Electrical permit history — 6161 S Palo Verde Rd

6161 S Palo Verde Rd, Tucson — built 1996, with 32 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

6161 S Palo Verde Rd

Built 1996 — 1990s commercial stock · last permitted panel/service work 2001 (finaled)

Parcel
14029052C
Built
1996 (county record)
Jurisdiction
Tucson
Zoning
I-1
Assessor use
Warehousing
Parcel size
4.90 acres
Building area
128,941 sq ft (assessor record)
Sewer
No connection on file (sewer or septic status not confirmed by the record — verify on site)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)
Service on record
City records show the 2001 permit was finalized; the permit description states “NEW SERVICE: T0 3000AMP”.

See the property

County aerial photograph centered on 6161 S Palo Verde Rd, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionCurrentLast permitted 2001 (25 years ago). City inspection record: ELECTRIC - FINAL approved 2001-08-16. Applicant on the permit: ENCOMPASS ELECTRIC. Worth reading the permit itself: it names the service but does not read as an increase in capacity, so this may have been a like-for-like replacement rather than an upgrade. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. T01EL01620 — NEW SERVICE: T0 3000AMP
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2003 spklr permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyCurrentA newer 2018 permit for the same system is recorded as “Expired” — The permit expired without a confirmed final status. The permit description states “Fire Alarm & Detection Systems - INSTALL NEW SPRINKLER MONITORING SYSTEM; Fire Alarm Systems - Monitor Only”. Last permitted 2018 (8 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T18FC00678 — ADD NEW 500 GALLON DOUBLE WALL TANK WITH OUTSIDE FILL AND VENTING PER IFC 2018
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    Gear in this age range is usually still supported but is due for infrared scanning and torque verification if that has not been done recently. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

Recorded sales (4)

Recorded transfers from the Pima County Assessor — 4 of 4
DatePriceType
2018-12-19$10,025,000Warranty Deed
2014-12-22$7,742,820Warranty Deed
2007-10-09$9,850,000Warranty Deed
2004-03-01$5,833,733Special Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2025-07-18 (TR-UTL-0725-01160) — Cox to proof/pull fiber for 920' for catv commercial business tie.

Permit history (32)

Permit history for this parcel — 8 of 32 records
DateRecordWhatStatusValue
2025-07-18finaledTR-UTL-0725-01160City permit recordRight-of-Way (ROW) - UtilityCox to proof/pull fiber for 920' for catv commercial business tieComplete
2020-03-16finaledT20RW01660City permit recordROWPLACEMENT OF NEW CONDUIT/FIBER BY MEANS OF BORING AND TRENCHING (371') FOR AT&T SMALL CELL LOCATED AT 6149 S PALO VERDE RD (TUC30_062_A). BUS STOP IN THE AREA, CONTACT SUN TRAN, BEA PAULUS AT 520-206-8826 AND/OR CHRISTINA ROCK AT 520-206-8934 FOR COORDINATION. MAINTAIN PEDESTRIAN AND BUS ACCESS AT ALL TIMES. FIELD ADJUSTMENTS MAY BE REQUIRED. ALL AERIAL WORK MUST BE A MINIMUM OF 16-FT HIGH. REPAIR ALL LANDSCAPING DISTURBED. THIS INCLUDES IRRIGATION, PLANTING,S GROUNDCOVER AND HARDSCAPE. GOOD HOUSEKEEPING MEASURES SHALL BE PRACTICED DURING WORK AND CONSTRUCTION.Final
2020-01-23finaledT20RW00405City permit recordROWTEP WILL BE WORKING IN ROW TO SET NEW SINGLE PHASE OVERHEAD TRANSFORMER ON POLE #81 AND INSTALL UG CONDUCTOR IN CUSTOMER PROVIDED DUCT UNDERGROUND. WILL COMPLETE THE INSTALLATION OF A NEW SECONDARY PEDESTAL AND SET NEW METER. PERMIT VALID ONLY WITHIN CITY RIGHT-OF-WAY. ADDRESS ON APPLICATION: 6149 S PALO VERDE RDFinal
2019-02-11finaledT19RW00763City permit recordROWFishel to expose conduit to remove and replace bad cable that supports businesses in area. Fishel will be trenching 100 ft. in dirt South to existing pedestal on N/B Palo Verde Rd. front of 6161 trenching to south of building. Also Fishel would need access to the man hole located southwest corner of S. Palo Verde and Hemisphere Loop for the removal / install of cable.Final
2018-11-05finaledT18OT01152City permit recordC-OF-OC OF OC of o
2018-11-02T18CM08784City permit recordCommercial BuildingTI: WAREHOUSECanceled
2018-10-18expired 2019-10-29T18FC00853City permit recordFire ConstructionFire Alarm & Detection Systems - INSTALL NEW SPRINKLER MONITORING SYSTEM; Fire Alarm Systems - Monitor OnlyExpired
2018-09-28finaledT18OT01027City permit recordFence / wall1- NON-ILLUM WALL SIGNFinal
Show 24 older records
Permit history for this parcel — remaining 24 records
DateRecordWhatStatusValue
2018-09-06finaledT18CM07014City permit recordCOMBOTI: STORAGE RACKSFinal
2018-08-20expired 2019-05-15T18CM06527City permit recordCOMBOFIRE PUMP ROOM FOR SPRINKLER SYSTEMExpired
2018-08-17finaledT18CM06495City permit recordCOMBONEW METER FOR SITE LIGHTINGFinal
2018-08-15finaledT18FC00678City permit recordFence / wallADD NEW 500 GALLON DOUBLE WALL TANK WITH OUTSIDE FILL AND VENTING PER IFC 2018Final
2018-07-10expired 2019-08-13T18FC00564City permit recordAddition / alterationAutomatic Fire Extingshing Sys - Add new 10" Fire line tap, new diesel driven fire pump, new 25.2k ESFR Sprinkler Heads to an existing building with an existing Fire Sprinkler System; Commercial Fire Sprinkler Systems - Modification of heads: 760; Commercial Fire Sprinkler Systems - Underground Fire Line Supply; Commercial Fire Pumps and Related Equipment - New Pumps: 1; Additional Inspections: 1Expired
2017-06-23finaledT17FC00519City permit recordFIRECONSSUITE C ADD FOUR (4) NEW PENDENTSFinal
2017-05-12finaledT17CM03775City permit recordCOMBOSEPARATE SERVICE LOADSFinal
2017-05-12finaledT17CM03780City permit recordCOMBOOFFICEC of o
2015-12-08expired 2016-08-22T15CM08625City permit recordCOMBOINSTALL 4' OPENING TO CONRETE TILT;COMMExpired
2014-12-12finaledDP14-0237City permit recordDevelopment PackageSITEComplete
2011-03-15expired 2011-10-11T11BU00338City permit recordBUILDREPLACE 3 INTERIOR SUPPORT COLUMNSExpired
2010-06-24finaledT10OT01382City permit recordSIGN18566Final
2010-04-16finaledT10OT00825City permit recordSIGN18195Final
2006-12-06finaledT06CM06194City permit recordCOMBOTI:WAREHOUSEC of o
2004-06-09finaledT04BU01399City permit recordSPKLRSPRINKLER:RELOCATE & ADDFinal
2004-03-11expired 2008-11-29T04CM01152City permit recordCOMBOAIR TANK W/STRUCTURAL CALCClosed
2003-12-26finaledT03BU03209City permit recordSPKLRFIRE SPKR:ADD 12Final
2003-10-30expired 2008-11-29T03CM05159City permit recordCOMBOTI:OFFICEClosed
2003-06-16T03EL01160City permit recordELECTELECTRIC:TO FEED PROPANE TANKWithdrwn
2002-08-06finaledT02OT01193City permit recordSIGNSIGN:4305Final
2001-06-26expired 2001-08-25T01EX00705City permit recordEXCAVEXCAV:80 LFClosed
2001-06-21finaledT01EL01620City permit recordELECTNEW SERVICE: T0 3000AMPFinal
2001-05-01finaledT01BU01217City permit recordSPKLRFIRE:SPKR ADD 14Final
2000-10-16finaledT00ME01144City permit recordMECHPRESSURE VESSEL INSPECTION: TUC-23429, 23432, 23431, 23430Final

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (7)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 7 of 7 records
DateRecordWhatStatus
2014-02-03T14DV00621Code enforcement caseFireComplian
2012-09-21T12DV08893Code enforcement caseVegetationComplian
2010-10-05finaledT10FR02040Code enforcement caseCode enforcement caseComplete
2008-11-18finaledT08FR04361Code enforcement caseCode enforcement caseComplete
2008-10-01T08FR03403Code enforcement caseCode enforcement caseField
2007-08-10T07DV07559Code enforcement caseCode enforcement caseNoverify
2005-01-21finaledT05FR00092Code enforcement caseCode enforcement caseComplete

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 14029052C — 32 permits on file from 2000 to 2025 (9 combo, 3 row, 3 sign, 3 spklr) and 7 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.