Electrical permit history — 6525 S Country Club Rd
6525 S Country Club Rd, Tucson — built 1993, with 32 permits on record. Review electrical, HVAC and remodel history with links to official records.
Commercial property
6525 S Country Club Rd
Built 1993 — 1990s commercial stock · last permitted panel/service work 2012 (finaled); a newer 2021 permit is issued · HVAC 2010 (permit expired without a confirmed final)
Permanent link: Electrical permit history for 6525 S Country Club Rd (aztucsonelectricalsolutions.com/property/140410540/6525-s-country-club-rd-tucson-az-85756) · Public records last checked 2026-08-17
- Parcel
- 140410540
- Built
- 1993 (county record)
- Jurisdiction
- Tucson
- Zoning
- C-2
- Assessor use
- Convenience Store With Fuel Dispensing
- Parcel size
- 1.04 acres
- Building area
- 2,979 sq ft (assessor record)
- Sewer
- Connection on file (2013) (county sewer connection records)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
- Service on record
- City records show the 2012 permit was finalized; the permit description states “ZONING COMPLIANCE: ADD TEMP SOIL VAPOR EXTRACTION EQUIPMENT AND 6' HIGH CHAIN LINK FENCE. NEW 200 AMP ELECTRIC CONNECTION.”.
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionCurrentA newer 2021 permit for the same system is recorded as “Issued” — The work was permitted, but final completion is not confirmed. The permit description states “Upgrade electrical to 800Amp, 3PH, 120/208V at existing Circle K convenience store.”. Last permitted 2012 (14 years ago). City inspection record: ELECTRIC - FINAL approved 2013-06-06. Worth reading the permit itself: it names the service but does not read as an increase in capacity, so this may have been a like-for-like replacement rather than an upgrade. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. T12CM06782 — ZONING COMPLIANCE: ADD TEMP SOIL VAPOR EXTRACTION EQUIPMENT AND 6' HIGH CHAIN LINK FENCE. NEW 200 AMP ELECTRIC CONNECTION.
- Heating, cooling & mechanicalPermitted — completion not confirmedA 2010 permit specifies this work (the permit description states “REPLACE; TWO- 5 TON ROOFTOP AC/HEAT PUMPS (APA)”), but the available record does not show a final inspection. The permit expired without a confirmed final status. Official status: Expired. Contractor of record: CONTEMPORARY REFRIGERATION INC *C. T10CM02667 — REPLACE; TWO- 5 TON ROOFTOP AC/HEAT PUMPS (APA)
- Fire alarm & life safetyPermitted — completion not confirmedA 2024 permit specifies this work (the permit description states “Installation of a CO2 detection system for the BIB racks and the soda machines”), but the available record does not show a final inspection. The work was permitted, but final completion is not confirmed. Official status: Issued. TF-FCP-1224-01025 — Installation of a CO2 detection system for the BIB racks and the soda machines
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check
Gear in this age range is usually still supported but is due for infrared scanning and torque verification if that has not been done recently. The permit record does not confirm this; an on-site inspection is required.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
Most recent permit on record for this parcel: 2024-12-03 (TF-FCP-1224-01025) — Installation of a CO2 detection system for the BIB racks and the soda machines.
Permit history (32)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2024-12-03expired 2025-06-09 | TF-FCP-1224-01025City permit record | Fire ConstructionInstallation of a CO2 detection system for the BIB racks and the soda machines | Issued | |
| 2024-12-03expired 2025-12-09 | TF-FOP-1224-01445City permit record | Fire OperationalInstallation of CO2 monitoring system for the BIB rack and soda machine | Fees paid | |
| 2024-01-14 | TC-COM-0124-00084City permit record | Commercial BuildingInterior merchandising modification and maintenance program to the existing facility floor plan, no sf area increase to building footprint, no structural modifications, no modifications to exterior facade, site, fuel canopy, fuel pumps or signage. | Approved - awaiting customer attention | |
| 2022-11-22finaled | TR-UTL-1122-00309City permit record | Right-of-Way (ROW) - UtilityCox to Overlash 1159' of aerial to existing cox lines, trench 67' and bore 449' to install CATV conduit and place vaults for system tie. | Complete | |
| 2022-07-01finaled | T22RW02380City permit record | Right-of-Way (ROW)Cox to overlash 1528ft of aerial 288ct fiber for system tie.** PROOF OF NOTIFICATION IS REQUIRE; Work Order: PRJ223984-1 | Complete | |
| 2021-04-19expired 2024-08-10 | T21CM03297City permit record | Commercial BuildingUpgrade electrical to 800Amp, 3PH, 120/208V at existing Circle K convenience store. | Issued | |
| 2020-06-02finaled | T20RW03147City permit record | ROWStarting on the South side of E. Valencia and East of S. Country Club, Riser up and Overlash going West 222' Riser down and trench/bore going South 25' to out of ROW. OTHER ACTIVITIES IN THE AREA, WILL NEED TO COORDINATE TRAFFIC CONTROL SETUP WITH EXISTING SETUP. BUS STOP IN THE AREA, CONTACT SUN TRAN, BEA PAULUS AT 520-206-8826 AND/OR CHRISTINA ROCK AT 520-206-8934 24-HOURS PRIOR TO START OF WORK FOR COORDINATION. | Final | |
| 2018-05-03finaled | T18RW02001City permit record | ROWN.345029 - PART ONE WORK SCOPE: CENTURYLINK REQUESTS PERMISSION TO ACCESS THREE MANHOLES FOR FIBER OPTIC SPLICING ONLY. NO EXCAVATION WORK . | Final |
Show 24 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2018-03-21 | T18CM02118City permit record | COMBOINSTALL ILLUMINATED FASCIA ON 3 SIDES OF CANOPY | Withdrwn | |
| 2017-10-25finaled | T17OT01101City permit record | Fence / wall5 - ILLUM SIGNS ( 3 WALL + 2 CofC DF) | Final | |
| 2017-08-02finaled | T17RW03329City permit record | ROWINSTALL NEW 22' X 5' X 6" DEEP CONCRETE PAD BEHIND SIDEWALK INSTALL NEW 18' SAGUARO-STYLE SHELTER PAD # 45 TC # 1 | Final | |
| 2017-02-23finaled | T17FO00154City permit record | FIREOPERFLAMMABLE LIQUIDS USED IN FUEL DISPENSING | Final | |
| 2016-09-08finaled | T16CM06912City permit record | COMBOREPL OUTDOOR LIGHTING | Final | |
| 2013-09-04expired 2014-03-25 | T13BU01008City permit record | TANKSRELINE INTERIOR OF UNDERGROUND TANKS | Expired | |
| 2013-04-04expired 2013-10-19 | T13CM01945City permit record | COMBOTI: CIRCLE K | Expired | |
| 2013-04-03expired 2013-10-02 | T13OT00399City permit record | SIGNREPAIR OF EXISTING DF SIGNS 21141 | Expired | |
| 2012-10-24finaled | T12CM06782City permit record | Fence / wallZONING COMPLIANCE: ADD TEMP SOIL VAPOR EXTRACTION EQUIPMENT AND 6' HIGH CHAIN LINK FENCE. NEW 200 AMP ELECTRIC CONNECTION. | Final | |
| 2011-11-03finaled | T11BU01456City permit record | TANKSUNDERGROUND TANKS | Final | |
| 2010-11-10expired 2011-05-09 | T10BU01690City permit record | TANKSREPAIR UNDERGROUND FUEL TANK | Expired | |
| 2010-09-23expired 2011-05-16 | T10CM02667City permit record | COMBOREPLACE; TWO- 5 TON ROOFTOP AC/HEAT PUMPS (APA) | Expired | |
| 2009-06-19expired 2009-12-16 | T09BU00894City permit record | TANKSFUEL TANK REPAIR | Expired | |
| 2008-04-07finaled | T08BU00661City permit record | TANKSREPLACE: 4 EXSISTING DISPENSERS AT GAS STATION FOR 4 NEW DISPENSERS | Final | |
| 2007-05-01finaled | T07OT01029City permit record | SIGN13044 | Final | |
| 2006-11-30finaled | T06OT03103City permit record | SIGN12269 | Final | |
| 2006-10-06finaled | T06OT02610City permit record | SIGN11949 | Final | |
| 2006-08-22finaled | T06OT02207City permit record | SIGN11703 | Final | |
| 2005-08-23expired 2009-01-25 | T05CM04395City permit record | COMBOREPLACE: ELECTRICAL AND MECHANICAL EQUIPMENT | Closed | |
| 2004-07-02finaled | T04OT01323City permit record | SIGNSIGN:7396 | Final | |
| 2002-09-09finaled | T02OT01420City permit record | SIGNSIGN:4462 | Final | |
| 1997-11-18finaled | T97ME00470City permit record | MECHHEAT PUMPS:REPLACEMENT | Final | |
| 1997-11-12finaled | T97EL01890City permit record | ELECTTI:FACIA LIGHTING | Final | |
| 1997-10-10expired 1998-04-19 | T97BU02085City permit record | Addition / alterationADDITION:TRASH ENCLOSURE | Expired |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (6)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2023-06-08 | CE-VIO0623-03970Code enforcement case | Code enforcement case | Closed - resolved |
| 2017-10-09 | T17DV05206Code enforcement case | Code enforcement case | Complian |
| 2010-08-19finaled | T10FR01781Code enforcement case | Code enforcement case | Complete |
| 2009-10-21finaled | T09FR03334Code enforcement case | Fire | Complete |
| 2009-08-12finaled | T09FR02663Code enforcement case | Code enforcement case | Complete |
| 2008-04-10finaled | T08FR00910Code enforcement case | Code enforcement case | Complete |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Planning work at this property?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, sent once. No list.One email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list.
How this report was built
This is a reading of public records for parcel 140410540 — 32 permits on file from 1997 to 2024 (7 sign, 5 combo, 5 tanks, 3 row) and 6 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.