucson — built 2023, with 35 permits on record. Review electrical, HVAC and remodel history with links to official records.
Commercial property
6690 S Alvernon Wy
Built 2023 — 2020s commercial stock · last permitted panel/service work 2023 (finaled); a newer 2024 permit is issued
Permanent link: Electrical permit history for 6690 S Alvernon Wy (aztucsonelectricalsolutions.com/property/14041124c/6690-s-alvernon-wy-tucson-az-85756) · Public records last checked 2026-08-16
- Parcel
- 14041124C
- Built
- 2023 (assessor record)
- Jurisdiction
- Tucson
- Zoning
- I-1
- Assessor use
- Warehouse W/ Office/ Retail
- Parcel size
- 14.95 acres
- Building area
- 244,889 sq ft (assessor record)
- Sewer
- Connection on file (2024) (county sewer connection records)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
- Service on record
- City records show the 2023 permit was finalized; the permit description states “WO T59217. TEP to work in/near ROW along East Palo Verde and South Valencia. TEP to complete riser installation and pull in primary cable for new service connection of Tucson Commerce Center.”.
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionCurrentA newer 2024 permit for the same system is recorded as “Inspections” — The work was permitted, but final completion is not confirmed. The permit description states “New TEP transformer and a 4000amp SES install”. Last permitted 2023 (3 years ago). City inspection record: TRSP - ROW - Final/Close-Out approved 2024-06-19. Applicant on the permit: Desert Barricades LLC. Worth reading the permit itself: it names the service but does not read as an increase in capacity, so this may have been a like-for-like replacement rather than an upgrade. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. TR-UTL-0723-02039 — WO T59217. TEP to work in/near ROW along East Palo Verde and South Valencia. TEP to complete riser installation and pull in primary cable for new service connection of Tucson Commerce Center.
- Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2024 pool / spa permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
- Fire alarm & life safetyCurrentLast permitted 2024 (2 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. TF-FCP-0924-00757 — Tie-in of new devices to existing fire alarm system
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Worth confirming
Industrial and warehouse space usually means three-phase motor loads. High-bay LED retrofits and added VFDs both change the load picture.
- Worth confirming
A pool or spa was permitted in 2024. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.
- Worth confirming
Solar was permitted here in 2023. That means there is an existing interconnection, and the main breaker and busbar rating already carry a PV backfeed — so anything else you add (an EV charger, a heat pump) has to be checked against what is left under the 120% rule, not against the service size alone.
Recorded sales (1)
| Date | Price | Type |
|---|---|---|
| 2005-09-07 | $1,000,000 | Special Warranty Deed |
Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.
Most recent permit on record for this parcel: 2025-12-23 (TC-COM-1225-02310) — Added ventilation for warehouse..
Permit history (35)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2025-12-23expires 2026-08-26 | TC-COM-1225-02310City permit record | Commercial BuildingAdded ventilation for warehouse. | Issued | |
| 2025-04-03expired 2025-10-27 | TS-PRM-0425-00129City permit record | Fence / wallNEEDS JEDERS APPROVAL - bw 4/15 apprv $+inspec fixed - Install 3 illuminated wall signs and 1 non-illuminated wall sign | Issued | |
| 2024-11-26finaled | TC-CFO-1124-00232City permit record | Pool / spaPLEASE PAY TCO EXTENSION FEE UNDER TC-CFO-0924-00197. TCO WILL BE UPDATED TO LEVEL 4. IF ANOTHER TCO EXTENSION IS NEEDED PLEASE REQUEST UNDER TC-CFO-0924-00197 PRIOR TO EXPIRATION DATE 01/17/2025. Tenant improvement of existing warehouse space. New use consists of beer keg sanitation, storage and associated office spaces (F-2, S-2 & B). Type VB construction. Privately funded. | Complete | |
| 2024-11-07finaled | TC-CFO-1124-00225City permit record | Pool / spaPLEASE PAY TCO EXTENSION FEE UNDER TC-CFO-0924-00197. WHEN REQUESTING A TCO EXTENSION PLEASE REQUEST UNDER TC-CFO-0924-00197. Tenant improvement of existing warehouse space. New use consists of beer keg sanitation, storage and associated office spaces (F-2, S-2 & B). Type VB construction. Privately funded. | Complete | |
| 2024-10-14finaled | TC-CFO-1024-00211City permit record | Pool / spaPLEASE PAY TCO EXTENSION FEE UNDER TC-CFO-0924-00197. WHEN REQUESTING A TCO EXTENSION PLEASE REQUEST UNDER TC-CFO-0924-00197. Tenant improvement of existing warehouse space. New use consists of beer keg sanitation, storage and associated office spaces (F-2, S-2 & B). Type VB construction. Privately funded. | Complete | |
| 2024-09-13finaled | TC-CFO-0924-00197City permit record | Pool / spaTenant improvement of existing warehouse space. New use consists of beer keg sanitation, storage and associated office spaces (F-2, S-2 & B). Type VB construction. Privately funded. | Complete | |
| 2024-09-11 | TC-CFO-0924-00193City permit record | Pool / spaThis project requires Water Sterilization Report prior to TCO. Please login to your TDC account and submit approved Water Sterilization Report. Once condition is satisfied please re-request TCO. Any questions please email Building_official@tucsonaz.gov Tenant improvement of existing warehouse space. New use consists of beer keg sanitation, storage and associated office spaces (F-2, S-2 & B). Type VB construction. Privately funded. | Denied | |
| 2024-09-05finaled | TF-FCP-0924-00757City permit record | Fire ConstructionTie-in of new devices to existing fire alarm system | Complete |
Show 27 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2024-08-21 | TF-FCP-0824-00703City permit record | Fire ConstructionVOID-APPLIED FOR SPRINKLER PERMIT INSTEAD OF ALARM PERMIT - Tie-in of new devices to existing fire alarm system | Void | |
| 2024-08-05 | TR-UTL-0824-01457City permit record | Right-of-Way (ROW) - UtilityTrench 3', place 2-2" conduits, overlash 809' to existing Cox CATV for system tie on Alvernon | Void | |
| 2024-07-13finaled | TF-FCP-0724-00561City permit record | Fire ConstructionModify existing fire sprinkler system | Complete | |
| 2024-04-29expired 2024-06-02 | TC-CFO-0424-00092City permit record | Certificate of OccupancyBLDG 3 - a tenant finish for an existing one story single sided dock warehouse / distribution building | Issued | |
| 2024-04-10finaled | TR-UTL-0424-00751City permit record | Right-of-Way (ROW) - Utility(1) 3' x 6' bell hole in dirt along with an approx. 2' x 20' trench in dirt. Crews will be working along West shoulder, South bound side of the road to install new gas service. | Complete | |
| 2024-04-08finaled | TF-FOP-0424-00390City permit record | Fire OperationalHigh Pile Storage for Krosswood Doors | Complete | |
| 2024-03-18finaled | TS-PRM-0324-00118City permit record | Sign - Permanent(2) Sets of Metal Reverse Pan Channel Logo & Letters | Complete | |
| 2024-03-06finaled | TZ-CMP-0324-00030City permit record | Zoning Verification LetterPlease provide a Zoning Verification Letter with zone designation, abutting zones and permitted use. | Complete | |
| 2024-02-23finaled | TF-FCP-0224-00138City permit record | Pool / spaAdd 27 new sprinkler pendents to new office space in existing warehouse. | Complete | |
| 2024-02-21finaled | TC-COM-0224-00338City permit record | Pool / spaTenant improvement of existing warehouse space. New use consists of beer keg sanitation, storage and associated office spaces (F-2, S-2 & B). Type VB construction. Privately funded. | Complete | |
| 2024-01-18finaled | TC-CFO-0124-00026City permit record | Certificate of OccupancyNew construction of a 1 story warehouse distribution building. | Complete | |
| 2024-01-17expired 2025-02-25 | TC-COM-0124-00107City permit record | Commercial BuildingNew TEP transformer and a 4000amp SES install | Inspections | |
| 2023-11-18finaled | TC-COM-1123-02690City permit record | Commercial BuildingBLDG 3 - a tenant finish for an existing one story single sided dock warehouse / distribution building | Complete | |
| 2023-10-10finaled | TZ-CMP-1023-00188City permit record | Solar PVApplicant is is currently constructing its redevelopment of the subject property to include over 700,000 square feet of new Class A industrial development (the “Project”). The Project consists of three industrial buildings which are expected to attract a wide range of industrial, technology, manufacturing and logistics companies. Please note we would like this letter to contain affirmative language stating the following: 1. That the Property is located within the I-1 (Light Industrial) zoning classification; 2. The permitted uses thereunder, with specific confirmation that the use of the Property and structures located thereon (if any) is allowed under the current zoning; 3. That there is compliance with respect to (as applicable): a. Area, width, and depth of the land as a building site for the structures; b. Floor space area for the structures; c. Setback of said structure from property lines; d. Height of said structures; and e. Sufficient parking spaces. 4. That all conditions have been satisfied and an occupancy permit has been issued (if applicable); 5. That the Property is in compliance with all applicable subdivision, ordinances and regulations; and 6. Permitted uses under the current zoning, without the necessity of obtaining a rezoning, conditional use permit or variance, includes, but is not limited to: a. Receiving, storing, assembling, shipping, distributing, preparing, and selling products, materials, food, grocery and liquor items; b. The parking (including tandem parking), storage, and use (including driving into and through the building for loading and unloading and parking inside the building) of automobiles, trucks, machinery and trailers, including outdoor loading and unloading; c. Warehouse and office use; d. Using, handling or storing hazardous materials in accordance with applicable law and in the ordinary course of business, including (i) in any packaged merchandise to be sold, handled, and/or held for shipment to customers, (ii) maintenance of trucks and machinery, and (iii) batteries for any trucks, generators or other machinery or the equipment described in clause (e); e. Installing and operating rooftop equipment such as satellite dishes, cellular antenna, and renewable energy systems, including solar energy systems and related equipment; f. Installing and operating battery storage systems, and electrical generators; and g. Ancillary and related uses for any of the foregoing, all on a twenty-four-hour, seven-days-per-week, fifty-two-weeks-per-year basis. | Complete | |
| 2023-07-14finaled | TR-UTL-0723-02039City permit record | Right-of-Way (ROW) - UtilityWO T59217. TEP to work in/near ROW along East Palo Verde and South Valencia. TEP to complete riser installation and pull in primary cable for new service connection of Tucson Commerce Center. | Complete | |
| 2023-06-14 | TR-ROW-0623-00874City permit record | Right-of-Way (ROW)Resubmitting TR-ROW-0423-00627 Installing a 2" HDPE sewer force main between parcels 14041124C and 14041124E. We will install it using horizontal boring. Work is associated with dev packages DP22-0100 and DP22-0149 and Pima County Sewer permit number P22D00117. | Needs resubmittal | |
| 2023-05-05finaled | TF-FCP-0523-00672City permit record | Fire ConstructionNew underground fire line service for a 244,889 sqft warehouse | Complete | |
| 2023-05-02 | TE-FPU-0523-00190City permit record | Floodplain UseInstalling a 2" HDPE sewer force main between parcels 14041124C and 14041124E. We will install it using horizontal boring. Work is associated with dev packages DP22-0100 and DP22-0149 and Pima County Sewer permit number P22D00117. | In review | |
| 2023-04-12 | TR-ROW-0423-00627City permit record | Right-of-Way (ROW)Installing a 2" HDPE sewer force main between parcels 14041124C and 14041124E. We will install it using horizontal boring. Work is associated with dev packages DP22-0100 and DP22-0149 and Pima County Sewer permit number P22D00117. | Needs resubmittal | |
| 2023-03-31finaled | TR-ROW-0323-00583City permit record | Right-of-Way (ROW)Four waterline tie-ins associated with Dev Packages DP22-0100 and DP22-0149 and Tucson Water Permit P23PW00012. One tie-in on Palo Verde Rd and three tie-ins on Alvernon Way. | Complete | |
| 2023-03-24finaled | TR-PIA-0323-00013City permit record | Private Improvement Agreement (PIA)New 6' sidewalk along south side of Valencia between Palo Verde and Alvernon, plus new 5' sidewalk and curb along west side of Alvernon. | Complete | |
| 2023-02-28finaled | TR-ROW-0223-00443City permit record | Right-of-Way (ROW)Traffic Control setup for Installing new 6' sidewalk in Right-of-Way around perimeter of new development under approved PIA TR-PIA-0323-00013. | Complete | |
| 2022-12-20finaled | TF-FCP-1222-00217City permit record | Fire ConstructionProvide 7 complete wet-pipe sprinkler systems and 1,500 GPM electric fire pump | Complete | |
| 2022-12-07 | TD-DEV-1222-00068City permit record | Development Package"WITHDRAWN at applicant request" DP22-0149 | Withdrawn | |
| 2022-11-07 | TR-ROW-1122-00052City permit record | Right-of-Way (ROW)We will be performing the earthwork and installing underground utilities under Dev Plan DP22-0100 & DP22-0149 on parcels 140-41-1250, 140-41-124E, & 140-41-124C. Parcels 140-41-1250 & 140-41-124E are separated from 140-41-124C by Rodeo Wash, so we will need to cross over the wash with three 4-in HDPE lines in order to get construction water from hydrant meters to a temporary basin located on the parcel 140-41-124E north of the wash. We will also need to cross through the right-of-way on the east end of the site for access between parcels There will be no excavation or traffic impact involved in this right of way permit. | Needs resubmittal | |
| 2022-06-06finaled | DP22-0149City permit record | Development PackageSite/Grading/Swppp - Tucson Commerce Center, SOUTH side of Rodeo Wash. | Complete | |
| 2022-05-25finaled | T22CM04003City permit record | Commercial BuildingShell Bldg. | Complete |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (2)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2022-03-01 | T22DV01560Code enforcement case | Code enforcement case | Complian |
| 2015-07-14 | T15DV05099Code enforcement case | Code enforcement case | Complian |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Planning work at this property?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
Send: the permanent link and the summary above, once. Watch: one email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list either way.
How this report was built
This is a reading of public records for parcel 14041124C — 35 permits on file from 2022 to 2025 (7 pool / spa, 5 fire construction, 5 right-of-way (row), 4 commercial building) and 2 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.