Electrical permit history — 3690 E Hemisphere Lp
3690 E Hemisphere Lp, Tucson — built 2008, with 35 permits on record. Review electrical, HVAC and remodel history with links to official records.
Commercial property
3690 E Hemisphere Lp
Built 2008 — 2000s commercial stock · 35 permits on record; no permitted panel/service or HVAC work among them
Permanent link: Electrical permit history for 3690 E Hemisphere Lp (aztucsonelectricalsolutions.com/property/14029212b/3690-e-hemisphere-lp-tucson-az-85706) · Public records last checked 2026-08-16
- Parcel
- 14029212B
- Built
- 2008 (county record)
- Jurisdiction
- Tucson
- Zoning
- I-1
- Assessor use
- Day Care/Pre-School Ctr Private Children
- Parcel size
- 3.70 acres
- Building area
- 25,339 sq ft (assessor record)
- Sewer
- Connection on file (2014) (county sewer connection records)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 fire operational permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
- Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 fire operational permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
- Fire alarm & life safetyCurrentA newer 2020 permit for the same system is recorded as “Expired” — The permit expired without a confirmed final status. The permit description states “Fire Alarm & Detection Systems - ADT Monitoring takeover of existing; Fire Alarm Systems - Monitoring Modification”. Last permitted 2014 (12 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T14BU00366 — RELOCATE 4 FIRE SPRINKLER HEADS
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check
A capacity and condition review is the usual starting point before any tenant improvement or added load. The permit record does not confirm this; an on-site inspection is required.
Recorded sales (3)
| Date | Price | Type |
|---|---|---|
| 2013-05-21 | $8,450,000 | Warranty Deed |
| 2007-04-12 | $840,000 | Warranty Deed |
| 2003-06-30 | $443,985 | Special Warranty Deed |
Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.
Most recent permit on record for this parcel: 2025-12-16 (TF-FOP-1225-01643) — This is a child care facility licensed in the State of Arizona for children 6 Weeks to 12 years..
Permit history (35)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2025-12-16finaled | TF-FOP-1225-01643City permit record | Fire OperationalThis is a child care facility licensed in the State of Arizona for children 6 Weeks to 12 years. | Complete | |
| 2024-10-15finaled | TF-FOP-1024-01183City permit record | Fire OperationalThis is the annual permit for a child care center that operates Monday through Friday. | Complete | |
| 2023-08-18finaled | TF-FOP-0823-01396City permit record | Fire OperationalChildcare center | Complete | |
| 2022-10-06finaled | T22FO00860City permit record | Addition / alterationState Lic Facls Annual Insp - 380 PERSONS; Care or Preschool - # of Persons: 0; Additional Inspections: 1 | Complete | |
| 2021-03-17finaled | T21RW01263City permit record | ROWPothole needed to complete locate. 2 5x5 bellholes in black top / dirt front to pothole gas line. | Final | |
| 2020-10-22finaled | T20FO00543City permit record | FIREOPERCHILDRENS LEARNING CENTER | Final | |
| 2020-05-07expired 2021-05-14 | T20FC00303City permit record | Fire ConstructionFire Alarm & Detection Systems - ADT Monitoring takeover of existing; Fire Alarm Systems - Monitoring Modification | Expired | |
| 2019-03-04finaled | T19FO00169City permit record | FIREOPERDaycare | Final |
Show 27 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2019-02-04finaled | T19CM00855City permit record | COMBOLIKE FOR LIKE WATER HEATER REPL | Final | |
| 2014-04-04finaled | T14BU00366City permit record | SPKLRRELOCATE 4 FIRE SPRINKLER HEADS | Final | |
| 2014-01-28finaled | T14CM00557City permit record | COMBOTI: CHILD CARE | L of c | |
| 2011-12-13finaled | T11OT02281City permit record | SIGNBANNER 90 DAYS START: 12/12/11 END: 03/11/12 | Final | |
| 2011-12-13expired 2012-09-09 | T11OT02282City permit record | SIGNPENNANTS 90 DAYS START: 12/12/11 END: 03/11/12 | Expired | |
| 2010-09-15finaled | T10OT01987City permit record | SIGN18887 ILLEGAL PENNANTS | Final | |
| 2010-06-24finaled | T10OT01383City permit record | SIGN18567 | Final | |
| 2010-04-08finaled | T10OT00775City permit record | SIGN18164 | Final | |
| 2009-11-18finaled | T09OT02482City permit record | SIGN17493 | Final | |
| 2009-10-06expired 2009-12-05 | T09EX00568City permit record | EXCAVPLACE +/- 330' OF 6' WIDE SIDEWALK ALONG PROPERTY FRONTAGE ON VALENCIA RD | Closed | |
| 2009-06-05finaled | T09OT01144City permit record | SIGN16775 | Final | |
| 2009-02-19expired 2009-04-20 | T09EX00108City permit record | EXCAVINSTALL 2 35' WIDE DRIVEWAY ENTRANCES WITH CURB RETURNS AND CURB ACCESS RAMPS WITH TRUNCATED DOMES AS THE TACTILE WARNING DEVICE ALONG HEMISPHERE LOOP. PER APPRV GRADING PLAN T08BU00043 | Closed | |
| 2009-02-03finaled | T09OT00223City permit record | SIGN16248 | Final | |
| 2009-01-07finaled | T09BU00011City permit record | BUILD2 SHADE STRUCTURES (1050 SF AND 1980 SF)) | Final | |
| 2008-11-25finaled | T08BU02060City permit record | SPKLRInstall 115' of 4" fire service underground | Final | |
| 2008-11-07 | T08OT02647City permit record | SIGN15811 | Withdrwn | |
| 2008-11-05expired 2009-05-05 | T08OT02616City permit record | SIGN15857 | Withdrwn | |
| 2008-10-30finaled | T08BU01933City permit record | BUILDINSTALL: NEW FIRE ALARM SYSTEM | Final | |
| 2008-10-28finaled | T08OT02555City permit record | SIGN15811 | Final | |
| 2008-10-23finaled | T08BU01891City permit record | SPKLRInstall 510 fire sprinklers | Final | |
| 2008-10-06expired 2008-12-05 | T08EX00820City permit record | EXCAVEXCAVATION OF 50' IN PAVEMENT TO INSTALL ELECTRIC | Closed | |
| 2008-09-08expired 2008-11-07 | T08EX00723City permit record | EXCAVTRENCHING 32'P & 33'B IN SIDEWALK AREA | Closed | |
| 2008-08-14finaled | T08OT01924City permit record | SIGN15442 | Final | |
| 2008-01-18finaled | T08BU00093City permit record | GRADINGGRADING - TUTOR TIME - D07-0006 | Final | |
| 2007-08-23 | T07AN00703City permit record | ADDRNEW | Issued | |
| 2007-08-23finaled | T07CM03497City permit record | COMBONEW CHILDCARE REVISION 4: VARIOUS CHANGES ON MOST OF ALL DOCUMENTS | C of o | |
| 2007-02-01 | D07-0006City permit record | Development PackageTUTOR TIME DAYCARE | Approved |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (4)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2024-05-17 | CE-VIO0524-01871Code enforcement case | Vegetation | Closed - resolved |
| 2023-08-04 | CE-VIO0823-04967Code enforcement case | Vegetation | Closed - resolved |
| 2013-05-09 | T13DV03214Code enforcement case | Code enforcement case | Noverify |
| 2007-08-21 | T07DV07965Code enforcement case | Vegetation | Complian |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, once. No list, no follow-up unless you ask for it.
How this report was built
This is a reading of public records for parcel 14029212B — 35 permits on file from 2007 to 2025 (12 sign, 4 excav, 3 fire operational, 3 combo) and 4 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.