Electrical permit history — 3601 E Britannia Dr

3601 E Britannia Dr, Tucson — built 2008, with 15 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

3601 E Britannia Dr

Built 2008 — 2000s commercial stock · HVAC 2025 (permitted, completion not confirmed)

Parcel
14029207A
Built
2008 (county record)
Jurisdiction
Tucson
Zoning
I-1
Assessor use
Office Building 2 Story
Parcel size
7.51 acres
Building area
56,800 sq ft (assessor record)
Sewer
No connection on file (sewer or septic status not confirmed by the record — verify on site)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 3601 E Britannia Dr, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2008 build permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalPermitted — completion not confirmedA 2025 permit specifies this work (the permit description states “REPLACE EXISTING WATER COOLED CHILLER WITH NEW. REPLACE EXISTING REFRIGERANT MONITOR SYSTEM WITH NEW.”), but the available record does not show a final inspection. The work was permitted, but final completion is not confirmed. Official status: Issued. TC-COM-0525-00876 — REPLACE EXISTING WATER COOLED CHILLER WITH NEW. REPLACE EXISTING REFRIGERANT MONITOR SYSTEM WITH NEW.
  • Fire alarm & life safetyCurrentA newer 2019 permit for the same system is recorded as “Expired” — The permit expired without a confirmed final status. The permit description states “Fire Alarm & Detection Systems - As-Built - Primary Company has installed CO2 Monitor; Fire Alarm Systems - Devices Modified: 5”. Last permitted 2019 (7 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T19FC00186 — INSTALL A SMOKE DETECTOR AND A HORN/STROBE IN THE NEW UPS ROOM- CONNECT TO THE EXISTING FACP.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Routine

    Office and medical tenant improvements are usually limited by available panel spaces and branch circuit capacity, not by the service itself.

Recorded sales (2)

Recorded transfers from the Pima County Assessor — 2 of 2
DatePriceType
2019-01-09$12,450,000Warranty Deed
2007-01-30$1,247,516

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2025-05-01 (TC-COM-0525-00876) — REPLACE EXISTING WATER COOLED CHILLER WITH NEW. REPLACE EXISTING REFRIGERANT MONITOR SYSTEM WITH NEW..

Permit history (15)

Permit history for this parcel — 8 of 15 records
DateRecordWhatStatusValue
2025-05-01expired 2026-03-09TC-COM-0525-00876City permit recordCommercial BuildingREPLACE EXISTING WATER COOLED CHILLER WITH NEW. REPLACE EXISTING REFRIGERANT MONITOR SYSTEM WITH NEW.Issued
2021-03-11finaledT21RW01154City permit recordROWW/O# 2102576 - COMPLETE PERMANENT PATCH AFTER SERVICE REPAIR @ 5 LF.Final
2020-05-21finaledT20RW02923City permit recordROW20R1217 - REPAIR LEAKING 2" SERVICE LINE @ 10 LF IN ASPHALT EMERGENCY - AFTER THE FACT PERMITFinal
2019-04-16expired 2020-04-28T19FC00279City permit recordFire ConstructionFire Alarm & Detection Systems - As-Built - Primary Company has installed CO2 Monitor; Fire Alarm Systems - Devices Modified: 5Expired
2019-03-11finaledT19FC00186City permit recordFIRECONSINSTALL A SMOKE DETECTOR AND A HORN/STROBE IN THE NEW UPS ROOM- CONNECT TO THE EXISTING FACP.Final
2018-12-19expired 2019-10-07T18CM09859City permit recordCOMBOTI:OFFICEExpired
2018-07-26finaledT18RW03295City permit recordROWN.379751 - . MH accesses, change out (1) 1248 ped to Charles ped, change out (3) existing peds to UPC1850 peds. MH #16801 and MH #18211.Final
2008-08-25finaledT08BU01563City permit recordBUILDFIRE ALARM SYSTEMFinal
Show 7 older records
Permit history for this parcel — remaining 7 records
DateRecordWhatStatusValue
2008-04-17expired 2008-06-16T08EX00326City permit recordEXCAVTRENCH 26'D (RELOCATE FIRE HYDRANT)Closed
2008-04-15finaledT08BU00730City permit recordBUILDFIRE ALARM FOR PRE-ACTION SYSTEMFinal
2008-04-10finaledT08BU00702City permit recordSPKLRInstall 560 fire sprinklersFinal
2008-03-17finaledT08CM00874City permit recordCOMBOTEMP CONSTRUCTION TRAILERFinal
2008-02-27finaledT08BU00382City permit recordSPKLR245 feet of 8 inch fire underground.Final
2008-01-29expired 2008-05-09T08EX00084City permit recordEXCAVEXCAVATION OF 200' TO INSTALL TWO 24' WIDE DRIVEWAY OPENINGS, TWO 16' WIDE DRIVEWAY OPENINGS, ONE 30' WIDE DRIVEWAY OPENING ALONG WITH EIGHT CURB ACCESS RAMPS WITH TRUNCATED DOMES. ALL READIUS RETURNS TO BE 18'Closed
2007-05-11D07-0022City permit recordDevelopment PackageDAVIS SELECTED ADVISERSApproved

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (1)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 1 of 1 records
DateRecordWhatStatus
2008-07-31T08DV06581Code enforcement caseVegetationNoverify

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 14029207A — 15 permits on file from 2007 to 2025 (3 row, 2 combo, 2 build, 2 excav) and 1 code enforcement case — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.