Electrical permit history — 3675 E Britannia Dr

3675 E Britannia Dr, Tucson — built 2004, with 36 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

3675 E Britannia Dr

Built 2004 — 2000s commercial stock · last permitted panel/service work 2004 (finaled); a newer 2016 permit is expired without a final · HVAC 2016 (finaled)

Parcel
140292040
Built
2004 (county record)
Jurisdiction
Tucson
Zoning
I-1
Assessor use
Federal Industrial Property
Parcel size
2.66 acres
Building area
81,225 sq ft (assessor record)
Sewer
No connection on file (sewer or septic status not confirmed by the record — verify on site)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)
Service on record
City records show the 2004 permit was finalized; the permit description states “WAREHOUSE:NEW SHELL 225'4" x 361'4" CONCRETE TILT-UP BUILDING W/ INTERIOR STEEL STRUCTURE, STEEL ROOF JOISTS AND STEEL ROOF DECKING, ONE-HOUR FIRE-RATED WALL SEPARATING SES ROOM AND WAREHOUSE REVISION FOR SHOP DRAWINGS : SHOP DRAWINGS APPROVED FOR:1. TILT-UP WALLS,2. STRUCTURAL STEEL,3. METAL ROOF DECKING,4. METAL ROOF JOISTS ,5. STEEL LADDER ,6. ROOF LATCH. REVISION FOR LOADING DOCK AND CANOPY : (10/26/04) PROVIDE SHOP DRAWINGS FOR CANOPY STEEL , METAL DECKING , HANDRAILS AND GUARDRAILS SHOP DRAWINGS SUBMITTED FOR LOADING DOCK GUARDRAIL, DOCK HANDRAIL, GUARDRAIL, CANOPY FRAMING, COLUMNS, CANOPY BEAMS, (12/9/04) (12/30/04) LOADING DOCK SHOP DRAWINGS FOR : 1. CANOPY METAL DECKING, 2. CANOPY STEEL FRAMING, 3.GUARDS ,4. HANDRAILS.”.

See the property

County aerial photograph centered on 3675 E Britannia Dr, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionCurrentA newer 2016 permit for the same system is recorded as “Expired” — The permit expired without a confirmed final status. The permit description states “10 LF FRONT SOUTHWEST CORNER OF LOT; SERVICE LINE REPLACEMENT WORK ORDER # 1615320”. Last permitted 2004 (22 years ago). City inspection record: NPPO - FINAL approved 2005-01-10. Contractor of record: OPUS SOUTHWEST CONSTRUCTION CORP. Worth reading the permit itself: it names the service but does not read as an increase in capacity, so this may have been a like-for-like replacement rather than an upgrade. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. T04CM01811 — WAREHOUSE:NEW SHELL 225'4" x 361'4" CONCRETE TILT-UP BUILDING W/ INTERIOR STEEL STRUCTURE, STEEL ROOF JOISTS AND STEEL ROOF DECKING, ONE-HOUR FIRE-RATED WALL SEPARATING SES ROOM AND WAREHOUSE REVISION FOR SHOP DRAWINGS : SHOP DRAWINGS APPROVED FOR:1. TILT-UP WALLS,2. STRUCTURAL STEEL,3. METAL ROOF DECKING,4. METAL ROOF JOISTS ,5. STEEL LADDER ,6. ROOF LATCH. REVISION FOR LOADING DOCK AND CANOPY : (10/26/04) PROVIDE SHOP DRAWINGS FOR CANOPY STEEL , METAL DECKING , HANDRAILS AND GUARDRAILS SHOP DRAWINGS SUBMITTED FOR LOADING DOCK GUARDRAIL, DOCK HANDRAIL, GUARDRAIL, CANOPY FRAMING, COLUMNS, CANOPY BEAMS, (12/9/04) (12/30/04) LOADING DOCK SHOP DRAWINGS FOR : 1. CANOPY METAL DECKING, 2. CANOPY STEEL FRAMING, 3.GUARDS ,4. HANDRAILS.
  • Heating, cooling & mechanicalCurrentLast permitted 2016 (10 years ago). City inspection record: MECHANICAL - FINAL approved 2016-12-02. Contractor of record: CHESTNUT BUILDING & DESIGN INC. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. T16CM02449 — ADD HVAC AND ELEC LOAD CAPACITY IN TELEPHONE ROOM
  • Fire alarm & life safetyCurrentLast permitted 2024 (2 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. TF-FCP-1124-01003 — Fire sprinkler system
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    Industrial and warehouse space usually means three-phase motor loads. High-bay LED retrofits and added VFDs both change the load picture.

Recorded sales (2)

Recorded transfers from the Pima County Assessor — 2 of 2
DatePriceType
2005-05-11$8,375,000Special Warranty Deed
2004-05-05$445,896Special Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2025-07-07 (TR-UTL-0725-01082) — Scope Revision - P.291606 - Bore 784', Trench 76', Dog 6 Pits, Place 4 New HH's/PEDS, Remove/Replace 40 SQFT of Asphalt, Remove/Replace 32 SQFT of Concrete, and Access HH 19871 for Splicing ( 9/29/2025 Updated) Original Scope - P.291606 - BORE 774', DIG 4 PITS, REMOVE/ REPLACE PED WITH BIGSHOT PED & PLACE 2 NEW HHs, & ACCESS HH 19871 & HH 21592 FOR SPLICING 9/3/25- RENEWAL FOR 90 DAYS AS OF 9/7/25. NEW EXPIRATION DATE IS 12/8/25 10/24/2025 - Per Revision Narrative - Adding existing MH 16801 & MH 18211 access for fiber optic splicing only.

Permit history (36)

Permit history for this parcel — 8 of 36 records
DateRecordWhatStatusValue
2025-07-07finaledTR-UTL-0725-01082City permit recordRight-of-Way (ROW) - UtilityScope Revision - P.291606 - Bore 784', Trench 76', Dog 6 Pits, Place 4 New HH's/PEDS, Remove/Replace 40 SQFT of Asphalt, Remove/Replace 32 SQFT of Concrete, and Access HH 19871 for Splicing ( 9/29/2025 Updated) Original Scope - P.291606 - BORE 774', DIG 4 PITS, REMOVE/ REPLACE PED WITH BIGSHOT PED & PLACE 2 NEW HHs, & ACCESS HH 19871 & HH 21592 FOR SPLICING 9/3/25- RENEWAL FOR 90 DAYS AS OF 9/7/25. NEW EXPIRATION DATE IS 12/8/25 10/24/2025 - Per Revision Narrative - Adding existing MH 16801 & MH 18211 access for fiber optic splicing onlyComplete
2025-05-20expired 2025-12-19TR-ROW-0525-00690City permit recordRight-of-Way (ROW)CONTINUATION OF PERMIT TR-ROW-0325-00302. We need to cross the road to the south with electrical conduits for a new parking lot across the street. one trench across the road with multiple conduits in it.Inspections
2025-03-03expired 2025-05-16TR-ROW-0325-00302City permit recordRight-of-Way (ROW)We need to cross the road to the south with electrical conduits for a new parking lot across the street. one trench across the road with multiple conduits in it.Inspections
2025-01-20finaledTF-FCP-0125-00044City permit recordFire ConstructionTenant ImprovementComplete
2025-01-07expired 2025-02-18TF-FOP-0125-00024City permit recordFire OperationalVOID - Customer decided to go with another company - Tent - 40x80Void
2024-11-25finaledTF-FCP-1124-01003City permit recordFire ConstructionFire sprinkler systemComplete
2023-05-25finaledTF-FCP-0523-00716City permit recordFire ConstructionReplacement of fire alarm control panel and annunciatorComplete
2019-07-08finaledT19FC00516City permit recordFIRECONSMODIFYING AN EXISTING FIRE ALARM PANELFinal
Show 28 older records
Permit history for this parcel — remaining 28 records
DateRecordWhatStatusValue
2019-02-25finaledT19FC00148City permit recordFIRECONSMODIFY EXISTING WET PIPE FIRE SPRINKLER SYSTEMFinal
2018-06-15finaledT18CM04687City permit recordAddition / alterationTI: WAREHOUSE/OFFICE MEZZANINE ADDITIONL of c
2016-10-05expired 2016-11-06T16RW01863City permit recordROW10 LF FRONT SOUTHWEST CORNER OF LOT; SERVICE LINE REPLACEMENT WORK ORDER # 1615320Expired
2016-10-04expired 2017-04-18T16CM07566City permit recordCOMBOSTEEL COVERED PARKING; COMMExpired
2016-04-04finaledT16CM02449City permit recordCOMBOADD HVAC AND ELEC LOAD CAPACITY IN TELEPHONE ROOMFinal
2014-11-25finaledT14BU01316City permit recordBUILDFIRE ALARM-TIFinal
2014-09-30finaledT14BU01081City permit recordSPKLRRELOCATE HEADFinal
2014-09-05finaledT14BU00994City permit recordSPKLRADD 3 FIRE SPRINKLERSFinal
2014-08-25finaledT14CM05545City permit recordCOMBOTI: OFFICE/WAREHOUSEL of c
2014-07-31finaledT14CM04879City permit recordCOMBOUPGRADE 800A UPS SYSTEML of c
2012-04-13expired 2012-12-17T12CM01909City permit recordCOMBOTI: LOBBYExpired
2012-03-06finaledT12BU00314City permit recordSPKLRAdd 4 fire sprinklersFinal
2010-09-09finaledT10CM02518City permit recordCOMBOTI:2 ROOFTOP A/C UNITSFinal
2009-03-06expired 2010-05-09T09CM00503City permit recordCOMBOTI:STEEL FRAME FOR EXHAUST FANClosed
2007-04-12expired 2009-09-12T07CM01517City permit recordCOMBOINSTALL:A/C UNITClosed
2006-11-28finaledT06BU02779City permit recordBUILDFIRE ALARMFinal
2006-09-14finaledT06BU02281City permit recordSPKLRADD 104 NEW FIRE SPRINKLERSFinal
2006-05-30finaledT06CM03229City permit recordCOMBOINSTALL: RACKING FOR PALLETSFinal
2005-11-07finaledT05CM05619City permit recordCOMBOSERVICE:ELECTRIC FOR NEW CONVEYOR SYSTEMFinal
2005-03-15finaledT05BU00606City permit recordBUILDFORKLIFT RAMP AT LOADING DOCK 6' x 17' REINFORCED CONCRETE RAMP W/GUARDSFinal
2004-12-22expired 2005-02-20T04EX01169City permit recordEXCAVEXCAV:MODIFY STORMDRAINClosed
2004-10-27finaledT04BU02620City permit recordSPKLRFIRE SPKR:RELOCATE 191Final
2004-10-25finaledT04BU02600City permit recordSPKLRFIRE SPKR:ADD 928Final
2004-08-23finaledT04BU02092City permit recordSPKLRFIRE SPKR:INSTALL 100LF OF 8" PIPEFinal
2004-07-27finaledT04CM03459City permit recordCOMBOTI:OFFICEC of o
2004-04-21finaledT04BU00960City permit recordGRADINGGRADING:Final
2004-04-21finaledT04CM01811City permit recordFence / wallWAREHOUSE:NEW SHELL 225'4" x 361'4" CONCRETE TILT-UP BUILDING W/ INTERIOR STEEL STRUCTURE, STEEL ROOF JOISTS AND STEEL ROOF DECKING, ONE-HOUR FIRE-RATED WALL SEPARATING SES ROOM AND WAREHOUSE REVISION FOR SHOP DRAWINGS : SHOP DRAWINGS APPROVED FOR:1. TILT-UP WALLS,2. STRUCTURAL STEEL,3. METAL ROOF DECKING,4. METAL ROOF JOISTS ,5. STEEL LADDER ,6. ROOF LATCH. REVISION FOR LOADING DOCK AND CANOPY : (10/26/04) PROVIDE SHOP DRAWINGS FOR CANOPY STEEL , METAL DECKING , HANDRAILS AND GUARDRAILS SHOP DRAWINGS SUBMITTED FOR LOADING DOCK GUARDRAIL, DOCK HANDRAIL, GUARDRAIL, CANOPY FRAMING, COLUMNS, CANOPY BEAMS, (12/9/04) (12/30/04) LOADING DOCK SHOP DRAWINGS FOR : 1. CANOPY METAL DECKING, 2. CANOPY STEEL FRAMING, 3.GUARDS ,4. HANDRAILS.Final
2004-01-29T04AN00083City permit recordADDRNEWIssued

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (1)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 1 of 1 records
DateRecordWhatStatus
2006-03-03T06FR00275Code enforcement caseCode enforcement caseField

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 140292040 — 36 permits on file from 2004 to 2025 (11 combo, 7 spklr, 3 fire construction, 3 build) and 1 code enforcement case — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.