Electrical permit history — 6161 S Palo Verde Rd

6161 S Palo Verde Rd, Tucson — built 1996, with 37 permits on record. Review electrical, HVAC and remodel history with links to official records.

Electrical Property Screening Report · Commercial property

6161 S Palo Verde Rd

A screening report for electrical planning, assembled from public-record indicators. It is not an official record and every figure in it should be verified against the issuing agency before it is relied on.

Verify parcel data at official source ↗

Built 1996 — 1990s commercial stock · last permitted panel/service work 2001 (finaled)

Is it time to upgrade?

  • Electrical service & distributionFinaled permit foundLast permitted 2001 (25 years ago). Worth reading the permit itself: it names the service but does not read as an increase in capacity, so this may have been a like-for-like replacement rather than an upgrade. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. T01EL01620 — NEW SERVICE: T0 3000AMP
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2018 addition / alteration permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyLikely dueA newer 2018 permit for the same system is recorded as “Expired” — The permit expired without a confirmed final status. The permit description states “Fire Alarm & Detection Systems - INSTALL NEW SPRINKLER MONITORING SYSTEM; Fire Alarm Systems - Monitor Only”. Last permitted 2004 (22 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T04BU01399 — SPRINKLER:RELOCATE & ADD
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitized. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    A finaled 2001 panel/service permit is on record for this parcel, which makes it unlikely the original 200 A equipment is still in place. That is a permit record, not an inspection — verify the installed rating and the panel brand on site before sizing anything new. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    Gear in this age range is usually still supported but is due for infrared scanning and torque verification if that has not been done recently. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Routine

    A trade permit was pulled in 2018. Trade permits cover electrical, plumbing, and mechanical work individually, so some permitted trade work has been done here since.

Solar and energy potential

Roof footprint
≈ 131,372 sq ft (county building-footprint layer)
Usable for solar, planning estimate
≈ 92,000 sq ft (~70% after setbacks, rooftop equipment and access paths)
Array that could fit
on the order of 1,010 kW — roughly 2,530 panels (low-tilt ballasted rows, 400 W class modules)
Estimated annual production
≈ 1,660,000 kWh (PVWatts, Tucson sun, low-tilt south)
Energy-charge offset at TEP commercial rates
$133,000–$216,000 a year (8–13¢/kWh energy + power-supply charges, by season and rate class)

Planning-level arithmetic on the roof area above — not a shading study, a structural review or a design. The offset assumes the building uses the power as it is generated; TEP pays far less (its export rate is about 5¢/kWh) for surplus sent to the grid, so the load profile decides the real value. The 30% federal credit (§48E) still applies to commercial systems placed in service by the end of 2027 — projects that began construction by July 4, 2026 have longer; confirm timing with a tax adviser.

TEP grid capacity — mapped saturation areaThis property sits within about half a mile of “I-10 and Valencia Rd”, one of 11 areas TEP has mapped as saturated with distributed generation (customer solar) relative to circuit capacity. On a saturated circuit, new solar or battery systems can trigger supplemental utility review before interconnection is approved — and a large new load such as DC fast charging or process equipment is worth a capacity conversation with TEP before a site plan hardens. The boundary here is approximate, digitized from TEP’s map of the area (PDF, July 2020); TEP’s own interconnection screening is the authority, and circuit status can have changed since the maps were published.

Get a commercial solar & switchgear analysis

See the property

Satellite imagery © Google. Imagery can predate recent work and shows nothing about what is inside — context, not evidence.

Flood and drainage

The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.

The record behind this read

Parcel
14029052C
Year constructed
1996 (assessor record)
Permitting authority
Tucson
Zoning
I-1
Property type
Warehousing
Building area
128,941 sq ft
Service on record
City records show the 2001 permit was finalized; the permit description states “NEW SERVICE: T0 3000AMP”.

The building area above comes from the Pima County Assessor’s record, as we read it on 28 Jan 2026. Each other row names its own source.

The most recent permitted work on this parcel was in 2025. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What this means for work here

Informational public-record summary — not engineering, inspection, valuation or purchasing advice, and not the official record.

The most recent permitted work on this parcel was in 2025. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What that reading rests on. The issuing offices hold 37 building permits for this parcel dated between 1997 and 2025. By category the work is trade permit (8), addition / alteration (7), fire automatic extinguishing system (6) and permanent sign (5). 23 of them carry a final inspection; the other 14 were issued, expired or are still open, which is not the same as work completed. There are 2 code-enforcement cases recorded against the parcel, all of them closed. We do not reproduce complaint text — it routinely names people with no connection to the property.

Go straight to the records

Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.

Read the records yourself. We republish selected facts and record numbers so you can find the file; the issuing agency’s record controls. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 14029052C. Permit and parcel information courtesy of the City of Tucson and Pima County; their files are the official record and control over anything summarized here.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.

In the public record: All industrial property · Commercial property in 85706 · Commercial & industrial reports · Homes in 85706 · Permit data by neighborhood

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

What the flood note is not. The flood zone shown is FEMA’s National Flood Hazard Layer — the federal insurance map. Local floodplain mapping is not reproduced here; use the authority’s own map, linked above. Nothing here is a floodplain determination, an elevation certificate, or a substitute for one. A parcel can straddle a boundary, and a Letter of Map Amendment can remove a structure the map still covers. For a determination, ask the floodplain administrator for the jurisdiction named above; for a design that has to satisfy one, that is work we do.

How this property compares nearby

Properties on S PALO VERDE RD hold 132 City permits on record, 41 of them since 2022.

Computed from the same public records as this report — counts and years, not an appraisal.

Complete permit record (39 entries)

Every permit and case we hold for this parcel, newest first. Each number links to the official file.

YearNumberTypeStatus
2025recordRight-of-Way (ROW) Permit - UtilityComplete
2018T18SA00523Zoning ComplianceComplete
2018T18OT01152Commercial Addition/Alteration PermitComplete
2018T18CM08784Commercial Addition/Alteration PermitCanceled
2018T18FC00853Fire Alarm System PermitExpired
2018T18OT01027Permanent Sign PermitComplete
2018T18CM07014Commercial Addition/Alteration PermitComplete
2018T18FC00678Other IFC Construction PermitComplete
2018T18CM06495Commercial Trade PermitComplete
2018T18CM06527Commercial Addition/Alteration PermitCanceled
2018T18FC00564Fire Automatic Extinguishing System PermitExpired
2017T17CM03775Commercial Trade PermitComplete
2017T17FC00519Fire Automatic Extinguishing System PermitComplete
2017T17CM03780Commercial Addition/Alteration PermitComplete
2015T15CM08625Commercial Trade PermitCanceled
2015DP14-0237Development PackageComplete
2014T14SA00336Zoning ComplianceComplete
2014T14SA00319Zoning ComplianceApproved
2014T14PRE0028Pre-Application ConferenceCanceled
2014T14DV00621FIRE AT COMMERCIAL BUILDINGCOMPLIAN
2012T12DV08893WEEDSCOMPLIAN
2012T12SA00288Zoning ComplianceComplete
2011T11BU00338Commercial Trade PermitCanceled
2010T10OT01382Permanent Sign PermitComplete
2010T10OT00825Permanent Sign PermitComplete
2007T07DV07559Permanent Sign PermitClosed - Unfounded
2006T06CM06194Commercial Addition/Alteration PermitComplete
2005T05BA00499Stormwater BasinApproved
2004T04BU01399Fire Automatic Extinguishing System PermitComplete
2004T04CM01152Commercial Trade PermitCanceled
2003T03BU03209Fire Automatic Extinguishing System PermitComplete
2003T03CM05159Commercial Addition/Alteration PermitCanceled
2003T03EL01160Commercial Trade PermitWithdrawn
2002T02OT01193Permanent Sign PermitComplete
2001T01EL01620Commercial Trade PermitComplete
2001T01BU01217Fire Automatic Extinguishing System PermitComplete
2000T00ME01144Commercial Trade PermitComplete
1997T97BU01161Commercial Fence/Wall PermitCanceled
1997T97BU00865Fire Automatic Extinguishing System PermitComplete

prints this report — permits, comparisons and sources — as a clean document

How this report was built

This is a reading of public records for parcel 14029052C — 37 City permits on file from 1997 to 2025 and 2 code enforcement cases — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive, whose records reach back to the mid-1990s. Some records were still not read for this snapshot: City permit records before the mid-1990s were never fully digitized. The construction year, living area on this page come from our saved copy of the Assessor’s own published data file (dated 2026-01-28). The sewer connection file and the flood map were not read for this snapshot. Absence of a permit here is NOT evidence work was never permitted — it may predate the digitized record or sit in a system this snapshot did not read. Public records snapshot taken 2026-08-22.

The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.